namron EL-4512748 Z-Wave Awning Controller 2A Instructions
- June 3, 2024
- NAMRON
Table of Contents
namron EL-4512748 Z-Wave Awning Controller 2A
Important : Read All Instructions Prior to Installation
Function introduction
Product Data
- Z-Wave Frequency 868.42 MHZ ( EU) /908.42 MHZ (US) /921.42 MHz (ANZ)
- Input Voltage AC100-240V
- Output Voltage AC100-240V
- Max. Load Current Resistive loads:4A Capacitive/inductive loads:2A
- Operating temperature 0 to 40°C
- Relative humidity 8% to 80%
- Dimensions 45.5x45x20.3mm
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
Quick Start
How to install:
- Step 1: power on the Z-Wave curtain motor controller.
- Step 2: activate inclusion mode on your Z -Wave controller.
- Step 3: activate inclusion mode of the curtain motor controller by triple press the network inclusion/exclusion button. The curtain motor controller will be included to Z-Wave network.
Product Description
The curtain motor controller is a universal, Z -Wave Plus V2-compatible,
electric motor controller. The device allows for controlling motors of roller
blinds and venetian blinds, which are single-phase AC-powered. The curtain
motor controller allows for the precise positioning of roller blind or
Venetian blind slats. Precise positioning is available for the motors equipped
with mechanic and electronic end switches. The device a lso allows for
controlling on/off of lights. The module may be controlled wirelessly, through
the Z-Wave network primary controller, or through the switch keys connected to
it. In addition, the curtain motor controller is equipped with Power Metering
and over current protection.
The curtain motor controller can be included and operated in any Z-Wave network with other Z -Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. If the user’s gateway a lso supports smartstart, add the device by scanning the QR code, Smartstart allows users to quickly add devices to the gateway by scanning the device’s QR code. After adding the device by scanning QR code, wait for a while or reset power of the device, the device will be added to the gateway automatically. P lease find the QR code on the casing of the device.
The encryption mode that the curtain motor controller supports is S2 Unauthenticated. When the device is being included into a Z -Wave network, you can use your primary controller/gateway to enable encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration) . The curtain motor controller supports OTA and can update firmware wirelessly.
Main Features:
- Compatible with any Z-Wave or Z -Wave+ Controller,
- Controlled by Sunricher EasyHome or any other Z -Wave controller,
- Advanced microprocessor control
- Active element: electromagnetic, micro-gap relay switch
- The device may be operated by momentary or toggle switches, and by dedicated roller blind control switches
- Connected motor’s current and historical power consumption measured
- Over current protection
- To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations
- The curtain motor controller supports OTA and can update firmware wirelessly
Installation Guide
Please read carefully the enclosed user manual before installation of the
curtain motor controller, in order to ensure an error-free functioning.
ATTENTION : Prior to the assembly of the product, the voltage network has
to be switched OFF a nd ensured against re-switching.
Inclusion ( adding to a Z -Wave network)
- Set primary controller/gateway into inclusion mode (Please refer to your primary controller’s manual on how to turn your controller into inclusion) .
- Power on the curtain motor controller and set it into inclusion mode. There a re two methods to set the roller shutter into inclusion mode:
- Triple press the network inclusion/exclusion button, it will set the curtain motor controller into inclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
- When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into inclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
- The curtain motor controller will be added to the Z-Wave network.
Exclusion ( removing from a Z-Wave network)
- Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion) .
- Power on the curtain motor controller and set it into exclusion mode. There are two methods to set the curtain motor controller into exclusion mode:
- Triple press the network inclusion/exclusion button, it will set the curtain motor controller into exclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
- When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into exclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
- The curtain motor controller will be removed from the Z-Wave network.
Factory Reset
Press and hold down network inclusion/exclusion button for over 10 seconds,
the curtain motor controller will be reset to factory defaults.
Configure Parameter 3 to S et Working Mode
-
When the parameter 3 value is configured a s 0, light mode: either S1 or S2 can control both Q1 and Q2, short pressing or holding down will be recognized automatically. For detailed configuration please refer to configuration parameter 7.
Note : when configured a s light mode, root point, endpoint 1 mirrors to relay 1 (Q1) , endpoint 2 mirrors to relay 2 (Q2) . -
When the parameter 3 value is configured a s 1, shutter mode without positioning: S1 and S2 a re only valid while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. If the command is sent by a gateway, it only supports upward on, downward off, stop, it does not support positioning percentage operation. Nodes mirror function: root point, endpoint 1 with the same function: control shutter upward and downward actions. Endpoint 2 has no function.
-
When the parameter 3 value is configured a s 2, shutter mode with positioning: S1 and S2 a re only valid while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF. When reaching any end’s positioning, both relays will be OFF. If the command is sent by a gateway, it supports positioning percentage operation. When the slat function of the shutter is enabled, a valid time should be set through the parameter 13,so that the slat rotation function can be supported. Nodes mirror function: rootPoint, endpoint 1 with the same function: control shutter upward and downward actions. Endpoint 2 controls the shutter’s slat, switch multilevel set=50 means to open the slat to the maximum extent.
Note : the connected curtain motor should support position restriction function, i.e. endpoint aware.
Positioning Calibration
Calibration is a process during which a curtain motor controller learns the
position of the limit switches and a motor characteristic. Calibration is
mandatory when the working mode of the curtain motor controller is Shutter
mode with positioning. Connect the controller to the motor according to wiring
diagram, there a re two calibration methods a s follows:
- Calibration through the calibration button, short press the button twice, calibration starts automatically, short press the button twice again, calibration will stop.
- Set the configuration parameter 6 value to 1, calibration starts automatically.
Note : after installing the curtain motor, first do position restriction setting according to its user manual, i.e. top end and bottom end, then use the curtain motor controller to do positioning calibration.
Scene Control
Users can configure scenes using command class SCENE_ACTUATOR_CONF_SET, and activate the scenes using command class SCENE_ACTIVATION_SET.
Activate Scenes Using Switch S 1 S 2
Users can configure configuration parameter 9 to decide whether to send scene
activation command using command class CENTRAL_SCENE_NOTIFICATION.
The scene ID and key a ttribute supported by switch S1 and S2 a re a s follows:
Switch Number | Support Action type | Scene ID | Key Attribute |
---|
S 1
| Short press once| 1| Key pressed once
Short press twice| 1| Key pressed twice
Short press 3 times| 1| Key pressed 3 times
Press and hold, release| 1| K ey held down a nd relea sed
S 2
| Short press once| 2| Key pressed once
Short press twice| 2| Key pressed twice
Short press 3 times| 2| Key pressed 3 times
Press and hold, release| 2| Key held down and released
Default configuration of CENTRAL_SCENE_CONFIGURATION_SET is Slow Refresh = 1(send Key Held Down every 55s when the switch is pressed and held down) .
Association
Z-Wave devices control other Z -Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed). In case the event happens all devices stored in the respective association group will receive a common wireless command.
Association Groups:
Rootpoint
Association Groups | Group Name | Max Nodes | Description |
---|
Group 1
| ****
Lifeline
| ****
5
| 1. When press and hold down “K 2” button for 10S to reset the device, send ” Device Reset Locally Notification” to associated devices of this group to report factory reset information.
2. When over load detected, send ” NOTIFICATION_ REPORT” to associated devices of this group.
3. Send METER_ REPORT actively.
4. When action of S1 and S 2 is detected, send CENTRAL SCENE NOTIFICATION.
5. Send SWITCH MULTILEVEL REPORT.
Endpoint 1
Association Groups | Group Name | Max Nodes | Description |
---|
Group 1
| ****
Lifeline
| ****
0
| ****
SWITCH MULTILEVEL REPORT
Endpoint 2
Association Groups | Group Name | Max Nodes | Description |
---|---|---|---|
Group 1 | Lifeline | 0 | **** |
SWITCH MULTILEVEL REPORT
Curtain Control Commands Mirror Description
Shutter mode with positioning | Shutter mode without positioning |
---|
Basic Set (Value=0xFF)
| Multilevel Switch Set (0xFF):
Restore most recent( not 0) level
| Multilevel Switch Set (0xFF): Open
Basic Set (Value=0x00)
| Multilevel Switch Set (0x00): close| Multilevel Switch Set (0x00): Close
Basic Set
( Value=0x01..0x63)
| ****
Multilevel Switch Set (0x01..0x63)
| Multilevel Switch Set( 0x01..0x63): Open
Basic Report (Current Value, Target Value, Duration)| Multilevel Switch Report
(Current Value, Target Value, Duration)| Multilevel Switch Report (Current
Value, Target Value, Duration)
Note : the Duration parameter of Multilevel Switch Set is invalid.
Set and unset associations:
(Note: All association information will be cleared automatically once the
curtain motor controller is excluded from a network.)
Set association by operating primary controller/gateway to send packets to the curtain motor controller: The primary controller/gateway sends packets to the curtain motor controller using “COMMAND_CLASS_ASSOCIATION” o r “COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION” .
Node Information Frame
The Node Information Frame is the business card of a Z -Wave device. It
contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node
Information Frame. Beside this it may be needed for certain network operations
to send out a Node Information Frame.
How to send out Node Information Frame:
When the curtain motor controller is set to inclusion/exclusion mode again, it
will send out Node Information Frame, there a re 2 kinds of operation a s
follows:
- triple press the K2 button, the curtain motor controller will be set to inclusion/exclusion mode, then send out Node Information Frame.
- When the curtain motor controller is under inclusion mode, there are two kinds of operation:
- Triple press K2 button, the curtain motor controller will be set to inclusion mode again, and send out Node Information Frame.
- Power off and power on the curtain motor controller, it will be set to inclusion mode automatically, and send out Node Information Frame.
Technical Data
Wireless Range | up to 100 m outside, on average up to 40 m inside buildings |
---|---|
SDK | 7.13.6.0 |
Explorer Frame Support | Yes |
Device Ty pe | Window Covering Position/Endpoint Aware |
Generic Device Class | GENERIC TYPE SWITCH_ MULTILEVEL |
Specific Device Class | SPECIFIC TYPE CLASS C MOTOR_ CONTROL |
Role Ty pe | Always On Slave ( AOS) |
Endpoint 1 device type:
GENERIC_TYPE_SWITCH_MULTILEVEL/SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Endpoint 2 device type:
GENERIC_TYPE_SWITCH_MULTILEVEL/SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Note : the root point mirrored by endpoint 1 has the same function a s
endpoint 1.
SUPPORTED COMMAND CLAS S
Root Device Command-List
Node Info| S u pp o r t S 2 / S
0
---|---
COMMAND CLASS ZWAVEPLUS INFO| V 2|
COMMAND CLASS SECURITY| V 1|
COMMAND CLASS SECURITY 2| V 1|
COMMAND CLASS TRANSPORT SERVICE| V 2|
COMMAND CLASS SUPERVISION| V 1|
| |
COMMAND CLASS SWITCH MULTILEVEL| V 4| YES
COMMAND CLASS ASSOCIATION| V 2| YES
COMMAND CLASS ASSOCIATION GRP INFO| V 1| YES
COMMAND CLASS VERSION| V 2| YES
COMMAND CLASS MANUFA CTURER SPECIFIC| V 2| YES
COMMAND CLASS DEVICE RESET LOCALLY| V 1| YES
COMMAND CLASS POWERLEVEL| V 1| YES
COMMAND CLASS CONFIGURATION| V 1| YES
COMMAND CLASS FIRMWARE UPDATE_ MD| V 4| YES
COMMANDCLASS NOTIFICATION| V 8| YES
COMMAND CLASS METER| V 3| YES
COMMAND CLASS MULTI CHANNEL| V 4| YES
COMMAND CLASS MULTI CHANNEL ASSOCIATION| V 3| YES
COMMAND C LASS S CENE ACTIVATION| V 1| YES
COMMAND C LASS S CENE ACTUATOR C ONF| V 1| YES
COMMAND C LASS C ENTRAL S CENE V 3| V 3| YES
COMMAND CLASS WINDOW_ COVERING| V 1| YES
Endpoint 1 Command-List
Node Info| S u pp o r t S 2 / S
0
---|---
COMMAND CLASS ZWAVEPLUS INFO| V 2|
COMMAND CLASS SECURITY 2| V 1|
COMMAND CLASS SECURITY| V 1|
COMMAND CLASS SUPERVISION| V 1|
| |
COMMAND CLASS SWITCH MULTILEVEL| V 4| YES
COMMAND CLASS ASSOCIATION| V 2| YES
COMMAND CLASS ASSOCIATION GRP INFO| V 1| YES
COMMAND CLASS MULTI CHANNEL ASSOCIATION| V 3| YES
COMMAND C LASS S CENE ACTIVATION| V 1| YES
COMMAND C LASS S CENE ACTUATOR C ONF| V 1| YES
COMMAND CLASS WINDOW_ COVERING| V 1| YES
Endpoint 2 Command List
Node Info| S u pp o r t S 2 / S
0
---|---
COMMAND CLASS ZWAVEPLUS INFO| V 2|
COMMAND CLASS SECURITY 2| V 1|
COMMAND CLASS SECURITY| V 1|
COMMAND CLASS SUPERVISION| V 1|
| |
COMMAND CLASS SWITCH MULTILEVEL| V 4| YES
COMMAND CLASS ASSOCIATION| V 2| YES
COMMAND CLASS ASSOCIATION GRP INFO| V 1| YES
COMMAND CLASS MULTI CHANNEL ASSOCIATION| V 3| YES
COMMAND C LASS S CENE ACTIVATION| V 1| YES
COMMAND C LASS S CENE ACTUATOR C ONF| V 1| YES
COMMAND CLASS WINDOW_ COVERING| V 1| YES
Notification Report
Notification Type | Triggerring E vent |
---|---|
NOTIFICATION TYPE POWER_ MANAGEMENT( 08) | POWER MANAGEMENT OVERCURRENT_ |
DETECTED( 06)
Over Current Alarm: When connecting to a resistive load over current value is 4 1A When connecting to a motor or capacitive load, over current value is 2.1A. Over-current LED will flash 400ms every 1 second, and relays will turn off.
CONFIGURATION COMMAND CLASS:
Parameter | Size | Description | Default Value |
---|
0x02( 2)
| ****
1
| Enable/disable the curtain motor controller to report state change percentage threshold ( report only when change
value at the specified percentage), if enabled, report when the value reaches both 0% and 99%. When the working mode is configured as light mode, as long as the state
changes, the state change percentage threshold will be reported. SWITCH MULTILEVEL REPORT
0: disable to report actively
1- 10: value to report, unit is one percent
| ****
5
0x03( 3)
| ****
1
| Working mode
0: light mode
1: Shutter mode without positioning 2: Shutter mode with positioning
| ****
2
0x04( 4)
| ****
1
| Enable/disable to save positioning percentage, record and save current positioning every time when the curtain moves to specified position, if the working mode is configured as light mode, record on/off state.
0x00: disable 0x01: enable
| ****
1
0x05( 5)
| ****
1
| Enable/disable over current protection
0: disable
1: enable, when over current detected, there are two methods to cancel a larm:
1. short press either switch button S 1 or S 2, the a larm will last at least 1 minute and then be cancelled.
2. re- power on the curtain motor controller
| ****
1
0x06( 6)
| ****
1
| Only value 1 can be written in, which means starting positioning calibration.
When read,
0x01: positioning calibration completed 0x00: positioning not calibrated
This parameter is only valid when parameter 3 configured as shutter mode with positioning.
| ****
0
0x07( 7)
| ****
1
| When parameter 3 value configured as 0 ( light mode), configuration of button S 1 and S 2 control.
Value=0
Short press S 1 to switch ON/OFF Q 1. Press and hold down S 1 to switch ON Q1, then release to switch OFF Q 1.
Short press S 2 to switch ON/OFF Q 2. Press and hold down S 2 to switch ON Q2, then release to switch OFF Q 2.
Value=1
Short press S 1 to switch ON/OFF Q 1. When S 1 is pressed and held down, then released, not processed.
Short press S 2 to switch ON/OFF Q 2. When S 2 pressed and held down, then released, not processed.
Value=2
Press and hold down S 1 to switch ON Q1, then release to switch OFF Q 1. When S 1 short pressed, not processed. Press and hold down S 2 to switch ON Q2, then release to switch OFF Q 2. When S 2 short pressed, not processed.
Value=3
Short press S 1 or S 2 to switch ON/OFF of both Q1 and Q2
| ****
0
| | simultaneously. When S 1 or S 2 pressed and held down, not processed
Value=4
Press and hold down S 1 to switch ON Q1 and Q2. When S 1 short pressed, not processed.
Press and hold down S 2 to switch OFF Q 1 and Q2. When S 2 short pressed, not processed.
|
---|---|---|---
0x08( 8)
|
1
| Enable/disable to add the device to or remove it from a Z- Wave network through button S 1. Please refer to the parts of inclusion and exclusion for details.
0: enable
1: disable
|
1
0x09( 9)
|
1
| Enable/disable to send scene activation command CENTRAL SCENE NOTIFICATION_ V 3 when the
switches S 1 and S 2 are pressed.
0: disable to send for action of both S 1 and S 2 1: enable to send for action of both S 1 and S 2 2: enable to send for action of only S 1
3: enable to send for action of only S 2
|
1
0x0A( 10)
|
1
| Power change absolute threshold report, unit is W 0: disable absolute threshold comparison function
1- 100: value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_ REPORT
|
10
0x0B( 11)
|
1
| Current change absolute threshold, unit is 0.1A
0: disable absolute threshold comparison function
1- 10: value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_ REPORT
|
1
0x0C( 12)
|
1
| Voltage change absolute threshold, unit is 1V
0: disable absolute threshold comparison function
1- 10: value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_ REPORT
|
2
0x0d( 13)
|
1
| Slats rotation time, unit is 0.1S 0: disable the function
5- 250 ( 0.5S- 25S): value of the slats rotation time
This parameter is only valid when parameter 3 configured as shutter mode with positioning.
|
0
0x0E( 14)
|
4
| Time cycle to report energy consumption value ( unit is KWH), U, I, W actively
60- 2678400 ( 31 days), value of the time cycle, unit is S.
|
3600 ( 1 hour)
Wiring Diagram
Notes for the diagrams:
- L – terminal for live lead
- N – terminal for neutral lead
- S 1 – terminal for switch key No. 1 ( enable to s et the device into inclusion/exclusion mode)
- S 2 – terminal for switch key No. 2
- Q1 – output terminal n o. 1 f or electrical motor
- Q2 – output terminal n o. 2 f or electrical motor
- K1 – positioning calibration button when working mode is configured as shutter mode with positioning or Venetian mode (up/down and s lats rotation)
- K2 – inclusion/exclusion button ( used to add or remove a device from the system)
Compatible Load Types
Documents / Resources
|
namron EL-4512748 Z-Wave Awning Controller
2A
[pdf] Instructions
EL-4512748, Z-Wave Awning Controller 2A, Awning Controller 2A, Z-Wave
Controller 2A, Controller 2A, Controller
---|---