namron 70110005 Zigbee Plugg Med Termostat Instruction Manual
- June 3, 2024
- NAMRON
Table of Contents
namron 70110005 Zigbee Plugg Med Termostat
Function introduction
Product Data
Zigbee profile | 0x0104( ZHA) |
---|---|
Device ID | 0x000A( Plug- in Unit) |
Radio Frequency | 2.4GHz |
Input Voltage | AC 200- 240V, 50/60Hz |
Max. Load | 16A |
Over Current Protection | 16.1A |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 114.8×54.8×74.7( mm) |
LED Indicator State | Definition ( 16.1A Over Current) |
--- | --- |
Flashes red slowly | Over current |
Stays solid orange | Load power > 2200W |
Stays solid yellow | Load power 2001- 2200W |
Stays solid green | Load power 1501- 2000W |
Stays solid cyan | Load power 1001- 1500W |
Stays solid blue | Load power <= 1000W |
Flashes purple slowly | Firmware updating via OTA |
Stays solid white at a low brightness | Load switched off |
- ZigBee smart plug based on the latest ZigBee 3.0 protocol
- Enables to control ON/OFF of the load, supports max. 16 scenes
- ZigBee end device that supports Touchlink commissioning
- Supports find and bind mode to bind a ZigBee remote
- It supports ZigBee green power and can bind max. 20 Zigbee green power switches
- Supports temperature measurement
- Supports over-current protection and power metering enables to report of power consumption to the gateway
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to the device.
- DO NOT expose the device to moisture.
Operation
- Plug the smart plug into the AC power source.
- This ZigBee device is a wireless receiver that commu nictates with a variety of ZigBee c compatible s ys tems. This receiver receives and is controlled by wireless radio signals from the c-compatible ZigBee system.
- Zigbee Network P airing through Coordinator o r Hu b ( Added to a Zigbee Network)
- Step 1: Remove the device from the previous Zigbee network if it has already been added to, otherwise pairing will fail. Please refer to the part “Factory Res et Manually”.
- Step 2: From your ZigBee Controller or hub interface, choose to add a lighting device and enter Pairing mode as instructed by the controller.
- Step 3: Short press the “Program” button 5 times continuously to set the device to network pairing mode, LED indicator will flash white fast.
- Step 4: LED indicator will flash white 6 times to indicate successful pairing. LED indicator will maintain the status before entering into network pairing mode if pairing fails.
- Touch Link to a Zigbee Remote
Step 1: Short press the “Prog” button 4 times (Or re-power on the device 4 times) to start Touchlink commissioning, 180S timeout. Once timeout, repeat the operation.
Note:
-
Directly Touch Link ( both not added to a ZigBee network), each device can link with 1 remote.
-
TouchLink after both are added to a ZigBee network, each device can link with max. 3 0 remotes.
-
To control by both gateway and remote, add remote and device to the network first then TouchLink.
-
After TouchLink, the device can be controlled by the linked remotes.
-
Removed from a Zigbee Network through Coordinator or Hub Interface
-
Factory Reset Manually
Step 1: Short press the “program” button 5 times continuously, and the plug will enter into network pairing mode.
Step 2: LED indicator will flash white fast and the plug will try to join a Zigbee network. -
Factory Reset through a Zigbee Remote ( Tou c h R es et)
Note: Make sure the device is already added to a network, and the remote added to the same one or not been added to any network.
Step 1: Re-power the device to start TouchLink Commissioning, 180 seconds timeout, and repeat the operation. -
Find and Bind Mode
Note: Make sure the device and remote are added to the same gateway that supports find and bind.
Step 1: Short press “Prog.” find and bind target node, 180 seconds timeout, repeat the operation. button 3 times to start to Find and Bind mode (LED indicator flashes white slowly) to find and bind target node, 180 seconds timeout, repeat the operation.
Step 2: Set the remote or touch panel (target node) into find and bind mode, and enable it to find and bind initiator, please refer to the corresponding remote or touch panel manual.
Step 3: There shall be an indication on the remote or touch panel that it binds the device successfully and can control it then. -
Learning to a Z igbee G reen P ower S witc h
Step 1: Short press the “Program” button 4 times to start Learning to GP switch mode (LED indicator flashes twice), 180 seconds timeout, repeat the operation.
Step 2: Set the green power switch into Learning mode, please refer to its manual. Step 3: LED indicator will flash twice to indicate successful learning. Then the switch can control the device. -
Delete Learning to a Zigbee Green Power Switch
Step 1: Short press the “Program” button 3 times to start deleting Learning to GP switch mode (LED indicator flashes slowly), 180 seconds timeout, repeat the operation.
Step 3: LED indicator will flash 4 times to indicate successful deleting.
Step 2: Set the paired green power switch into Learning mode, please refer to its manual. -
Setup a Zigbee Network & Add Other Devices to the Network ( No Coordinator Required)
Step 1: Short press the “Program” button 4 times to enable the device to set up a zigbee network (LED indicator flashes white twice) to discover and add other devices, 180 seconds timeout, repeat the operation.
Step 2: Set another device or remote or touch panel into network pairing mode and pair to the network, refer to their manuals.
Step 3: Pair more devices and remotes to the network as you would like, refer to their manuals.
Step 4: Bind the added devices and remotes through Touchlink so that the devices can be controlled by the remotes, refer to their manuals.
Note -
Each added device can link and be controlled by max. 3 0 added remotes.
-
Each added remote can link and control max. 3 0 added devices.
-
ZigBee Clusters the device’s supports are as follows:
Input Clusters-
0x0000: Basic • 0x0003: Identify • 0x0004: Groups • 0x0005: Scenes • 0x0006: On/off
-
0x0402: temperature measurement
-
0x0702: Simple Metering
-
0x0b04: Electrical Measurement
-
0x0b05: Diagnostics
-
0x1000: ZLL Commissioning
Output Clusters -
0x0003: Identify
-
0x0019: OTA
-
-
OTA
The device supports firmware updating through OTA and will acquire new firmware from the Zigbee controller or hub every 10 minutes automatically.
Importer:
Namron AS Nedre kalbakkvei 88B 1081 Olso Norway
Made in China.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>