PNI HP6500 CB Radio User Manual

June 6, 2024
PNI

PNI HP6500 CB Radio

PNI HP6500-CB-Radio

Introduction

Thank you for your choose and buy the Nanfone CB Radio. In order to make your CB Radio to use in the best condition, please read this manual in detail.PNI Escort HP 6500 is a small, simple operation and convenient vehicle CB Radio which has good performance.

Feature:

  • Up/down keys on the microphone
  • Scan channel
  • LCD display
  • Auto ASQ/SQ adjustable
  • RF GAIN
  • External Speaker

Installation instructions

Check the materials before the installation, car charger is connected to the car’s 12 v power supply socket, the radio’s positive and negative electrodes is connected to the car chargers. Power supply support 12 V to 13.8 V. Check all wiring are in good condition before starting, ensure do not short circuit, ensure the radio can boot running normally.

Control panel function

Front view

No

| ****

Name

| Short Press Function| Long Press Function
---|---|---|---


| Microphone socket|  |


| ****

A/F

| AM/FM Mode Switch| ****

Scan Function

③| LCD Display|  |


| Power On/Off Volume|  |

| Channel UP/DOWN

select

|  |
---|---|---|---


| EMG(Emergen cy Channel )| 9/19 Channel Switch|


| ****

RFG

| Enter RF GAIN Model|


| SQ/ASQ

Function Switch

| Enter SQ (ASQ) Level Switch| Switch To ASQ Mode

Operation

Power On/Off the radio

  1. Turn VOL switch clockwise to power on the radio, the LCD full screen display after spectrum model 1 s into the channel
    state.

  2. Turn the VOL Knob counterclockwise, until it clicks. The radio is powered off.

Volume Control
Turn clockwise to increase volume, turn counterclockwise to decreases volume.

Channel Selection

  1. Shortly press microphone【UP】or【DOWN】to change the working channel.
  2. Hold microphone 【UP】or【DOWN】to change working channel fast.

Squelch level control

  1. Shortly press【SQ】, until LCD shortly displays SQ and then display X.X。X.X stands for the SQ level
     | SQ off
    ---|---
    0.1| Lowest SQ level
    …| …
    2.8| Highest SQ level
  2. Press microphone【UP】/【DOWN】shortly to change SQ level.
  3. Hold microphone【UP】/【DOWN】to change the SQ level fast.
  4. Hold【SQ】or wait for 3 seconds to store and exit.

ASQ control(9 levels)

  1. Hold【SQ】key, until LCD displays AQ, the ASQ function is turned on. The LCD will display A.X。X stands for the
    ASQ level。
A.1 Lowest ASQ level
A.9 Highest ASQ level
  1. Shortly press microphone【UP】/【DOWN】to change ASQ level.
  2. Hold microphone【UP】/【DOWN】to change ASQ level fast.
  3. Hold【SQ】or wait for 3 seconds to store and exit.

Modulation Type

Shortly press【A/F】key to switch between AM/FM mode and the LCD displays the selected mode.

RF GAIN control

  1. Shortly press【RFG】key,LCD displays R and the present RF GAIN level flashes.
  2. Shortly press microphone【UP】/【DOWN】to change the level.
  3. Shortly press【RFG】key to exit RF GAIN level control.

Emergency Channel

  1. Shortly press【EMG】 key to choose CH9,the channel number flashes.
  2. Shortly press 【EMG】key again to choose CH19,the channel number flashes.
  3. Shortly press【EMG】key third time to return to last normal channel.

Key Lock

  1. Hold【EMG】key for over 2 seconds to lock the keys, LCD displays “LC”.
  2. Hold【EMG】for over 2 seconds again to unlock the keys, LCD displays “OF”.

Scan Function

  1. Hold【A/F】to start scan function,LCD displays“SC”.
  2. Press microphone【UP】/【DOWN】can choose scanning clockwise or counterclockwise.
  3. Press【A/F】or【PTT】key to exit scan function.

Changing the CB-Standard

  1. Hold【A/F】while powering the radio on, until LCD displays the norms.
  2. Press microphone【UP】/【DOWN】to choose wanted Norms.
  3. Power off and power on again
Standard Channels Fequency Range
EU 40FM/40AM 26.965-27.405MHZ
CE 40 FM 26.965-27.405MHZ
UK 40 FM 27.60125-27.99125MHZ
PL 40FM/40AM 26.960-27.400MHZ
--- --- ---
I2 34FM/34AM 26.965-26.865MHZ
DE 40FM/40AM 26.965-27.405MHZ
80FM 26.565-26.955MHZ
IN 27FM/27AM 26.965-27.275MHZ

Restore factory default

1.Hold【SQ】key while powering the radio on, until the LCD
displays “rt”.
2. All channel and function setting will resume factory default after above operation.

FCC Statement:

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 50cm between the radiator&your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PNI User Manuals

Related Manuals