namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
- October 27, 2023
- NAMRON
Table of Contents
namron 4512737 Touch Zigbee 16A Thermostat Instruction
INSTRUCTION MANUAL
Namron termostat touch ZigBee 16A
Technical data
Installation
- a. Installation must be done by a qualified electrician.
- b. Power supply must be turned off during installation.
Wiring diagram
Mounting
- Remove the display unit and front cover by using a small screwdriver.
- Insert the wires into the correct terminals as presented in the wiring diagram above. The suggested wire-stripping length is 8-10mm.
- Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).
Symbol overview
Settings Menu
How to enter the settings menu:
- Under Home Interface, meanwhile, the device is in OFF mode same time for over 5 seconds to enter Settings Menu. Press and hold the up and down buttons at the same time for over 5 seconds to enter Settings Menu.
- The short press moves up and down button to select a settings item, then short press button F to enter the selected item.
- The settings menu includes the Preview menu, Zigbee settings, Schedule, Monitor settings, Time/Date settings, and Other settings.
Time Setting
Select TIME/DATE on Home Interface to enter into the TIME/DATE SET
interface as follow:
Short press the button to select the item would like to modify, then short press the move up and move down buttons to modify the value of a selected item, then short press the button to save and quit, short pressing button only quits without saving.
The device Time Cluster is the client, if the bound device supports the local
time of Time Cluster, the device will acquire local time from the bound device
spontaneously under 3 situations: acquire after this device is added to a
network, acquire when the device is already added to a network and power is
reset, acquire every 24 hours.
Standby Interface
If the device operation mode is set to any other mode except OFF Mode, and there is no operation within 2 minutes, the device will go to this standby interface. Once the device goes to the standby interface, if the Display Auto Off function is enabled and there is no operation within 30 seconds, the display will go off automatically. If the device operation mode is set to OFF Mode, and there is no operation within 2 minutes, the display will go off automatically.
Preview interface
On Home Interface, the user can enter PREVIEW consumption, date, floor
temperature, etc. interface, the interface will display some basic
configurations, energy
Control Mode
Short press the button on Home Interface to switch operation modes: the icons of Away, Auto, Manual, Drying, and Off modes will be displayed alternatively for 3 seconds and the last displayed mode will be selected, or just short press the F button to select the desired mode when the modes’ icon displayed alternatively. Press and hold the button on the Home interface for over 3 seconds to select Away mode directly, then Press and hold the button for 3 seconds to quit Away mode.
Away Mode Schedule
Users can set the time to leave home and time to go home according to their
requirements of themselves, and set how the device will control the
temperature during this period.
- If away mode has already been activated, the end time for away mode is valid, the device will execute the Away Mode Temperature Schedule before the end time.
- If away mode has already been activated, the values of the end time for away mode are set as 0, the device will always execute the current set temperature with no time limitation. The device will consider the mode as antifreeze mode, the recommended temperature setting is 4-10℃, and the factory default setting is 6℃.
Auto Mode Schedule
When Auto Mode Schedule is valid, the device will control according to the set
temperature of the schedule. For instance, if the user would like to keep the
room temperature at 18 degrees Celsius during 18:00-23:00 every Monday, and
keep the room temperature at 20 degree Celsius after 22:30 every Monday, then
the user can set the schedule by himself.
Schedule setting method 1: user can enter into follows: schedule on System Setting Interface, the schedule interface is as.
Short press the button to select “Auto Schedule”, then short press the button to enter into Auto Mode Schedule weekly setting interface.
Schedule setting method 2: on System Setting Interface, meanwhile the device is under the Auto Mode button to enter into Auto Mode Schedule weekly setting interface quickly:
On the Auto Mode Schedule weekly setting interface, use buttons and week as follows: to enter into the schedule setting of a certain week as follows:
On the Auto Day Schedule interface, short-press the button to select the time
or temperature that you would like to modify, then short-press move up and
move down buttons
Value, then short press the button to save and quit, short pressing button
saving. to modify only quits without.
For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error reminder “Time setting error!!!”. The default time schedules are as follows:
Monday-Friday
| 7:30,24C-12:00,20C|
Saturday-Sunday
| 7:30,24C-12:00,20C
---|---|---|---
18:00,16C-22:30,18C| 18:00,18C-22:30,18C
Manual Mode: the device will control the heating system according to the
current set temperature. The temperature can be set by a move up and move down
button on the Home interface or configured by Zigbee gateway.
Dry Mode Schedule
For example, in order to quickly dry the water on the floor of the bathroom,
the device can be set to quickly heat in a short time to dry the floor. Enter
the configuration interface as follows:
Duration: set how long the dry mode lasts, which can be configured
through the proprietary attribute DryTime (0x1006) of Thermostat Cluster
(0x0201), the configurable range is 5-100 minutes.
After Mode: set the mode after the drying mode ends, which can be
configured through the proprietary attribute ModeAfter-Dry (0x1007) of
Thermostat Cluster (0x0201).
Remain: shows the remaining time of the drying mode For configuration method
and modification, please refer to Automatic Mode (Energy Save Mode) Schedule:
Off Mode
This mode means that the device is under idle status.
Window Open Detect (disabled by default)
Once the device is powered on and stable, referring to the room temperature
sensor, if the temperature decreases to the threshold of this setting, the
window open mark will be enabled, the relay will be forced to turn off to save
energy, then the icon will appear. After the window open mark is enabled, if
the temperature increases to the threshold of this setting in 3 minutes, the
window open mark will be disabled. Once the window open mark is enabled, it
will be disabled after 10 minutes, and the device will keep the current
working mode. This value can also be configured through the proprietary
attribute WindowOpenCheck (0x1009) of Thermostat Cluster (0x0201), 0 means
this function is disabled.
Note: this function will work better when the device is installed beside
the window or door.
Monitor Set
|
| The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows:
Short press button to select the item would like to modify, then short press move up and down buttons to modify value of selected item, then short press F button to save and quit, short pressing
button only quits without saving.
---|---|---
Over-current Alarm
|
16A by default
| If current is over the set value, the relay will be forced to off by the device, and the state will be reported to the gateway. The over current alarm function can be disabled, which can be set directly through the device. Or can be configured through the ACAlarmsMask and ACCurrentOverload of Electrical Measurement (0X0B04), for details please refer to the configuration value .
Note: When over current alarm is triggered, the beeper will beep, to cancel the alarm, just press and hold button for over 3 seconds or reset power of the device. After cancel manually, the relay will show heating forbidden icon within 120 seconds, but other operations are allowed.
---|---|---
Max floor temp| 27°C by default
|
This function is similar to the function of “Internal Over Heat Protection” described in chapter 4.9. When the control type is configured as “Room+Floor sensor”, this function will be valid: The alarm will be triggered when the floor sensor temperature > Max floor temp, the relay will be forced to off by the device, and the state will be reported to the gateway. The following indication figure will prompt on the display.
After the floor sensor temperature < (Max floor temp – Hysteresis), the alarm will be cancelled automatically and the device will restore to previous operation mode.
To cancel the alarm manually, just press and hold button for over 3 seconds, but the relay will show heating forbidden icon within 120 seconds and the alarm will not be triggered again, after 120 seconds expire, the device will restore to previous operation mode and continue to detect alarm temperature.
This function can be disabled, which can be configured directly through the device, or can be configured through the attribute Max floor temp (0x2001) of Thermostat Cluster (0x0201), when this value is set as 0, this function is disabled.
Hysterersis
|
0.5°C by default
|
To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature, which will cause that the controller may keep switching on/off the relay. Here hysterersis enables the controller to control the relay only when the sensor temperature is lower than the set temperature minus the hysteresis value , this value can be set.
For instance, when hysterersis is set as 0.5 degree, then only when current sensor temperature < (the set temperature – 0.5 degree), will the controller heat.
This value can also be configured through the proprietary attribute Hysterersis (0x100A) of Thermostat Cluster (0x0201).
Key Vibration Set
|
OFF by default
|
Set the level of vibration sensor under the buttons or buzzer level. OFF: vibration or buzzer off Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level.
This level can also be configured through the proprietary attribute
ButtonVibrationLevel (0x1001) of Thermostat Cluster (0x0201).
Display Brightness Set
|
Mid Level by default
|
The OLED display brightness when operate the device. High Level, Mid Level, Low Level.
This brightness can also be configured through the proprietary attribute OperateDisplayLcdBrightness (0x1000) of Thermostat Cluster (0x0201).
Display Auto Off
| | On the Home Interface, press and hold both Fand buttons for over 10S, during the process, the icon will flash slowly, the
Display Auto OFF function can be enabled or disabled, when the function is enabled, the icon will be displayed, otherwise the icon will not be displayed.
This Display Auto Off can also be configured through the propri- etary attribute 0x100B of Thermostat Cluster (0x0201).
---|---|---
Display Temperature Set
|
Home Temp by default
|
This parameter defines which sensor temperature will be displayed on Home page.
Floor Temp: floor temperature (external sensor) . Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute TemperatureDisplay (0x1008) of Thermostat Cluster (0x0201).
Other Set
|
| Select OTHER SET on Home Interface to enter into OTHER SET interface as follow:
Short press button to select the item you would like to modify, then short press move up and down buttons to modify value of selected item, then short press button F to save and quit, short pressing button only quits without saving.
Temperature Compensation
|
0 by default
| The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do
temp compensation to room sensor and floor sensor. Compensation range is -5 ~ +5°C, stepping is 0.5°C.
This value can also be configured through the attribute Local TemperatureCalibration (0x0010) of Thermostat Cluster (0x0201), and through the proprietary attribute FloorSensorCalibration (0x1005) of Thermostat Cluster (0x0201).
Re-power Status
|
last status by default
| Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure after power on again.
If set as “default”, device will go to default mode after power on again.
This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat Cluster (0x0201).
Internal Over Heat Protection
| | To ensure the safety of the device, if the internal temperature of the device (not displayed on the interface) is over a certain value during heating process, the device will execute a short temporary action to turn off the relay, and the icon will appear on the interface, after the temperature decreases to a certain value, the device will recover to work.
Child Lock
| | On the Home Interface, press and hold both Fand buttons for over 10S, the Child Lock can be enabled or disabled, when the
Child Lock is enabled, the icon will appear at the upper right corner, otherwise the icon will not appear.
This Child Lock can also be configured through the attribute KeypadLockout (0x0001) of Thermostat Cluster (0x0201).
Zigbee Configuration Introduction
Select Network Set on Home Interface to enter into the Zigbee network management interface as follow:
Adding to a Zigbee Network
Operate your Zigbee gateway to add device, select “Add”, then short press
button F , the device will search network and try to join, “Status” will show
“Inclusion…”. If there is no response from a gateway, or adding failed,
“Status” will show “Fail”. If added successfully, “Status” will show
“Inclusion OK” and device ID.
Removing from a Zigbee Network
Operate your Zigbee gateway to remove device, Select “Remove”, then short
press button , the device will send out removing request, “Status” will show
“Exclusion…”. If there is no response from a gateway, or removing failed,
“Status” will show “Fail”. If removed successfully, “Status” will show
“Exclusion OK” and device ID will be showed as 0.
The device will be removed from the network and all parameters will be
restored to factory default setting, all bindings will be cleared.
Factory Reset (Reset)
Factory resetting will remove the device from the Zigbee network and all
parameters will be restored to factory default setting, all bindings will be
cleared.
Select “Reset”, then short press button F , the device will start reset,
“Status” will show “Reset…”. If exclusion failed,
“Status” will show “Fail”. If reset successfully, “Status” will show “Reset
OK”.
Configure Device Operation Mode through Zigbee Since Zigbee does not have away
mode, the attribute Occupancy (occupied or unoccupied) of Thermostat (0x0201)
and attribute Occupancy of received OccupancySensing (0x0406) are required to
judge whether it is away mode.
-
if the device receives other devices’ or the gateway’s report: the Bit 0 of the value of attribute Occupancy (0x0000) of OccupancySensing Cluster (0x0406) is 1, which means occupied, then the operation mode of the thermostat, the attribute SystemMode(0x001c)=0x04(heat) of Thermostat (0x0201), meanwhile the value of attribute Occupancy
(0x0002) of Thermostat (0x0201) is 0. It means the Away Mode is activated, and the thermostat UI will display. -
if the gateway send command to modify the attribute SystemMode(0x001c) of Thermostat (0x0201), the thermostat will quit Away Mode. Meanwhile the value of attribute Occupancy (0x0002) of Thermostat (0x0201) is 1.
-
The proprietary attribute 0x2002(Manufacturer Code=0x1224) of the cluster 0x0201 can be modified to configure whether it is away mode or at home.
Note: Away Mode uses attribute UnOccupiedHeatingSetpoint to set temperature.
Other modes uses attribute OccupiedHeatingSetpoint to set temperature.
Zigbee Interface
The thermostat provides 3 Zigbee application endpoints:
Endpoint | Profile | Application |
---|---|---|
0(0x00) | 0x0000(ZDP) | ZigBee Device Object (ZDO) – standard management |
features
1(0x01)| 0x0104(HA)| Device ID is 0x0301(Thermostat ).
2(0x02)| 0x0104(HA)| Device ID is 0x0007(OTA).
242(0xF2)| 0xA1E0(GP)| Device ID is 0x0021(GreenPower).
Application Endpoint #0 –ZigBee Device Object
- Application profile Id 0x0000
- Application device Id 0x0000
- Supports all mandatory clusters
Application Endpoint #1 –Thermostat
Cluster | supported | Description |
---|
0x0000
| ****
server
| Basic
Provides basic information about the device, such as the manufacturer ID, vendor and model name, stack profile, ZCL version, production date,
hardware revision etc. Allows a factory reset of attributes, without the device leaving the network.
0x0003
| ****
server
| Identify
Allows to put the endpoint into identify mode. Useful for identifying/locating devices and required for Finding & Binding.
0x0004
| ****
server
| Groups
Allows adding this endpoint to one or more groups. Afterwards the endpoint can be addressed using the group address. This is also a prerequisite for
scenes. You may also query group membership and delete group associations.
0x0005
| ****
server
| Scenes
Allows storing one or more scenes per group, where each scene consists of a pre-set on/off state value. You may either store the current values as a
scene, or provide scene settings when adding a scene, or delete scenes.
0x0201| server| Thermostat
0x0702| server| Simple Meter
0x0b04
| ****
server
| Electrical Measurement
Measuring power, voltage, current
0x0009
| ****
server
| Alarm
Device related alarm
0x0406| client| Occupancy Sensing
0x000a| Server| Time
0x0204| server| Thermostat User Interface Configuration
-
Basic -0x0000 (Server)
-
Attributes supported:
Attribute | Type | Description |
---|
0x0000
| INT8U,
read-only
| ZCLVersion
0x03
0x0001
| INT8U ,
read-only
| ApplicationVersion
This is the firmware version number of the application
0x0002
| INT8U ,
read-only
| StackVersion
0x0003
| INT8U ,
read-only
| HWVersion
Hardware version 1
0x0004
| string,
read-only
| ManufacturerName
“NAMRON AS”
0x0005
| string,
read-only
| ModelIdentifier
“4512737 & 4512738”
0x0006
| string,
read-only
| DateCode
NULL
0x0007
| ENUM8,
read-only
| PowerSource
Device power supply, fixed value 0x01 Mains (single phase)
0x0008
| ENUM8,
read-only
| GenericDevice-Class
0XFF
---|---|---
0x0009
| ENUM8,
read-only
| GenericDevice-Type 0XFF
0x000A
| octstr
read-only
| ProductCode 00
0x000B
| string,
read-only
| ProductURL NULL
0x4000
| string,
read-only
| Sw build id 6.9.1.0_r4
Command supported:
Command | Description |
---|
0x00
| Reset to Factory Defaults Command
On receipt of this command, the device resets all the attributes of all its
clusters to their factory defaults. Note that networking functionality, bindings, groups, or other persistent data are not affected by this command.
-
Scenes 0x0005 (Server)
-
Attributes supported:
Attribute | Type | Description |
---|
0x0000
|
int8u,
read-only
| SceneCount
Holds the total number of scenes (across all groups) currently stored on the device.
0x0001
|
int8u,
read-only
| CurrentScene
If the SceneValid attribute is true, this attribute, together with the CurrentGroup attribute,indicates the currently active scene.
0x0002
|
int16u,
read-only
| CurrentGroup
If the SceneValid attribute is true, this attribute, together with the CurrentScene attribute,indicates the currently active scene.
0x0003
|
bool,
read-only
| SceneValid
If true, the scene identified by CurrentGroup and CurrentScene is currently active, i.e. all device attribute values match the values in the scene field set.
0x0004
| bitmap8 , read-only| NameSupport
Command supported:
Command | Description |
---|---|
0x00 | Add Scene |
Adds a scene with or without a scene field set
0x01| View Scene
Returns the scene field set, name and transition times for a scene.
0x02| Remove Scene
Removes a scene from the scene table.
0x03| Remove All Scenes
Removes all scenes that belong to a particular group.
0x04
| Store Scene
Stores the device’s current state as a scene or updates a previously stored scene accordingly
---|---
0x05
| Recall Scene
Reverts the device’s current state using the values from the previously stored fieldset.
- Groups-0x0004 (Server)
- Attributes supported:
Attribute | Type | Description |
---|
0x0000
| bitmap8, read-only| NameSupport
0, not supported
Command supported:
Command | Description |
---|
0x00
| Add Group
Adds the endpoint to a group.
0x01
| View Group
Determines whether the device belongs to a group and returns the group name, if supported
0x03
| Remove Group
Removes this endpoint from the specified group. Also removes all scenes that refer to this group.
0x04
| Remove All Groups
Removes this endpoint from all groups. Also removes all scenes that refer to any of the existing groups.
0x05
| Add Group if Identifying
Adds this endpoint to the group, if the endpoint is identifying.
- Thermostat-0x0201(Server)
- Attributes supported:
Attribute | Type | Description |
---|
0x0000
| int16S ,
read-only
| reportable LocalTemperature Attribute
This is room temperature, the maximum resolution this format allows is 0.01 ºC.
0x0001
| int16S ,
read-only
| reportable OutdoorTemperature
This is floor temperature, the maximum resolution this format allows is 0.01 ºC.
0x0002
|
bitmap8 , read-only
| Occupancy
When this flag is set as 1, it means occupied, OccupiedHeatingSetpoint will be used, otherwise UnoccupiedHeatingSetpoint will be used.
0x0010
|
Int8S ,
reportable
| LocalTemperatureCalibration
Room temperature calibration, range is -30-30, the maximum resolution this format allows 0.1°C. Default value: 0
0x0011
| int16S ,
reportable
| OccupiedCoolingSetpoint
This system is not invalid.
0x0012
|
int16S ,
reportable
| OccupiedHeatingSetpoint
Range is 0-4000,the maximum resolution this format allows is 0.01 ºC. Default is 0xbb8(30.00ºC)
0x0014
|
int16S ,
reportable
| UnoccupiedHeatingSetpoint
Range is 0-4000,the maximum resolution this format allows is 0.01 ºC. Default is 0x258(6.00ºC)
0x001B
| Enum8,
reportable
| ControlSequenceOfOperation
Set device supported operation type, here only supports Heating Only(0x02)
---|---|---
0x0029
| Map16,
read-only, reportable
| HVAC relay state/ ThermostatRunningState
Indicates the relay on/off status, here only supports bit0( Heat State)
Proprietary Attributes:
Attribute| Type| Manufacturer
code
| Description
---|---|---|---
0x1000
|
ENUM8,
reportable
|
0x1224
| OperateDisplayLcdBrightnesss
OLED brightness when operate the buttons: Value=0 : Low Level
Value=1 : Mid Level(default) Value=2 : High Level
0x1001
|
ENUM8
reportable
|
0x1224
| ButtonVibrationLevel
Key beep volume & vibration level: Value=0 : off(default)
Value=1 : Low Level Value=2 : High Level
0x1002
|
ENUM8
reportable
|
0x1224
| FloorSenserType
Select external (Floor) sensor type: Value=5 : NTC 12K/25
Value=4 : NTC 100K/25 Value=3 : NTC 50K/25 Value=2 : NTC 15K/25
Value=1 : NTC 10K/25 (Default)
0x1003
|
ENUM8
reportable
|
0x1224
| ControlType
The referring sensor for heat control: Value=0 : Room sensor(Default)
Value=1 : floor sensor
Value=2 : Room+floor sensor
0x1004
|
ENUM8
reportable
|
0x1224
| PowerUpStatus
The mode after reset power of the device: Value=0 : default mode
Value=1 : last status before power off (Default)
0x1005
| INT8S,
reportable
|
0x1224
| FloorSenserCalibration
The temp compensation for the external (floor) sensor, range is -30-30, unit is 0.1°C. default value 0
0x1006
| INT8U
reportable
|
0x1224
| DryTime
The duration of Dry Mode, range is 5-100, unit is min. Default value is 5.
0x1007
|
ENUM8
reportable
|
0x1224
| ModeAfterDry
The mode after Dry Mode: Value=0 : OFF
Value=1 : Manual mode
Value=2 : Auto mode –schedule (default) Value=3 : Away mode
0x1008
| ENUM8
reportable
|
0x1224
| TemperatureDisplay :
Value=0 : Room Temp (Default) Value=1 : Floor Temp
0x1009
|
INT8U
reportable
|
0x1224
| WindowOpenCheck
The threshold to detect open window, range is 0.3-8, unit is 0.5ºC,
0 means disabled, default is 0
0x100A
| INT8U
reportable
|
0x1224
| Hysterersis
Hysterersis setting, range is 5-50, unit is 0.1ºC, default value is 5
---|---|---|---
0x100B
| ENUM8
reportable
|
0x1224
| DisplayAutoOffEnable
0, disable Display Auto Off function 1, enable Display Auto Off function
0x2001
| INT8U,
reportable
|
0x1224
| Max floor temp
Floor temperature over heating threshold, range is 0-35, unit is 1ºC, 0 means this function is disabled, default value is 27.
0x2002
| ENUM8
reportable
|
0x1224
| Away Mode Set:
Value=0: not away (default) Value=1: away
Command supported:
Command | Description |
---|
0x0000
| Setpoint Raise/Lower
Increase or decrease the set temperature according to current mode, unit is 0.1ºC
- Simple Meter-0x0702 (Server)
- Attributes supported:
Attribute | Type | Description |
---|
0x0000
| unsigned48 , read-only,
reportable
| CurrentSummationDelivered
Indicates the current amount of electrical energy delivered to the load.
0x0200
| bitmap8 , read-only| Status
Flags indicating current device status, always is 0x00
0x0300
| enum8 ,
read-only
| UnitOfMeasure
The unit of metering data, this is always kWh(0x00)
0x0303
| map8 ,
read-only
| SummationFormatting
The decimal point on the left and right sides of the data, this is always 0x00
0x0306
| bitmap8, read-only| MeteringDeviceType
Metering data type, this is always Electric Metering (0x00)
- Electrical Measurement-0x0b04(Server)
- Attributes supported
Attribute | Type | Description |
---|
0x0000
|
bitmap32 , read-only
| MeasurementType
Indicates the physical entities that this devices is able to measure. Supports only bit0: Active measurement (AC)
0x0505
| int16U ,
read-only, reportable
|
RMSVoltage
Single phase valid voltage, unit is V
0x0508
| int16U ,
reportable, read-only
|
RMSCurrent
Single phase valid current, unit is A
0x050B
| int16S ,
reportable read-only
|
ActivePower
Single phase valid power, unit is W
0x0600
| int16U,
read-only
|
ACVoltageMultiplier
ACVoltageDivisor | ||
---|---|---|
0x0601 | int16U, |
read-only
| Used together with above attributes, the real displayed voltage =
RMSVoltage* ACVoltageMultiplier
| | / ACVoltageDivisor
0x0602
| int16U,
read-only
|
ACCurrentMultiplier
| | ACCurrentDivisor
0x0603| int16U,
read-only
| Used together with above attributes, the real displayed current = RMSCurrent
- ACCurrentMultiplier
| | / ACCurrentDivisor
0x0604
| int16U,
read-only
| ACPowerMultiplier
0x01
| |
0x0605
| int16U,
read-only
| ACPowerDivisor
0x01
Used together with above attributes, the real displayed power = Active Power *
| | ACPowerMultiplie / ACPowerDivisor
0x0800
|
int16U,
| ACAlarmsMask
Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over current will not be detected
0x0802
| int16S ,
reportable read-only
| ACCurrentOverload
Alarms when the current is over a certain value, 0, 10-16, unit is A, for the unit please refer to RMSCurrent, ACCurrentMultiplier, ACCurrent Divisor
Proprietary Attributes:
Attribute | Type | Manufacturer code | Description |
---|
0x0000
|
Int8u,
reportable
|
0x1224
| OverCurrent
Over current value set by the user, range is 0, 10-16, ACCurrentOverload will change spontaneously if this value is modified.
Alarm-0x0009(Server)
Please set a valid value for ACAlarmsMask of Electrical Measurement. The Alarm
Server cluster can generate the following commands
Camden | Description |
---|---|
0x00 | Alarm: |
The alarm code of Electrical Measurement is 0, Proprietary command, Manufacturer code=0x1224
Camden | Description |
---|---|
0x00 | Room air temperature overheat, not alarm code |
Time-0x000A(server)
The Time cluster is a general cluster for time it is based on a UTC time in
seconds since 0 hrs 0 mins 0 sec on 1st January 2000. Refer to [Z2] for ZigBee
specification of the time cluster. The metering device will use this clusters
as a client – provided that a suitable Time Server is available on the network
(most likely on the Gateway/concentrator)
If the device has bound TIME cluster, then the device will acquire the value
of Local Time (0x0007) spontaneously.
OccupancySensing-0x0406(client) The attributes that can be received:
Attribute | Type | Description |
---|
0x0000
|
bitmap8 ,
| Occupancy
Bit 0 specifies the sensed occupancy as follows: 1 = occupied, 0 = unoccupied.
This flag bit will affect the Occupancy attribute of HVAC cluster, and the operation mode.
Thermostat User Interface Configuration-0x0204(Server) Attributes supported:
Attribute | Type | Description |
---|
0x0000
| Enum8,
reportable
| TemperatureDisplayMode
0x00 Temperature in , only support
0x0001
|
Enum8,
reportable
| KeypadLockout
0x00 No Lockout
0x01 – 0x05 lockout
Application Endpoint #2–OTA
Cluster | supported | Description |
---|---|---|
0x0000 | server | Basic |
0x0003 | server | Identify |
0x0019
| ****
Client
| OTA Upgrade
Pull-oriented firmware upgrade. Searches the network for mating servers and allows the server to control all stages of the upgrade process, including which image to download, when to download, at what rate and when to install the
downloaded image.
- Ota complies to standard Zigbee protocol.
- Namron AS
- Nedre kalbakkvei 88B 1081 Oslo
- Norway
- post@namron.com
Documents / Resources
|
namron 4512737 Touch Zigbee 16A
Thermostat
[pdf] Instruction Manual
4512737, Touch Zigbee 16A Thermostat, 4512737 Touch Zigbee 16A Thermostat,
Zigbee 16A Thermostat, 16A Thermostat, Thermostat
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>