Z-Wave 16A Touch Termostat
INSTRUCTION MANUAL
NAMRON TERMOSTAT TOUCH Z- WAVE 16A
INSTRUCTION MANUAL
Namron termostat touch Z-Wave 16A
81mm
Technical data
81mm
28.4mm 21.3mm
Z-Wave frequency Operation voltage Maximum load Power consumption Ambient temperature Temperature range
868.42MHz (EU) 220-240V, 50/60Hz 16A <2W 0°C to 40°C (during operation) 0°C to 40°C
Hysteresis
0.5°C to 2°C (default 0.5°C)
Floor sensor
NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included)
Floor sensors supp orted NTC R25=10K±1%@25°C, B25/50=3950K±1% (factory
setting)
NTC R25=12K±1%@25°CB25/50=3950K±1% NTC R25=15K±1%@25°C, B25/50=3950K±1%
NTC R25=50K±1%@25°C, B25/50=3950K±1%
NTC R25=100K±1%@25°C, B25/50=3950K±1%
Control modes
1. Away 2. Auto 3. Manual 4. Drying 5. Off
Control types IP rating Relative humidity Standard
Certificate
Room sensor (factory default) Floo r sensor Room + floor sensor This parameter
can also be configured through advance config pa rameter 10
IP21
8% to 80%
EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1 EN IEC 61000-3-2:2019, EN
61000-3-3:2013+A1:2019, EN 60730-1:2016+A1:2019, EN
60730-2-19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-1V2.2.3, ETSI
EN301 489-3V2.1.1 ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1
RED:2014/53/EU
Z-Wave plus, CE, RED
Installation
a.Installation must be done by a qualified electrician. b.Power supply must be
turned off during installation.
(1) Wiring diagram
LN
4512744 SR-ZV9092A
NTC
L LNN
Floor temp sensor
(2) Mounting
a. Remove the display unit and front cover by using a small screwdriver. b.
Insert the wires to the correct terminals as presented in the wiring diagram
above. Suggested
wire-stripping length is 8-10mm. c. Fix the thermostat into the connection box
by tightening the screws. Make sure that the thermostat is
fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).
Symbol overview
Settings Menu
How to enter settings menu: 1. Under Home Interface, meanwhile the device is
at OFF mode , press and hold up and down buttons at the same time for over 5
seconds to enter Settings Menu. 2. Short press move up and down button to
select a settings item, then short press button F to enter selected item. 3.
Settings menu include, Preview menu, Z-Wave settings, Schedule, Monitor
settings, Time/Date settings, Other settings.
Time Setting
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as
follow:
Short press button to select the item you would like to modify, then short
press up and
down buttons to modify value of selected item, then short press button F to
save and quit,
short pressing button only quits without saving.
2. Preview interface On Home Interface, user can enter into PREVIEW consumption, date, floor temperature etc.
interface, the interface will display some basic configurations, energy
Control Mode
Short press button on Home Interface to switch operation modes: the icons of
Away, Auto, Manual, Drying, Off modes
will be displayed alternatively for 3 seconds and last displayed mode will be
selected, or just short press F button to select
a desired mode when the modes’ icon displayed alternatively. Press and hold
button on Home interface for over 3
seconds to select Away mode directly, then Press and hold button for 3 seconds
to quit Away mode.
1.Away Mode: the device will control the heating system according to the set temperature within the set period. User can set time to leave home and time to go home according to the requirements of themselves, and set how the device will control the temperature during this period. 1.1. If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode Temperature Schedule before the end time. 1.2. If away mode has already been activated, the values of end time for away mode are set as 0, the device will always execute current set temperature with no time limitation. The device will consider the mode as anti- freeze mode, the recommended temperature setting is 4-10°C.
2. Auto Mode: the device will control the heating system according to the configured time schedule or Z-Wave protocol Energy_Save_Heating Setpoint. 2.1. When configuration parameter 8 value set as 1, the device will control the temperature of energy save mode accord ing to the temperature set by Command Class Energy_Save_Heating Setpoint or set by using the move up and down buttons, following mentioned schedule will be invalid. 2.2. When configuration parameter 8 value set as 0, the temperature set by Command Class Energy_Save_Heating Setpoint and set by using the move up and move down buttons will both be invalid, Energy Save Mode will control temperature according to following user schedule. For instance, if user would like to keep room temperature at 18C during 18:00-23:00 on every Monday, and keep room temperature at 20C after 22:30 on every Monday, then user can set schedule by himself.
Schedule setting method 1: user can enters into as follows:
schedule on Z-Wave Set Interface, the schedule interface is
Short press button to select “Auto Schedule”, then short press button F Schedule weekly setting interface.
Schedule setting method 2: on Home Interface, meanwhile the device is under
Auto Mode , short press button to enter into Auto Mode Schedule weekly setting
interface quickly:
On Auto Mode Schedule weekly setting interface, use buttons and F to enter
into schedule setting of a certain week as
follows:
On Auto Day Schedule interface, short press button to select the time or
temperature that you would like to modify, then short press move up and down
buttons to modify value, then short
press button F to save and quit, short pressing button only quits without
saving.
For each schedule, the latter time should be later than the former time,
otherwise saving will fail with the error remind “Time setting error!!!”. The
default time schedules are as follows:
Monday-Friday
7:30,24C-12:00,20C 18:00,16C-22:30,18C
7:30,24C-12:00,20C Saturday-Sunday
18:00,18C-22:30,18C
3. Manual Mode: the device will control the heating system according to
current set temperature. The temperature can be set by move up and move down
button on the Home interface, or configured by Z-Wave gateway.
4.Drying Mode: The device will judge the set temperature for heating within a
short period of time. I.e.: in order to dry the water in the bathroom in a
short time, the device could be set to quickly heat to dry the floor. Enter
the configuration interface as follow: Duration: set how long the dry mode
should lasts After Mode: set the mode after the drying mode ends Remain: shows
the remaining time of the drying mode
For configuration method and modification, please refer to Automatic Mode (Energy Save Mode) Schedule:
5.Off Mode: this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions, otherwise the device will not work, meanwhile the standby interface will only show room temperature.
Monitor Set
The function of monitor set is real time monitor of over current, over heat
and freezing. On Home Interface, short press MONITOR SET to enter into monitor
set interface a s follows: Short press button to select the item would like to
modify, then short press move up and down buttons to modify value of selected
item, then short press F button to save and quit, short pressing
button only quits without saving.
Over-current Alarm
Max floor temp
Hysterersis
Key Vibration Set
Display Brightness Set
Display Auto Off
If current is over the set value, the relay will be forced to off by the
device, and the state will be reported to the gateway. The over current alarm
function can be disabled, which can be set directly through the device, or can
be configured through Advance Config parameter 2 by setting the value as 0 to
disable the function, please refer to the part “Advance Config”. Note: When
over current alarm is triggered, the beeper will beep, to cancel the alarm,
just press and hold button for over 3 seconds or reset power of the device.
After cancel manually, the relay will show heating forbidden icon within 120
seconds, but other operations are allowed.
This function is similar to the function of “Internal Over Heat Protection”
described in chapter 9. When the control type is configured as “Room+Floor
sensor”, this function will be valid: The alarm will be triggered when the
floor sensor temperature > Max floor temp, the relay will be forced to off by
the device, and the state will be reported to the gateway. The following
indication figure will prompt on the display. After the floor sensor
temperature < (Max floor temp – Hysteresis), the alarm will be cancelled
automatically and the device will restore to previous operation mode. To
cancel the alarm manually, just press and hold button for over 3 seconds, but
the relay will show heating forbidden icon within 120 seconds and the alarm
will not be triggered again, after 120 seconds expire, the device will restore
to previous operation mode and continue to detect alarm temperature. This
function can be disabled, which can be configured directly through the device,
or can be configured through Advance Config parameter 6 by setting the value
as 0 to disable the function, please refer to the part “Advance Config”.
To prevent the undulation of sensor temperature when the sensor temperature is
approaching the set temperature, which will cause that the controller may keep
switching on/off the relay. Here hysterersis enables the controller to control
the relay only when the sensor temperature is lower than the set temperature
minus the hysteresis value , this value can be set. For instance, when
hysterersis is set as 0.5 degree, then only when current sensor temperature <
(the set temperature – 0.5 degree), will the controller heat. This value can
also be configured through Advance Config parameter 7, please refer to the
part “Advance Config”.
Set the level of vibration sensor under the buttons or buzzer level. OFF:
vibration or buzzer off Low Level, High Level: low vibration or buzzer level,
high vibration or buzzer level. The level can also be configured through
Advance Config parameter 03.
The OLED display brightness when operate the device. High Level, Mid Level,
Low Level. This parameter can also be configured through Advance Config
parameter [22].
Once the device goes to standby interface, if there is no operation within
30s, the display will go off automatically.
Display Temperature Set
Other Set
Temperature Compensation
Re-power Status
Internal Over Heat Protection
Child Lock
Display Auto Off Function
Activation
This parameter defines which sensor temperature will be displayed on Home
page. Floor Temp: floor temperature (external sensor) . Home Temp: indoor air
temperature. This parameter can also be configured through Advance Config
parameter [23].
Select OTHER SET on Home Interface to enter into OTHER SET interface as
follow: Short press button to select the item you would like to modify, then
short press move up and down buttons to modify value of
selected item, then short press button F to save and quit, short
pressing button only quits without saving.
The displayed temperature may has big tolerance caused by the sensor or other
factors, so it is necessary to do temp compensation to room sensor and floor
sensor. Compensation range is -5 ~ +5°C, stepping is 0.5°C. This parameter can
a lso be configured through Advance Config parameter [11] and [12] .
Device state after reset power of the device. If set as “last status”, device
will go to the status before power failure after power on again. If set as
“default”, device will go to default mode after power on again. This parameter
can also be configured through Advance Config parameter [4].
To ensure the safety of the device, if the internal temperature of the device
(not displayed on the interface) is over a certain value during heating
process, the device will execute a short tempo rary action to turn off the
relay, and the icon will appea r on the interface, after the tempera ture
decreases to a certain value, the device will recover to work.
F Press and hold and buttons for over 10S,then the child lock
can be activated or cancelled. When child lock is activated, then icon will
appear on the display.
F On the Home Interface, press and hold both and
buttons for
over 10S, during the process, the icon will flash slowly, the Display
Auto OFF function can be enabled or disabled, when the function is
enabled, the icon will be displayed, otherwise the icon will not be
displayed.
This parameter can also be configured through Advance Config
parameter [27] .
Z-Wave Set Introduction
1 .Z-Wave Network Management
Select
ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow:
Adding to a Z -Wave Network ( Inclusion) Method 1: Select “Add”, then short press button , the device will send out inclusion request, “Status” will show “Inclusion…”. If there is no response from a gateway within 30 seconds, or inclusion failed, “Status” will show “Fail”. If included successfully, “Status” will show “Inclusion OK” and device ID. Method 2: Operate the gateway into inclusion mode, make sure the device is already removed from previous network, reset power of the device, the device will be included to the gateway automatically.
Smart Start If the user’s gateway also supports smartstart, add the device by
scanning the QR code, Smartstart allows users to quickly add devices to the
gateway by scanning the device’s QR code. After scanning to add the device,
reset power of the device or waiting for a while, the device will be added to
the gateway automatically. Please find the QR code on the casing of the
device.
Removing from a Z-Wave Network (Exclusion)
Select “Remove”, then short press button F , the device will send out
exclusion request, “Status” will show “Exclusion… If “.
there is no response from a gateway within 30 seconds, or exclusion failed,
“Status” will show “Fail”. If excluded successfull,y “Status” will show
“Exclusion OK” and device ID will be showed as 0.
Factory Reset (Reset) Factory resetting will reset all Advance Config
parameters to default value, and the device will be removed from the Z-Wave
network.
Select “Reset”, then short press button F, the device will start reset,
“Status” will show “Reset…”. If there is no response
from a gateway within 6 seconds, or exclusion failed, “Status” will show
“Fail”. If reset successfully, “Status” will show “Reset OK”. Note 1: if the
device is excluded or reset successfully, the Auto Mode Schedule will be reset
to default value. Note 2: the sent frame of inclusion and exclusion is INFO
frame.
2.Basic set command class Set the device operation mode as Comfort Mode
(Manual Mode) by sending command class basic set = 0XFF. Set the device
operation mode as OFF mode by sending command class basic set = 0x00
Z-Wave Technical Specifications
1.Supported Notification Report and Sensor Type
Notifcation Type
Triggering Event
Description
POWER_MANAGEMENT
POWER_MANAGEMENT_OVERCURRENT_DETECTED Over Current Alarm
Heat Alarm
Overheat detected
Over Heat Alarm
SENSOR MULTILEVEL Type support Air temperature
2. Technical Specifications Item SDK
Explorer Frame Support
Scale Celsius (¥)
Definition 6.82.00 Yes
Device Type Generic Device Class Specific Device Class
Role Type Routing
Thermostat(HVAC) GENERIC_TYPE_THERMOSTAT SPECIFIC_TYPE_THERMOSTAT_HEATING
Always On Slave (AOS)) Yes
ermostat Related Specifications
Command
Support
ThermostatMode ThermostatSetPoint
ThermostatMode_OFF(off) ThermostatMode_HEAT(UI displays Manual) ThermostatMode_DRY ThermostatMode_EnergyHeat(UI displays Auto) ThermostatMode_Away(UI displays Away) ThermostatSetPointType_Heating(set manual temperature) ThermostatSetPointType_Energy_Save_Heating(set auto temperature) ThermostatSetPointType_DRY ThermostatSetPointType_Away_Heating(set away temperature)
3. Supported Command Class Root Device
Suppourt Command class
Support S2/s0
COMMAND_CLASS_ZWAVEPLUS_INFO
V2
COMMAND_CLASS_SECURITY
V1
COMMAND_CLASS_SECURITY_2
V1
COMMAND_CLASS_TRANSPORT_SERVICE
V2
COMMAND_CLASS_SUPERVISION
V1
COMMAND_CLASS_THERMOSTAT_MODE
V3
YES
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
V1
YES
COMMAND_CLASS_THERMOSTAT_SETPOINT
V2
YES
COMMAND_CLASS_ASSOCIATION
V2
YES
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
V3
YES
COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_VERSION
V1
YES
V3
YES
COMMAND_CLASS_MANUFACTURER_SPECIFIC
V2
YES
COMMAND_CLASS_DEVICE_RESET_LOCALLY
V1
YES
COMMAND_CLASS_POWERLEVEL
V1
YES
COMMAND_CLASS_TIME_PARAMETERS
V1
YES
COMMAND_CLASS_CONFIGURATION
V1
YES
COMMAND_CLASS_NOTIFICATION
V8
YES
COMMAND_CLASS_METER
V3
YES
COMMAND_CLASS_MULTI_CHANNEL
V4
YES
COMMAND_CLASS_FIRMWARE_UPDATE_MD
V4
YES
Controlled command class COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT
Support S2/s0
V3
YES
V2
YES
Note: the EndPoint01 mirrors equivalent effect root endpoint. EndPoint1
command list:
Support command class COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION OMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
COMMAND_CLASS_THERMOSTAT_SETPOINT
COMMAND_CLASS_METER
EndPoint2 (floor temperature sensor) command list: Support command class
COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO
Support S2/s0 V2
V1
V1
V1
V5
YES
V2
YES
V3
YES
V1
YES
V3
YES
V1
YES
V2
YES
V3
YES
Support S2/S0
V2
V1
V1
V1
V5
YES
V2
YES
V3
YES
V1
YES
5.Association Root device
Group ID 1
NAME Lifeline
Profile
AGI_LIFE_LINE c0x0001
Max nodes 5
Description
1.Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices
of this group when factory reset the device. 2.Send Command Class
THERMOSTAT_SETPOINT_REPORT, THERMOSTAT_MODE_REPORT,
THERMOSTAT_OPERATING_STATE_REPORT to associated devices of this group When
operation mode and temperature change. 3.Send Command Class
NOTIFICATION_REPORT to associated devices of this group when over current,
over heat detected 4.Send Command Class METER_REPORT to associated devices of
this group to report metering parameters.
AGICONTROL
2
Heat Set
KEY01
5
(0x2001)
Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT_MODE_SET to control other temperature control devices when operation changes
EndPoint01 :
Group ID NAME
Profile Max nodes
1
Lifeline
AGI_LIFE_LINE c0x0001
0
Note: the EndPoint01 has equivalent effect of root function. EndPoint02
Group ID NAME
Profile Max nodes
1
Lifeline
AGI_LIFE_LINE c0x0001
0
Description Lifeline(0x0001)
Description Lifeline(0x0001)
6.Advance Config Parameters
Parameter Size Description
Default Parent Value Menu
0x02(2)
Over current detection max. value, unit is A. When detected current is
over this
1
value, the device will turn off the relay and send NOTIFICATION CC.
0, disable over current detection
5-16, over current detection max. value
16 Monitor Set
0x03(03) 0x04(4) 0x06(6)
Vibration level and buzzer level triggered by pressing buttons 0, disable
vibration and buzzer
1
1, Low Level
2, High Level
Whether to recover to settings before power failure or power reset
1
0, use default settings
1, recover to settings before power failure or power reset
Floor temperature detection max. value, unit is ¥ , when floor temperature
sensor is higher than this value, the device will turn off the relay and send
1
NOTIFICATION CC.
0, disable this function
1-35, the high temperature value
1
Other Set
1
Other Set
27 Monitor Set
0x07(7) 0x08(8)
1
Temperature control hysteresis value setting, setting range 0.5¥-5¥. value range is 5-50, unit is 0.1¥
Auto mode (Energy save mode) temperature schedule
1
0, use schedule set by user
1, use Energy _Save_Heating temperature set by THERMOSTAT_SETPOINT_SET
5
Monitor Set
0
None
0x09(9)
Select floor temperature sensor type
1, NTC/10K B(25/50°C)=3950
1
2, NTC/15K B(25/50°C)=3950
3, NTC/50K B(25/50°C)=3950
4, NTC/100K B(25/50°C)=3950
5, NTC/12K B(25/50°C)=3950
1
Other Set
0x0A(10)
Temperature control reference selection
1, room sensor
1
2, floor sensor
3, room+floor sensor
1
Other Set
0x0B(11) 0x0C(12) 0x0D(13)
0x0E(14)
1
ROOM SENSOR temperature compensation setting -10~10, unit is 0.5 ¥
FLOOR S ENSOR temperature compensation setting
1
-10~10, unit is 0.5 ¥
1
Set how long the drying mode lasts 5~100, unit is minute
Set the mode a fter the drying mode ends
0x00 = OFF
1
0x01 = Manual mode (comfort mode)
0x02 = Auto mode (energy save mode)
0x03 = Away mode
0
Other Set
0
Other Set
30
Dry Mode Schedule
2
Dry Mode Schedule
0x10(16)
When to report temperature relative change threshold value actively, unit
1
is 0.1¥ 0, d isab l e t o r ep or t
2- 10, rep or t when t he threshold v alue i s 2- 10
2
None
0x11(17) 0x12(18) 0x13(19) 0x14(20) 0x15(21) 0x16(22)
0x17(23) 0x18(24) 0x1B(27)
Time interval value for periodic report of temperature, humidity, unit is S
1
0, disable to report
30~28800, report when time interval value is 30~28800
When to report power change absolute threshold, unit is W
1
0, disable to report
1~100, report when absolute threshold is 1~100
When to report current change absolute threshold, unit is 0.1A
1
0, disable to report
1~10, report when absolute threshold is 1~10
When to report voltage change absolute threshold, unit is 1 V
1
0, disable to report
1~10, report when absolute threshold is 1~10
4
Time interval value for periodic active report of Meter 60-2678400 (31 days) , unit is S
The OLED display brightness when operate the device.
0, low level
1
1, mid level
2, high level
This parameter defines which sensor temperature will be displayed on
1
Home page. 0x00: indoor a ir temperature
0x01: external temperature (floor temperature)
The time zone that the time parameters command adopts is UTC, the time
1
zone need to be set:
+12 ~ -12
Enable or disable Display Auto Off function when the interface is standby
1
interface. 0, disbaled
1, enabled
300 (5mins)
None
5
None
10
None
2
600 (10mins)
None None
1
Other Set
0
Other Set
0
Other Set
0
Namron AS Nedre kalbakkvei 88B
1081 Oslo Norway
post@namron.com
NAMRON Z-WAVE RELÉ 16A
Important: Read All Instructions Prior to Installation Function introduction
S witch input
Action button
NC S
09.ZV09SAPSB.04739
LE D indica tor, indica tes when progra m the switch ( inclusion,
exclusion, fa ctory reset)
1 CH load output
Pro du c t Data Z – Wa ve F requency Input Volta ge Output Volta ge Output
Current
Opera ting tempera ture R ela tive humidity Dimensions
AC 100-240V power input
868.42 MHZ ( E U) AC100-240V AC100-240V 16A ma x. 0 to 40°C 8% to 80%
45.5x45x20.3mm
Load Symbol
Compatible Load T ypes
Load Type
Maximum Load
LED lamps with transformers
1220W @ 2 30V 580W @ 110V
LED drivers
Inca ndescent lighting, HV H a logen la mps
1220W @ 2 30V 580W @ 110V
3680W @ 2 30V 1760W @ 110V
Remarks
Due to va riety of LE D la mp designs, ma ximum number of LE D la mps is
further dependent on power fa ctor result when connected to switch.
Ma ximum permitted number of drivers is 1220W divided by driver na mepla te
power ra ting.
Max. continuous load 10A
Low volta ge ha logen lighting with electronic tra nsformers
E lectrica l a pplia nces such a s television, refrigera tor, wa ter hea ting
etc.
1220W @ 2 30V 580W @ 110V
3680W @ 2 30V 1760W @ 110V
Max. continuous load 10A
S afety & Warn in gs · DO NOT insta ll with power a pplied to device. · DO NOT
expose the device to moisture.
Quick Start How to insta ll: · S tep 1: power on the Z – Wa ve in- wa ll
switch. · S tep 2: a ctiva te inclusion mode on your Z – Wa ve controller. · S
tep 3: a ctiva te inclusion mode of the switch by triple press the a ction
button on the switch. T he switch will be included to Z – Wa ve network.
Pro du c t Des c riptio n T he in- wa ll switch is a Z – Wa ve device tha t is
used to switch ON/OF F the connected light or electrica l a pplia nces a nd ca
n be controlled by other Z – Wa ve devices. T he In- wa ll switch ca n be
included a nd opera ted in a ny Z – Wa ve network with other Z – Wa ve
certified devices from other ma nufa cturers a nd/or other a pplica tions. All
non- ba ttery opera ted nodes within the network will a ct as repea ters rega
rdless of vendor to increa se relia bility of the network.
T his device supports the S ma rtS ta rt inclusion. S ma rtS ta rt ena bled
products ca n be a dded into a Z – Wa ve network by sca nning the Z – Wa ve QR
C ode present on the product with a c ontroller providing S ma rtS ta rt
inclusion. No further a ction is required a nd the S ma rtS ta rt product will
be a dded a utoma tica lly within a p eriod a fter the QR c ode being sca nned
or reset power of the device. P lea se find the QR c ode on the device ca
sing.
T he encryption mode tha t the switch supports is S 2 Una uthentica ted. When
the switch is being included into a Z – Wa ve network, you ca n use your prima
ry controller/ga tewa y to ena ble encryption mode or disa ble encryption. ( T
he prima ry controller/ga tewa y sha ll support encryption mode configura
tion) . T he switch supports OTA a nd ca n upda te firmwa re wirelessly. In a
ddition, the switch is equipped with P ower Metering a nd over current
protection. Operation
Installation G uide P lea se rea d ca refully the enclosed user ma nua l
before insta lla tion of the in- wa ll switch, in order to ensure a n error-
free functioning.
ATTE NTION: P rior to the a ssembly of the product, the volta ge network ha s
to be switched OF F a nd ensured a ga inst re- switching.
Inclusion (adding to a Z-Wave network) 1. S et prima ry controller/ga tewa y
into inclusion mode ( P lea se refer to your prima ry controllers ma nua l on
how to turn your controller into inclusion) .
2. P ower on the in- wa ll switch a nd set it into inclusion mode. T here a
re two methods to set the in- wa ll switch into inclusion mode: 1) Triple
press the a ction button on the switch, LE D indica tor will fla sh ra pidly,
it will set the switch into inclusion mode for 30 seconds, if there is no
reply from the ga tewa y, the device will quit inclusion mode a fter 30
seconds. 2) When the va lue of pa ra meter 5 is configured a s 1, triple press
the externa l switch ra pidly within 1.5 seconds, LE D indica tor will fla sh
ra pidly, it will set the switch into inclusion mode for 30 seconds, if there
is no reply from the ga tewa y, the device will quit inclusion mode a fter 30
seconds.
T he LE D indica tor will sta y solid on for 3 seconds if the device is a dded
to the network successfully. T he indica tor will turn off if inclusion fa
ils.
Exclusion (removing from a Z-Wave network) T here a re two exclusion methods:
Method 1: E xclusion from the prima ry controller/ga tewa y a s follows: 1. S
et the prima ry controller/ga tewa y into exclusion mode ( P lea se refer to
your prima ry controllers ma nua l on how to set your controller into
exclusion) .
2. P ower on the in- wa ll switch a nd set it into exclusion mode. T here a
re two methods to set the in- wa ll switch into exclusion mode: 1) Triple
press the a ction button on the switch, LE D indica tor will fla sh ra pidly,
it will set the switch into exclusion mode for 30 seconds, if there is no
reply from the ga tewa y, the device will quit exclusion mode a fter 30
seconds. 2) When the va lue of pa ra meter 5 is configured a s 1, triple press
the externa l switch ra pidly within 1.5 seconds, LE D indica tor will fla sh
ra pidly, it will set the switch into exclusion mode for 30 seconds, if there
is no reply from the ga tewa y, the device will quit exclusion mode a fter 30
seconds.
T he LE D indica tor will sta y solid on for 3 seconds if the device is
removed from the network successfully. T he indica tor will turn off if
exclusion fa ils.
Method 2: F a ctory reset the switch will force the switch to be excluded from
a network. ( plea se refer to the pa rt “F a ctory R eset” of this ma nua l)
Note: F a ctory reset is not recommended for exclusion, plea se use this
procedure only if the prima ry controller/ga tewa y is missing or otherwise
inopera ble.
F ac to ry R es et P ress a nd hold down the a ction button for over 10
seconds, LE D indica tor fla shes slowly, the switch will resta rt a nd reset
to fa ctory defa ults.
S c en e C o n tro l Users ca n configure scenes using comma nd cla ss S C E
NE AC T UATOR C ONF S E T, a nd a ctiva te the scenes using comma nd cla
ss S C E NE AC T IVAT ION_ S E T.
As s o c iation Z – Wa ve devices control other Z – Wa ve devices. T he rela
tionship between one device controlling a nother device is ca lled a ssocia
tion. In order to control a d ifferent device, the controlling device needs to
ma inta in a l ist of devices tha t will receive controlling comma nds. T hese
lists a re ca lled a ssocia tion groups a nd they a re a lwa ys rela ted to
certa in events ( e.g. button pressed) . In ca se the event ha ppens a ll
devices stored in the respective a ssocia tion group will receive a c ommon
wireless comma nd.
As s oc iatio n G rou ps :
Associa tion Groups
Group Na me
Group 1
Lifeline
Ma x Nodes
5
Description
1. When press a nd hold down “R eset” button for 10S to reset the device,
send ” Device R eset Loca lly Notifica tion” to a ssocia ted devices of this
group to report fa ctory reset informa tion.
2. When over loa d detected, send ” NOT IF IC AT ION_ R E P ORT ” to a ssocia
ted devices of this group.
3. R eport energy meter a ctively.
4. S end ba sic report automa tica lly.
S et an d u n s et as s oc iatio n s : ( Note: All a ssocia tion informa tion
will be clea red a utoma tica lly once the switch is excluded from a network.)
S et associa tion by opera ting prima ry controller/ga tewa y to send pa ckets
to the switch: T he prima ry controller/ga tewa y sends pa ckets to the switch
using “C omma nd C la ss AS S OC IAT ION”
No de I n formatio n F rame T he Node Informa tion F ra me is the business ca
rd of a Z – Wa ve device. It conta ins informa tion a bout the device type a
nd the technica l ca pa bilities. T he inclusion a nd exclusion of the device
is confirmed by sending out a Node Informa tion F ra me. Beside this it ma y
be needed for certa in network opera tions to send out a Node Informa tion F
ra me. How to send out Node Informa tion F ra me: When the switch is set to
inclusion/exclusion mode a ga in, it will send out Node Informa tion F ra me,
there a re 2 kinds of opera tion a s follows: 1. Triple press the a ction
button, the dimmer will be set to inclusion/exclusion mode, then send out Node
Informa tion F ra me. 2. When the switch is under inclusion mode, there a re
two kinds of opera tion: 1) Triple press inclusion/exclusion button, the
switch will be set to inclusion mode a ga in, a nd send out Node Informa tion
F ra me. 2) P ower off and power on the switch, it will be set to inclusion
mode a utoma tica lly, a nd send out Node Informa tion F ra me.
Tec h n ic al D ata
Wireless R a nge SDK
E xplorer F ra me S upport Device Ty pe
Generic Device Class S pecific Device C la ss
R ole Ty pe R outing
up to 100 m outside, on a vera ge up to 40 m inside buildings 7.13.6.0 Yes
On/Off Power S witch G E NE R IC T Y P E S WIT C H BINARY S P E C IF IC
T Y P E P OWE R S WIT C H_ BINARY
Alwa ys On S la ve ( AOS ) Yes
S u ppo rted C omman d C las s Node I nfo
S ec u rity C o mman d S u ppo rted R epo rt
C OMMAND C LAS S Z WAV E P LUS _ INF O
V 2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V 2
C OMMAND C LAS S T R ANS P ORT _ S E RV IC E V 2
C OMMAND C LAS S V E R S ION
V3
C OMMAND C LAS S S E C UR IT Y
V1
C OMMAND C LAS S S WIT C H_ BINARY
V2
C OMMAND C LAS S S E C UR IT Y 2 C OMMAND C LAS S _ S UP E RV IS ION
V 1 C OMMAND C LAS S S C E NE AC T IVAT ION V 1 V 1 OMMAND C LAS S S C E NE AC T UATOR _ C ONF V 1
C OMMAND C LAS S ME T E R
V5
C OMMAND C LAS S NOT IF IC AT ION
V8
C OMMAND C LAS S C ONF IG UR AT ION
V1
C OMMAND C LAS S AS S OC IAT ION G R P INF O V 1
C OMMAND C LAS S AS S OC IAT ION
V2
C OMMAND C LAS S F IR MWAR E UP DAT E MD V 4
C OMMAND C LAS S P OWE R LE V E L
V1
C OMMAND C LAS S DE V IC E R E S E T LOC ALLY V 1
C OMMAND C LAS S INDIC ATOR
V3
Notific atio n R epo rt
No tific atio n T ype NOT IF IC AT ION T Y P E P OWE R MANA
G E ME NT ( 08) NOT IF IC AT ION T Y P E P OWE R MANA
G E ME NT ( 08)
Tr iggerrin g E ven t P OWE R MANAG E ME NT OV E R C UR R E NT
DETECTED(06) P OWE R MANAG E ME NT OV E R LOADE D N
T_DETECTED(08)
Over C u rren t Alarm: When connecting to resistive loa d, over current protection va lue is 16A.
Note: When over current or overloa d protection is ena bled ( va lue of configura tion pa ra meter 4 not configured a s 0) , if the device detects tha t the loa d current is over 16A or power is over 3700W, the rela y will be forced to off, unless reset power of the device, otherwise the device will a lwa ys be a t ala rm sta tus, a nd report ala rm every 60 seconds.
C on figu ratio n C o mman d C las s
P a ra meter
Size
Description Info: S a ving loa d sta te before power fa ilure
0x02(2)
0 shutoff loa d 1
1 turn on loa d
0x03(3)
2 sa ve loa d sta te before power fa ilure
Info: E na ble/disa ble to send the ba sic report to the Lifeline when the loa d sta te cha nged
1
0 Disa ble to send Ba sic report
0x04(4)
1 E na ble to send Ba sic report
E na ble/disa ble over current or over loa d protection, report a la rm when the loa d is over 16A if ena bled
1
0: disable
1: enable E xterna l switch type
0x05(5)
1
0: push button switch
1: norma l on/off switch
Added to a nd removed from a network through externa l switch ( when ena bles
this function, triple press the externa l switch to be a dded to or removed
from a network)
0x07(7)
0 – disable
1
1 – enable
Note: if this function is ena bled, when triple press the switch ra pidly, the
device will be set to inclusion or exclusion mode, then device sta tus will
not be reported ( ba sic report) d uring this process.
P ower cha nge a bsolute threshold report, report when the power cha nge va
lue is over the threshold, unit is W
0x0A(10)
1
0: disa ble a bsolute threshold report function
1- 255: va lue of the power cha nge a bsolute threshold, if power cha nge va lue is over the threshold va lue, report the power cha nge va lue using ME T E R _ R E P ORT
C urrent cha nge a bsolute threshold, unit is 0.1A
0x0B( 11)
0: disa ble a bsolute threshold function 1
1- 255: va lue of the current cha nge a bsolute threshold, if current cha nge
va lue is over the threshold va lue, report the current cha nge va lue using
ME T E R _ R E P ORT
Vo lta ge cha nge a bsolute threshold, unit is 1V
0x0C(12) 0x0d(13)
0: disa ble a bsolute threshold function 1
1- 255: va lue of the volta ge cha nge a bsolute threshold, if volta ge cha
nge va lue is over the threshold va lue, report the volta ge cha nge va lue
using ME T E R _ R E P ORT
Time cycle to report the va lues of energy
consumption, volta ge, current and loa d power
4
a ctively
60- 2678400 ( 31 da ys) , va lue of the time cycle, unit is S .
Defa ult Va lue 2 1 1 0
1
5 1 2 1800( 30mins)
Wirin g Diagram Notes f o r th e d iagrams : L – termina l for live lea d N – termina l for neutra l lea d L1 – o utput termina ls of the device ( controlling connected light source) S – termina l for externa l switch NC – N o C onnection
- With Normal On/Off Switch
NC S
L N
- With Single Push Button Switch
PUSH
NC S
L N
- With Multiple Push Switches for Multiple Control Points
PUSH
PUSH
NC S
- Connect With Socket
PUSH
NC S
Product Dimension
45 mm L N
L N GND
45.5 mm 20.3 mm
Namron AS Nedre kalbakkvei 88B