namron Z-Wave 16A Touch Termostat Instruction Manual

June 3, 2024
NAMRON

Z-Wave 16A Touch Termostat

INSTRUCTION MANUAL
NAMRON TERMOSTAT TOUCH Z- WAVE 16A

INSTRUCTION MANUAL
Namron termostat touch Z-Wave 16A

81mm

Technical data

81mm

28.4mm 21.3mm

Z-Wave frequency Operation voltage Maximum load Power consumption Ambient temperature Temperature range

868.42MHz (EU) 220-240V, 50/60Hz 16A <2W 0°C to 40°C (during operation) 0°C to 40°C

Hysteresis

0.5°C to 2°C (default 0.5°C)

Floor sensor

NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included)

Floor sensors supp orted NTC R25=10K±1%@25°C, B25/50=3950K±1% (factory setting)
NTC R25=12K±1%@25°CB25/50=3950K±1% NTC R25=15K±1%@25°C, B25/50=3950K±1%
NTC R25=50K±1%@25°C, B25/50=3950K±1%
NTC R25=100K±1%@25°C, B25/50=3950K±1%

Control modes

1. Away 2. Auto 3. Manual 4. Drying 5. Off

Control types IP rating Relative humidity Standard
Certificate

Room sensor (factory default) Floo r sensor Room + floor sensor This parameter can also be configured through advance config pa rameter 10
IP21
8% to 80%
EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1 EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019, EN 60730-1:2016+A1:2019, EN 60730-2-19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-1V2.2.3, ETSI EN301 489-3V2.1.1 ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1 RED:2014/53/EU
Z-Wave plus, CE, RED

Installation
a.Installation must be done by a qualified electrician. b.Power supply must be turned off during installation.
(1) Wiring diagram
LN

4512744 SR-ZV9092A

NTC

L LNN

Floor temp sensor
(2) Mounting
a. Remove the display unit and front cover by using a small screwdriver. b. Insert the wires to the correct terminals as presented in the wiring diagram above. Suggested
wire-stripping length is 8-10mm. c. Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is
fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).

Symbol overview

Settings Menu
How to enter settings menu: 1. Under Home Interface, meanwhile the device is at OFF mode , press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu. 2. Short press move up and down button to select a settings item, then short press button F to enter selected item. 3. Settings menu include, Preview menu, Z-Wave settings, Schedule, Monitor settings, Time/Date settings, Other settings.
Time Setting
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:
Short press button to select the item you would like to modify, then short press up and
down buttons to modify value of selected item, then short press button F to save and quit,
short pressing button only quits without saving.

2. Preview interface On Home Interface, user can enter into PREVIEW consumption, date, floor temperature etc.

interface, the interface will display some basic configurations, energy

Control Mode
Short press button on Home Interface to switch operation modes: the icons of Away, Auto, Manual, Drying, Off modes
will be displayed alternatively for 3 seconds and last displayed mode will be selected, or just short press F button to select
a desired mode when the modes’ icon displayed alternatively. Press and hold button on Home interface for over 3
seconds to select Away mode directly, then Press and hold button for 3 seconds to quit Away mode.

1.Away Mode: the device will control the heating system according to the set temperature within the set period. User can set time to leave home and time to go home according to the requirements of themselves, and set how the device will control the temperature during this period. 1.1. If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode Temperature Schedule before the end time. 1.2. If away mode has already been activated, the values of end time for away mode are set as 0, the device will always execute current set temperature with no time limitation. The device will consider the mode as anti- freeze mode, the recommended temperature setting is 4-10°C.

2. Auto Mode: the device will control the heating system according to the configured time schedule or Z-Wave protocol Energy_Save_Heating Setpoint. 2.1. When configuration parameter 8 value set as 1, the device will control the temperature of energy save mode accord ing to the temperature set by Command Class Energy_Save_Heating Setpoint or set by using the move up and down buttons, following mentioned schedule will be invalid. 2.2. When configuration parameter 8 value set as 0, the temperature set by Command Class Energy_Save_Heating Setpoint and set by using the move up and move down buttons will both be invalid, Energy Save Mode will control temperature according to following user schedule. For instance, if user would like to keep room temperature at 18C during 18:00-23:00 on every Monday, and keep room temperature at 20C after 22:30 on every Monday, then user can set schedule by himself.

Schedule setting method 1: user can enters into as follows:

schedule on Z-Wave Set Interface, the schedule interface is

Short press button to select “Auto Schedule”, then short press button F Schedule weekly setting interface.

Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly:
On Auto Mode Schedule weekly setting interface, use buttons and F to enter into schedule setting of a certain week as
follows:
On Auto Day Schedule interface, short press button to select the time or temperature that you would like to modify, then short press move up and down buttons to modify value, then short
press button F to save and quit, short pressing button only quits without saving.
For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error remind “Time setting error!!!”. The default time schedules are as follows:

Monday-Friday

7:30,24C-12:00,20C 18:00,16C-22:30,18C

7:30,24C-12:00,20C Saturday-Sunday
18:00,18C-22:30,18C

3. Manual Mode: the device will control the heating system according to current set temperature. The temperature can be set by move up and move down button on the Home interface, or configured by Z-Wave gateway.
4.Drying Mode: The device will judge the set temperature for heating within a short period of time. I.e.: in order to dry the water in the bathroom in a short time, the device could be set to quickly heat to dry the floor. Enter the configuration interface as follow: Duration: set how long the dry mode should lasts After Mode: set the mode after the drying mode ends Remain: shows the remaining time of the drying mode

For configuration method and modification, please refer to Automatic Mode (Energy Save Mode) Schedule:

5.Off Mode: this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions, otherwise the device will not work, meanwhile the standby interface will only show room temperature.

Monitor Set

The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows: Short press button to select the item would like to modify, then short press move up and down buttons to modify value of selected
item, then short press F button to save and quit, short pressing
button only quits without saving.

Over-current Alarm
Max floor temp
Hysterersis
Key Vibration Set
Display Brightness Set
Display Auto Off

If current is over the set value, the relay will be forced to off by the device, and the state will be reported to the gateway. The over current alarm function can be disabled, which can be set directly through the device, or can be configured through Advance Config parameter 2 by setting the value as 0 to disable the function, please refer to the part “Advance Config”. Note: When over current alarm is triggered, the beeper will beep, to cancel the alarm, just press and hold button for over 3 seconds or reset power of the device. After cancel manually, the relay will show heating forbidden icon within 120 seconds, but other operations are allowed.
This function is similar to the function of “Internal Over Heat Protection” described in chapter 9. When the control type is configured as “Room+Floor sensor”, this function will be valid: The alarm will be triggered when the floor sensor temperature > Max floor temp, the relay will be forced to off by the device, and the state will be reported to the gateway. The following indication figure will prompt on the display. After the floor sensor temperature < (Max floor temp – Hysteresis), the alarm will be cancelled automatically and the device will restore to previous operation mode. To cancel the alarm manually, just press and hold button for over 3 seconds, but the relay will show heating forbidden icon within 120 seconds and the alarm will not be triggered again, after 120 seconds expire, the device will restore to previous operation mode and continue to detect alarm temperature. This function can be disabled, which can be configured directly through the device, or can be configured through Advance Config parameter 6 by setting the value as 0 to disable the function, please refer to the part “Advance Config”.
To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature, which will cause that the controller may keep switching on/off the relay. Here hysterersis enables the controller to control the relay only when the sensor temperature is lower than the set temperature minus the hysteresis value , this value can be set. For instance, when hysterersis is set as 0.5 degree, then only when current sensor temperature < (the set temperature – 0.5 degree), will the controller heat. This value can also be configured through Advance Config parameter 7, please refer to the part “Advance Config”.
Set the level of vibration sensor under the buttons or buzzer level. OFF: vibration or buzzer off Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level. The level can also be configured through Advance Config parameter 03.
The OLED display brightness when operate the device. High Level, Mid Level, Low Level. This parameter can also be configured through Advance Config parameter [22].
Once the device goes to standby interface, if there is no operation within 30s, the display will go off automatically.

Display Temperature Set
Other Set
Temperature Compensation
Re-power Status
Internal Over Heat Protection
Child Lock
Display Auto Off Function
Activation

This parameter defines which sensor temperature will be displayed on Home page. Floor Temp: floor temperature (external sensor) . Home Temp: indoor air temperature. This parameter can also be configured through Advance Config parameter [23].
Select OTHER SET on Home Interface to enter into OTHER SET interface as follow: Short press button to select the item you would like to modify, then short press move up and down buttons to modify value of
selected item, then short press button F to save and quit, short
pressing button only quits without saving.
The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do temp compensation to room sensor and floor sensor. Compensation range is -5 ~ +5°C, stepping is 0.5°C. This parameter can a lso be configured through Advance Config parameter [11] and [12] .
Device state after reset power of the device. If set as “last status”, device will go to the status before power failure after power on again. If set as “default”, device will go to default mode after power on again. This parameter can also be configured through Advance Config parameter [4].
To ensure the safety of the device, if the internal temperature of the device (not displayed on the interface) is over a certain value during heating process, the device will execute a short tempo rary action to turn off the relay, and the icon will appea r on the interface, after the tempera ture decreases to a certain value, the device will recover to work.
F Press and hold and buttons for over 10S,then the child lock
can be activated or cancelled. When child lock is activated, then icon will appear on the display.

F On the Home Interface, press and hold both and

buttons for

over 10S, during the process, the icon will flash slowly, the Display

Auto OFF function can be enabled or disabled, when the function is

enabled, the icon will be displayed, otherwise the icon will not be

displayed.

This parameter can also be configured through Advance Config

parameter [27] .

Z-Wave Set Introduction

1 .Z-Wave Network Management

Select

ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow:

Adding to a Z -Wave Network ( Inclusion) Method 1: Select “Add”, then short press button , the device will send out inclusion request, “Status” will show “Inclusion…”. If there is no response from a gateway within 30 seconds, or inclusion failed, “Status” will show “Fail”. If included successfully, “Status” will show “Inclusion OK” and device ID. Method 2: Operate the gateway into inclusion mode, make sure the device is already removed from previous network, reset power of the device, the device will be included to the gateway automatically.

Smart Start If the user’s gateway also supports smartstart, add the device by scanning the QR code, Smartstart allows users to quickly add devices to the gateway by scanning the device’s QR code. After scanning to add the device, reset power of the device or waiting for a while, the device will be added to the gateway automatically. Please find the QR code on the casing of the device.
Removing from a Z-Wave Network (Exclusion)
Select “Remove”, then short press button F , the device will send out exclusion request, “Status” will show “Exclusion… If “.
there is no response from a gateway within 30 seconds, or exclusion failed, “Status” will show “Fail”. If excluded successfull,y “Status” will show “Exclusion OK” and device ID will be showed as 0.
Factory Reset (Reset) Factory resetting will reset all Advance Config parameters to default value, and the device will be removed from the Z-Wave network.
Select “Reset”, then short press button F, the device will start reset, “Status” will show “Reset…”. If there is no response
from a gateway within 6 seconds, or exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”. Note 1: if the device is excluded or reset successfully, the Auto Mode Schedule will be reset to default value. Note 2: the sent frame of inclusion and exclusion is INFO frame.
2.Basic set command class Set the device operation mode as Comfort Mode (Manual Mode) by sending command class basic set = 0XFF. Set the device operation mode as OFF mode by sending command class basic set = 0x00

Z-Wave Technical Specifications
1.Supported Notification Report and Sensor Type

Notifcation Type

Triggering Event

Description

POWER_MANAGEMENT

POWER_MANAGEMENT_OVERCURRENT_DETECTED Over Current Alarm

Heat Alarm

Overheat detected

Over Heat Alarm

SENSOR MULTILEVEL Type support Air temperature
2. Technical Specifications Item SDK
Explorer Frame Support

Scale Celsius (¥)
Definition 6.82.00 Yes

Device Type Generic Device Class Specific Device Class
Role Type Routing

Thermostat(HVAC) GENERIC_TYPE_THERMOSTAT SPECIFIC_TYPE_THERMOSTAT_HEATING
Always On Slave (AOS)) Yes

ermostat Related Specifications

Command

Support

ThermostatMode ThermostatSetPoint

ThermostatMode_OFF(off) ThermostatMode_HEAT(UI displays Manual) ThermostatMode_DRY ThermostatMode_EnergyHeat(UI displays Auto) ThermostatMode_Away(UI displays Away) ThermostatSetPointType_Heating(set manual temperature) ThermostatSetPointType_Energy_Save_Heating(set auto temperature) ThermostatSetPointType_DRY ThermostatSetPointType_Away_Heating(set away temperature)

3. Supported Command Class Root Device
Suppourt Command class

Support S2/s0

COMMAND_CLASS_ZWAVEPLUS_INFO

V2

COMMAND_CLASS_SECURITY

V1

COMMAND_CLASS_SECURITY_2

V1

COMMAND_CLASS_TRANSPORT_SERVICE

V2

COMMAND_CLASS_SUPERVISION

V1

COMMAND_CLASS_THERMOSTAT_MODE

V3

YES

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE

V1

YES

COMMAND_CLASS_THERMOSTAT_SETPOINT

V2

YES

COMMAND_CLASS_ASSOCIATION

V2

YES

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION

V3

YES

COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_VERSION

V1

YES

V3

YES

COMMAND_CLASS_MANUFACTURER_SPECIFIC

V2

YES

COMMAND_CLASS_DEVICE_RESET_LOCALLY

V1

YES

COMMAND_CLASS_POWERLEVEL

V1

YES

COMMAND_CLASS_TIME_PARAMETERS

V1

YES

COMMAND_CLASS_CONFIGURATION

V1

YES

COMMAND_CLASS_NOTIFICATION

V8

YES

COMMAND_CLASS_METER

V3

YES

COMMAND_CLASS_MULTI_CHANNEL

V4

YES

COMMAND_CLASS_FIRMWARE_UPDATE_MD

V4

YES

Controlled command class COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT

Support S2/s0

V3

YES

V2

YES

Note: the EndPoint01 mirrors equivalent effect root endpoint. EndPoint1 command list:
Support command class COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION OMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_THERMOSTAT_SETPOINT
COMMAND_CLASS_METER
EndPoint2 (floor temperature sensor) command list: Support command class
COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO

Support S2/s0 V2

V1

V1

V1

V5

YES

V2

YES

V3

YES

V1

YES

V3

YES

V1

YES

V2

YES

V3

YES

Support S2/S0

V2

V1

V1

V1

V5

YES

V2

YES

V3

YES

V1

YES

5.Association Root device

Group ID 1

NAME Lifeline

Profile
AGI_LIFE_LINE c0x0001

Max nodes 5

Description
1.Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices of this group when factory reset the device. 2.Send Command Class THERMOSTAT_SETPOINT_REPORT, THERMOSTAT_MODE_REPORT, THERMOSTAT_OPERATING_STATE_REPORT to associated devices of this group When operation mode and temperature change. 3.Send Command Class NOTIFICATION_REPORT to associated devices of this group when over current, over heat detected 4.Send Command Class METER_REPORT to associated devices of this group to report metering parameters.

AGICONTROL

2

Heat Set

KEY01

5

(0x2001)

Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other temperature control devices when operation changes

EndPoint01 :

Group ID NAME

Profile Max nodes

1

Lifeline

AGI_LIFE_LINE c0x0001

0

Note: the EndPoint01 has equivalent effect of root function. EndPoint02

Group ID NAME

Profile Max nodes

1

Lifeline

AGI_LIFE_LINE c0x0001

0

Description Lifeline(0x0001)
Description Lifeline(0x0001)

6.Advance Config Parameters

Parameter Size Description

Default Parent Value Menu

0x02(2)

Over current detection max. value, unit is A. When detected current is

over this

1

value, the device will turn off the relay and send NOTIFICATION CC.

0, disable over current detection

5-16, over current detection max. value

16 Monitor Set

0x03(03) 0x04(4) 0x06(6)

Vibration level and buzzer level triggered by pressing buttons 0, disable

vibration and buzzer

1

1, Low Level

2, High Level

Whether to recover to settings before power failure or power reset

1

0, use default settings

1, recover to settings before power failure or power reset

Floor temperature detection max. value, unit is ¥ , when floor temperature

sensor is higher than this value, the device will turn off the relay and send

1

NOTIFICATION CC.

0, disable this function

1-35, the high temperature value

1

Other Set

1

Other Set

27 Monitor Set

0x07(7) 0x08(8)

1

Temperature control hysteresis value setting, setting range 0.5¥-5¥. value range is 5-50, unit is 0.1¥

Auto mode (Energy save mode) temperature schedule

1

0, use schedule set by user

1, use Energy _Save_Heating temperature set by THERMOSTAT_SETPOINT_SET

5

Monitor Set

0

None

0x09(9)

Select floor temperature sensor type

1, NTC/10K B(25/50°C)=3950

1

2, NTC/15K B(25/50°C)=3950

3, NTC/50K B(25/50°C)=3950

4, NTC/100K B(25/50°C)=3950

5, NTC/12K B(25/50°C)=3950

1

Other Set

0x0A(10)

Temperature control reference selection

1, room sensor

1

2, floor sensor

3, room+floor sensor

1

Other Set

0x0B(11) 0x0C(12) 0x0D(13)
0x0E(14)

1

ROOM SENSOR temperature compensation setting -10~10, unit is 0.5 ¥

FLOOR S ENSOR temperature compensation setting

1

-10~10, unit is 0.5 ¥

1

Set how long the drying mode lasts 5~100, unit is minute

Set the mode a fter the drying mode ends

0x00 = OFF

1

0x01 = Manual mode (comfort mode)

0x02 = Auto mode (energy save mode)

0x03 = Away mode

0

Other Set

0

Other Set

30

Dry Mode Schedule

2

Dry Mode Schedule

0x10(16)

When to report temperature relative change threshold value actively, unit

1

is 0.1¥ 0, d isab l e t o r ep or t

2- 10, rep or t when t he threshold v alue i s 2- 10

2

None

0x11(17) 0x12(18) 0x13(19) 0x14(20) 0x15(21) 0x16(22)
0x17(23) 0x18(24) 0x1B(27)

Time interval value for periodic report of temperature, humidity, unit is S

1

0, disable to report

30~28800, report when time interval value is 30~28800

When to report power change absolute threshold, unit is W

1

0, disable to report

1~100, report when absolute threshold is 1~100

When to report current change absolute threshold, unit is 0.1A

1

0, disable to report

1~10, report when absolute threshold is 1~10

When to report voltage change absolute threshold, unit is 1 V

1

0, disable to report

1~10, report when absolute threshold is 1~10

4

Time interval value for periodic active report of Meter 60-2678400 (31 days) , unit is S

The OLED display brightness when operate the device.

0, low level

1

1, mid level

2, high level

This parameter defines which sensor temperature will be displayed on

1

Home page. 0x00: indoor a ir temperature

0x01: external temperature (floor temperature)

The time zone that the time parameters command adopts is UTC, the time

1

zone need to be set:

+12 ~ -12

Enable or disable Display Auto Off function when the interface is standby

1

interface. 0, disbaled

1, enabled

300 (5mins)

None

5

None

10

None

2
600 (10mins)

None None

1

Other Set

0

Other Set

0

Other Set

0

Namron AS Nedre kalbakkvei 88B
1081 Oslo Norway
post@namron.com

NAMRON Z-WAVE RELÉ 16A

Important: Read All Instructions Prior to Installation Function introduction
S witch input

Action button

NC S

09.ZV09SAPSB.04739
LE D indica tor, indica tes when progra m the switch ( inclusion,
exclusion, fa ctory reset)

1 CH load output
Pro du c t Data Z – Wa ve F requency Input Volta ge Output Volta ge Output Current
Opera ting tempera ture R ela tive humidity Dimensions

AC 100-240V power input
868.42 MHZ ( E U) AC100-240V AC100-240V 16A ma x. 0 to 40°C 8% to 80%
45.5x45x20.3mm

Load Symbol

Compatible Load T ypes

Load Type

Maximum Load

LED lamps with transformers

1220W @ 2 30V 580W @ 110V

LED drivers
Inca ndescent lighting, HV H a logen la mps

1220W @ 2 30V 580W @ 110V
3680W @ 2 30V 1760W @ 110V

Remarks
Due to va riety of LE D la mp designs, ma ximum number of LE D la mps is further dependent on power fa ctor result when connected to switch.
Ma ximum permitted number of drivers is 1220W divided by driver na mepla te power ra ting.
Max. continuous load 10A

Low volta ge ha logen lighting with electronic tra nsformers
E lectrica l a pplia nces such a s television, refrigera tor, wa ter hea ting etc.

1220W @ 2 30V 580W @ 110V
3680W @ 2 30V 1760W @ 110V

Max. continuous load 10A

S afety & Warn in gs · DO NOT insta ll with power a pplied to device. · DO NOT expose the device to moisture.
Quick Start How to insta ll: · S tep 1: power on the Z – Wa ve in- wa ll switch. · S tep 2: a ctiva te inclusion mode on your Z – Wa ve controller. · S tep 3: a ctiva te inclusion mode of the switch by triple press the a ction button on the switch. T he switch will be included to Z – Wa ve network.
Pro du c t Des c riptio n T he in- wa ll switch is a Z – Wa ve device tha t is used to switch ON/OF F the connected light or electrica l a pplia nces a nd ca n be controlled by other Z – Wa ve devices. T he In- wa ll switch ca n be included a nd opera ted in a ny Z – Wa ve network with other Z – Wa ve certified devices from other ma nufa cturers a nd/or other a pplica tions. All non- ba ttery opera ted nodes within the network will a ct as repea ters rega rdless of vendor to increa se relia bility of the network.
T his device supports the S ma rtS ta rt inclusion. S ma rtS ta rt ena bled products ca n be a dded into a Z – Wa ve network by sca nning the Z – Wa ve QR C ode present on the product with a c ontroller providing S ma rtS ta rt inclusion. No further a ction is required a nd the S ma rtS ta rt product will be a dded a utoma tica lly within a p eriod a fter the QR c ode being sca nned or reset power of the device. P lea se find the QR c ode on the device ca sing.
T he encryption mode tha t the switch supports is S 2 Una uthentica ted. When the switch is being included into a Z – Wa ve network, you ca n use your prima ry controller/ga tewa y to ena ble encryption mode or disa ble encryption. ( T he prima ry controller/ga tewa y sha ll support encryption mode configura tion) . T he switch supports OTA a nd ca n upda te firmwa re wirelessly. In a ddition, the switch is equipped with P ower Metering a nd over current protection. Operation
Installation G uide P lea se rea d ca refully the enclosed user ma nua l before insta lla tion of the in- wa ll switch, in order to ensure a n error- free functioning.
ATTE NTION: P rior to the a ssembly of the product, the volta ge network ha s to be switched OF F a nd ensured a ga inst re- switching.
Inclusion (adding to a Z-Wave network) 1. S et prima ry controller/ga tewa y into inclusion mode ( P lea se refer to your prima ry controllers ma nua l on how to turn your controller into inclusion) .
2. P ower on the in- wa ll switch a nd set it into inclusion mode. T here a re two methods to set the in- wa ll switch into inclusion mode: 1) Triple press the a ction button on the switch, LE D indica tor will fla sh ra pidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the ga tewa y, the device will quit inclusion mode a fter 30 seconds. 2) When the va lue of pa ra meter 5 is configured a s 1, triple press the externa l switch ra pidly within 1.5 seconds, LE D indica tor will fla sh ra pidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the ga tewa y, the device will quit inclusion mode a fter 30 seconds.
T he LE D indica tor will sta y solid on for 3 seconds if the device is a dded to the network successfully. T he indica tor will turn off if inclusion fa ils.
Exclusion (removing from a Z-Wave network) T here a re two exclusion methods: Method 1: E xclusion from the prima ry controller/ga tewa y a s follows: 1. S et the prima ry controller/ga tewa y into exclusion mode ( P lea se refer to your prima ry controllers ma nua l on how to set your controller into exclusion) .
2. P ower on the in- wa ll switch a nd set it into exclusion mode. T here a re two methods to set the in- wa ll switch into exclusion mode: 1) Triple press the a ction button on the switch, LE D indica tor will fla sh ra pidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the ga tewa y, the device will quit exclusion mode a fter 30 seconds. 2) When the va lue of pa ra meter 5 is configured a s 1, triple press the externa l switch ra pidly within 1.5 seconds, LE D indica tor will fla sh ra pidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the ga tewa y, the device will quit exclusion mode a fter 30 seconds.

T he LE D indica tor will sta y solid on for 3 seconds if the device is removed from the network successfully. T he indica tor will turn off if exclusion fa ils.
Method 2: F a ctory reset the switch will force the switch to be excluded from a network. ( plea se refer to the pa rt “F a ctory R eset” of this ma nua l)
Note: F a ctory reset is not recommended for exclusion, plea se use this procedure only if the prima ry controller/ga tewa y is missing or otherwise inopera ble.
F ac to ry R es et P ress a nd hold down the a ction button for over 10 seconds, LE D indica tor fla shes slowly, the switch will resta rt a nd reset to fa ctory defa ults.
S c en e C o n tro l Users ca n configure scenes using comma nd cla ss S C E NE AC T UATOR C ONF S E T, a nd a ctiva te the scenes using comma nd cla ss S C E NE AC T IVAT ION_ S E T.
As s o c iation Z – Wa ve devices control other Z – Wa ve devices. T he rela tionship between one device controlling a nother device is ca lled a ssocia tion. In order to control a d ifferent device, the controlling device needs to ma inta in a l ist of devices tha t will receive controlling comma nds. T hese lists a re ca lled a ssocia tion groups a nd they a re a lwa ys rela ted to certa in events ( e.g. button pressed) . In ca se the event ha ppens a ll devices stored in the respective a ssocia tion group will receive a c ommon wireless comma nd.

As s oc iatio n G rou ps :

Associa tion Groups

Group Na me

Group 1

Lifeline

Ma x Nodes
5

Description
1. When press a nd hold down “R eset” button for 10S to reset the device, send ” Device R eset Loca lly Notifica tion” to a ssocia ted devices of this group to report fa ctory reset informa tion.
2. When over loa d detected, send ” NOT IF IC AT ION_ R E P ORT ” to a ssocia ted devices of this group.
3. R eport energy meter a ctively.
4. S end ba sic report automa tica lly.

S et an d u n s et as s oc iatio n s : ( Note: All a ssocia tion informa tion will be clea red a utoma tica lly once the switch is excluded from a network.) S et associa tion by opera ting prima ry controller/ga tewa y to send pa ckets to the switch: T he prima ry controller/ga tewa y sends pa ckets to the switch using “C omma nd C la ss AS S OC IAT ION”
No de I n formatio n F rame T he Node Informa tion F ra me is the business ca rd of a Z – Wa ve device. It conta ins informa tion a bout the device type a nd the technica l ca pa bilities. T he inclusion a nd exclusion of the device is confirmed by sending out a Node Informa tion F ra me. Beside this it ma y be needed for certa in network opera tions to send out a Node Informa tion F ra me. How to send out Node Informa tion F ra me: When the switch is set to inclusion/exclusion mode a ga in, it will send out Node Informa tion F ra me, there a re 2 kinds of opera tion a s follows: 1. Triple press the a ction button, the dimmer will be set to inclusion/exclusion mode, then send out Node Informa tion F ra me. 2. When the switch is under inclusion mode, there a re two kinds of opera tion: 1) Triple press inclusion/exclusion button, the switch will be set to inclusion mode a ga in, a nd send out Node Informa tion F ra me. 2) P ower off and power on the switch, it will be set to inclusion mode a utoma tica lly, a nd send out Node Informa tion F ra me.

Tec h n ic al D ata
Wireless R a nge SDK
E xplorer F ra me S upport Device Ty pe
Generic Device Class S pecific Device C la ss
R ole Ty pe R outing

up to 100 m outside, on a vera ge up to 40 m inside buildings 7.13.6.0 Yes
On/Off Power S witch G E NE R IC T Y P E S WIT C H BINARY S P E C IF IC T Y P E P OWE R S WIT C H_ BINARY
Alwa ys On S la ve ( AOS ) Yes

S u ppo rted C omman d C las s Node I nfo

S ec u rity C o mman d S u ppo rted R epo rt

C OMMAND C LAS S Z WAV E P LUS _ INF O

V 2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V 2

C OMMAND C LAS S T R ANS P ORT _ S E RV IC E V 2

C OMMAND C LAS S V E R S ION

V3

C OMMAND C LAS S S E C UR IT Y

V1

C OMMAND C LAS S S WIT C H_ BINARY

V2

C OMMAND C LAS S S E C UR IT Y 2 C OMMAND C LAS S _ S UP E RV IS ION

V 1 C OMMAND C LAS S S C E NE AC T IVAT ION V 1 V 1 OMMAND C LAS S S C E NE AC T UATOR _ C ONF V 1

C OMMAND C LAS S ME T E R

V5

C OMMAND C LAS S NOT IF IC AT ION

V8

C OMMAND C LAS S C ONF IG UR AT ION

V1

C OMMAND C LAS S AS S OC IAT ION G R P INF O V 1

C OMMAND C LAS S AS S OC IAT ION

V2

C OMMAND C LAS S F IR MWAR E UP DAT E MD V 4

C OMMAND C LAS S P OWE R LE V E L

V1

C OMMAND C LAS S DE V IC E R E S E T LOC ALLY V 1

C OMMAND C LAS S INDIC ATOR

V3

Notific atio n R epo rt

No tific atio n T ype NOT IF IC AT ION T Y P E P OWE R MANA
G E ME NT ( 08) NOT IF IC AT ION
T Y P E P OWE R MANA
G E ME NT ( 08)

Tr iggerrin g E ven t P OWE R MANAG E ME NT OV E R C UR R E NT
DETECTED(06) P OWE R
MANAG E ME NT OV E R LOADE D N
T_DETECTED(08)

Over C u rren t Alarm: When connecting to resistive loa d, over current protection va lue is 16A.

Note: When over current or overloa d protection is ena bled ( va lue of configura tion pa ra meter 4 not configured a s 0) , if the device detects tha t the loa d current is over 16A or power is over 3700W, the rela y will be forced to off, unless reset power of the device, otherwise the device will a lwa ys be a t ala rm sta tus, a nd report ala rm every 60 seconds.

C on figu ratio n C o mman d C las s

P a ra meter

Size

Description Info: S a ving loa d sta te before power fa ilure

0x02(2)

0 shutoff loa d 1
1 turn on loa d

0x03(3)

2 sa ve loa d sta te before power fa ilure

Info: E na ble/disa ble to send the ba sic report to the Lifeline when the loa d sta te cha nged

1

0 Disa ble to send Ba sic report

0x04(4)

1 E na ble to send Ba sic report

E na ble/disa ble over current or over loa d protection, report a la rm when the loa d is over 16A if ena bled

1

0: disable

1: enable E xterna l switch type

0x05(5)

1

0: push button switch

1: norma l on/off switch
Added to a nd removed from a network through externa l switch ( when ena bles this function, triple press the externa l switch to be a dded to or removed from a network)

0x07(7)

0 – disable

1

1 – enable

Note: if this function is ena bled, when triple press the switch ra pidly, the device will be set to inclusion or exclusion mode, then device sta tus will not be reported ( ba sic report) d uring this process.
P ower cha nge a bsolute threshold report, report when the power cha nge va lue is over the threshold, unit is W

0x0A(10)

1

0: disa ble a bsolute threshold report function

1- 255: va lue of the power cha nge a bsolute threshold, if power cha nge va lue is over the threshold va lue, report the power cha nge va lue using ME T E R _ R E P ORT

C urrent cha nge a bsolute threshold, unit is 0.1A

0x0B( 11)

0: disa ble a bsolute threshold function 1
1- 255: va lue of the current cha nge a bsolute threshold, if current cha nge va lue is over the threshold va lue, report the current cha nge va lue using ME T E R _ R E P ORT
Vo lta ge cha nge a bsolute threshold, unit is 1V

0x0C(12) 0x0d(13)

0: disa ble a bsolute threshold function 1
1- 255: va lue of the volta ge cha nge a bsolute threshold, if volta ge cha nge va lue is over the threshold va lue, report the volta ge cha nge va lue using ME T E R _ R E P ORT

Time cycle to report the va lues of energy

consumption, volta ge, current and loa d power

4

a ctively

60- 2678400 ( 31 da ys) , va lue of the time cycle, unit is S .

Defa ult Va lue 2 1 1 0
1
5 1 2 1800( 30mins)

Wirin g Diagram Notes f o r th e d iagrams : L – termina l for live lea d N – termina l for neutra l lea d L1 – o utput termina ls of the device ( controlling connected light source) S – termina l for externa l switch NC – N o C onnection

  1. With Normal On/Off Switch
    NC S

L N

  1. With Single Push Button Switch

PUSH

NC S

L N

  1. With Multiple Push Switches for Multiple Control Points

PUSH

PUSH

NC S

  1. Connect With Socket

PUSH

NC S

Product Dimension
45 mm L N
L N GND

45.5 mm 20.3 mm

Namron AS Nedre kalbakkvei 88B