namron 4512735 Zigbee Smart Plug Instruction Manual
- June 3, 2024
- NAMRON
Table of Contents
namron 4512735 Zigbee Smart Plug
Important: Read All Instructions Prior to Installation
Function introduction
Product Data
Zigbee profile | 0x0104( ZHA) |
---|---|
Device ID | 0x000A( Plug- in Unit) |
Radio Frequency | 2.4GHz |
Input Voltage | AC 200- 240V, 50/60Hz |
Max. Load | Total 16A |
Number of AC Output | 4 |
AC Output Load | Max. 16A/output, total 16A for 4 outputs |
Number of USB Port | 2 |
USB Output Voltage | 5VDC |
USB Output Load | Max. 2.1A/output, total 3.1A for 2 outputs |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 350×68×40( mm) |
- ZigBee smart outlet based on latest ZigBee 3.0 protocol
- Zigbee device with 5 endpoints, With 4 AC outputs and 2 USB ports
- The 4 AC outputs can be controlled individually
- Enables to control ON/OFF of the load, supports max. 16 scenes
- ZigBee device that supports Touchlink commissioning
- Supports find and bind mode to bind a Z igBee remote
- Supports zigbee green power and can bind max. 20 zigbee green power switches
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
Operation
- Plug the s mart outlet into AC power source.
- This ZigBee device is a wireless receiver that communicates with a variety of ZigBee-compatible systems. This receiver receives and is controlled by wireless radio s ignals from the compatible ZigBee system.
- .Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee Network)
- Step1: Remove the device from the previous Zigbee network if it has already been added to, otherwise pairing wil fail. Please refer to the part”Factory Reset Manually”
- Step 2: From your ZigBee Controller or hub interface, choose to add lighting device a nd enter Pairing mode as instructed by the controller.
- Step 3: Short press Program” utton 5 times continuously to set the device to network pairing mode, LED indicator will flash3 times slowly then flash fast.
- Step 4: LED indicators will flash 6 times to indicate successful pairing. LED indicator will maintain the status before entering into network pairing mode if pairing fails.
TouchLink to a Zigbee Remote
Step 1: Short press “Prog” button 4 times (Or re-power on the device 4 times) to start Touchlink commissioning, 180S timeout. Once timeout, repeat the operation.
Note:
- Directly TouchLink ( both not added to a Z igB ee network), e ac h device can link with 1 remote.
- TouchLink after both added to a ZigBee network, each device can link with max. 3 0 remotes .
- To control by both gateway and remote, add remote and device to network first then TouchLink. 4 ) After TouchLink, the device can be controlled by the linked remotes.
Removed from a Zigbee Network through Coordinator or Hub Interface
Factory Reset Manually
Step 1 : Short press the “program” button 5 times continuously, the outlet will be reset to factory default and enter into network pairing mode.
Factory Reset through a Zigbee Remote ( Tou c h R es et)
Note: Make sure the device already added to a network, the remote added to the
same one or not added to any network.
Find and Bind Mode
Note: Make sure both the device and remote are added to the same gateway that
supports find and bind.
Find and Bind Mode
Note: Make sure both the device and remote are added to the same gateway that
supports find and bind.
Delete Learning to a Zigbee Green Power Switch
Setup a Zigbee Network & Add Other Devic es t o the Network ( No Coordinator Required)
Step 1 : Short press “Program” button 4 times to enable the device to setup a zigbee network (LED indicator flashes twice) to discover and add other devices, 180 seconds timeout, repeat the operation.
Step 2 : Set another device or remote or touch panel into network pairing mode
and pair to the network, refer to their manuals.
Step 3: Pair more devices and remotes to the network as you would like, refer
to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the
devices can be controlled by the remotes, refer to their manuals.
Note:
Each added device can link and be controlled by max. 3 0 added remotes
Each added remote can link and control max. 3 0 added devices .
ZigBee Clusters the device supports are as follows
Input Clusters
- 0x0000: Basic • 0x0003: Identify • 0x0004: Groups • 0x0005: Scenes • 0x0006: On/off 0x0b05: Diagnostics
Output Clusters
0x0003: Identify 0x0019: OTA
Namron AS
Nedre kalbakkvei 88B1081 Oslo
Norway
post@namron.com