namron Touch Z Wave 16A Termostat Instruction Manual
- June 3, 2024
- NAMRON
Table of Contents
Touch Z Wave 16A Termostat
Instruction Manual
Technical data
Z-Wave frequency | 868.42MHz (EU) |
---|---|
Operation voltage | 220-240V, 50/60Hz |
Maximum load | 16A |
Power consumption | <2W |
Ambient temperature | 0°C to 40°C (during operation) |
Temperature range | 0°C to 40°C |
Hysteresis | 0.5°C to 2°C (default 0.5°C) |
Floor sensor | NTC R25=10K±1%@25°C, B25/50=3950K±1%, (3m included) |
Floor sensors supp orted | NTC R25=10K±1%@25°C, B25/50=3950K±1% (factory |
setting)
NTC R25=12K±1%@25°C ,B25/50=3950K±1% )
NTC R25=15K±1%@25°C, B25/50=3950K±1%
NTC R25=50K±1%@25°C, B25/50=3950K±1%
NTC R25=100K±1%@25°C, B25/50=3950K±1%
Control modes| 1. Away 2. Auto 3. Manual 4. Drying 5. Off
Control types| Room sensor (factory default)
Floor sensor
Room + floor sensor
This parameter can also be configured through advance config parameter 10
IP rating| IP21
Relative humidity| 8% to 80%
Standard| EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1
EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,
EN 60730-1:2016+A1:2019,
EN 60730-2-19:2019+A1:2019+A2:2020,
EN 50663:2017;ETSI EN 301 489-1V2.2.3,
ETSI EN301 489-3V2.1.1 ETSI EN300 220-1 v3.1.1.,
ETSI EN300 220-2 V3.2.1
RED:2014/53/EU
Certificate| Z-Wave plus, CE, RED
Installation
a.Installation must be done by a qualified electrician.
b.Power supply must be turned off during installation.
- Wiring diagram
- Mounting
a. Remove the display unit and front cover by using a small screwdriver.
b. Insert the wires to the correct terminals as presented in the wiring diagram above. Suggested wire-stripping length is 8-10mm.
c. Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).
Symbol overview
Settings Menu
How to enter settings menu:
- Under Home Interface, meanwhile the device is at OFF mode , press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu.
- Short press move up and down button to select a settings item, then short press button F to enter selected item.
- Settings menu include, Preview menu, Z-Wave settings, Schedule, Monitor settings, Time/Date settings, Other settings.
Time Setting
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as
follow:
Short press button to select the item you would like to modify, then short
press up and down buttons to modify value of selected item, then short press
button F to save and quit, short pressing button only quits without
saving. 2. Preview interface
On Home Interface, user can enter into PREVIEW interface, the interface will
display some basic configurations, energy consumption, date, floor temperature
etc.
Control Mode
Short press button on Home Interface to switch operation modes: the icons of
Away, Auto, Manual, Drying, Off modes will be displayed alternatively for 3
seconds and last displayed mode will be selected, or just short press F
button to select a desired mode when the modes’ icon displayed alternatively.
Press and hold button on Home interface for over 3 seconds to select Away mode
directly, then Press and hold button for 3 seconds to quit Away mode.
-
Away Mode: the device will control the heating system according to the set temperature within the set period. User can set time to leave home and time to go home according to the requirements of themselves, and set how the device will control the temperature during this period.
1.1. If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode Temperature Schedule before the end time.
1.2. If away mode has already been activated, the values of end time for away mode are set as 0, the device will always execute current set temperature with no time limitation. The device will consider the mode as anti- freeze mode, the recommended temperature setting is 4-10°C. -
Auto Mode: the device will control the heating system according to the configured time schedule or Z-Wave protocol Energy_Save_Heating Setpoint.
2.1. When configuration parameter 8 value set as 1, the device will control the temperature of energy save mode according to the temperature set by Command Class Energy_Save_Heating Setpoint or set by using the move up and down buttons, following mentioned schedule will be invalid.
2.2. When configuration parameter 8 value set as 0, the temperature set by Command Class Energy_Save_Heating Setpoint and set by using the move up and move down buttons will both be invalid, Energy Save Mode will control temperature according to following user schedule.
For instance, if user would like to keep room temperature at 18C during 18:00-23:00 on every Monday, and keep room temperature at 20C after 22:30 on every Monday, then user can set schedule by himself.
Schedule setting method 1: user can enters into schedule on Z-Wave Set Interface, the schedule interface is as follows: Short press button to select “Auto Schedule”, then short press button F Schedule weekly setting interface. Schedule setting method 2: on Home Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly:
On Auto Mode Schedule weekly setting interface, use buttons and F to enter into schedule setting of a certain week as follows:
On Auto Day Schedule interface, short press button to select the time or temperature that you would like to modify, then short press move up and down buttons to modify value, then short press button F to save and quit, short pressing button only quits without saving.
For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error remind “Time setting error!!!”. The default time schedules are as follows: Monday-Friday| 7:30,24C-12:00,20C| Saturday-Sunday| 7:30,24C-12:00,20C
---|---|---|---
18:00,16C-22:30,18C| 18:00,18C-22:30,18C -
Manual Mode: the device will control the heating system according to current set temperature. The temperature can be set by move up and move down button on the Home interface, or configured by Z-Wave gateway.
-
Drying Mode: The device will judge the set temperature for heating within a short period of time.
I.e.: in order to dry the water in the bathroom in a short time, the device could be set to quickly heat to dry the floor. Enter the configuration interface as follow:
Duration: set how long the dry mode should lasts
After Mode: set the mode after the drying mode ends
Remain: shows the remaining time of the drying mode
For configuration method and modification, please refer to Automatic Mode (Energy Save Mode) Schedule: -
Off Mode: this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions, otherwise the device will not work, meanwhile the standby interface will only show room temperature.
Monitor Set| | The function of monitor set is real time monitor of over current, over heat and freezing. On Home Interface, short press MONITOR SET to enter into monitor set interface a s follows: Short press button to select the item would like to modify, then short press move up and down buttons to modify value of selected item, then short press F button to save and quit, short pressing button only quits without saving.
---|---|---
Over-current Alarm| | If current is over the set value, the relay will be forced to off by the device, and the state will be reported to the gateway. The over current alarm function can be disabled, which can be set directly through the device, or can be configured through Advance Config parameter 2 by setting the value as 0 to disable the function, please refer to the part “Advance Config”.
Note: When over current alarm is triggered, the beeper will beep, to cancel the alarm, just press and hold button for over 3 seconds or reset power of the device. After cancel manually, the relay will show heating forbidden icon within 120 seconds, but other operations are allowed.
---|---|---
Max floor temp| Warning Heat Hold Mode K to Cancel.| This function is similar to the function of “Internal Over Heat Protec- tion” described in chapter -
When the control type is configured as “Room+Floor sensor”, this function will be valid:
The alarm will be triggered when the floor sensor temperature > Max floor temp, the relay will be forced to off by the device, and the state will be reported to the gateway. The following indication figure will prompt on the display.
After the floor sensor temperature <(Max floor temp – Hysteresis), the alarm will be cancelled automatically and the device will restore to previous operation mode. To cancel the alarm manually, just press and hold button for over 3 seconds, but the relay will show heating forbidden icon within 120 seconds and the alarm will not be triggered again, after 120 seconds expire, the device will restore to previous operation mode and continue to detect alarm temperature.
This function can be disabled, which can be configured directly through the device, or can be configured through Advance Config parameter 6 by setting the value as 0 to disable the function, please refer to the part “Advance Config”.
Hysterersis| | To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature, which will cause that the controller may keep switching on/off the relay. Here hyster- ersis enables the controller to control the relay only when the sensor temperature is lower than the set temperature minus the hysteresis value , this value can be set.
For instance, when hysterersis is set as 0.5 degree, then only when current sensor temperature < (the set temperature – 0.5 degree), will the controller heat.
This value can also be configured through Advance Config parameter 7, please refer to the part “Advance Config”.
Key Vibration| | Set the level of vibration sensor under the buttons or buzzer level. OFF: vibration or buzzer off Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level. The level can also be configured through Advance Config parameter 03.
Set|
Display| | The OLED display brightness when operate the device. High Level, Mid Level, Low Level.
This parameter can also be configured through Advance Config parameter [22].
Brightness Set|
Display| | Once the device goes to standby interface, if there is no operation within 30s, the display will go off automatically.
Auto Off|
Z-Wave Set Introduction
- Z-Wave Network Management
Select ZWAVE INFO on Home Interface to enter into Z-Wave network management interface as follow:
Adding to a Z -Wave Network ( Inclusion)
Method 1: Select “Add”, then short press button , the device will send out
inclusion request, “Status” will show “Inclusion…”. If there is no response
from a gateway within 30 seconds, or inclusion failed, “Status” will show
“Fail”. If included successfully, “Status” will show “Inclusion OK” and device
ID.
Method 2: Operate the gateway into inclusion mode, make sure the device is
already removed from previous network, reset power of the device, the device
will be included to the gateway automatically.
Smart Start
If the user’s gateway also supports smartstart, add the device by scanning the
QR code, Smartstart allows users to quickly add devices to the gateway by
scanning the device’s QR code.
After scanning to add the device, reset power of the device or waiting for a
while, the device will be added to the gateway automatically. Please find the
QR code on the casing of the device.
Removing from a Z-Wave Network (Exclusion)
Select “Remove”, then short press button , the device will send out exclusion
request, “Status” will show “Exclusion… If ”. there is no response from a
gateway within 30 seconds, or exclusion failed, “Status” will show “Fail”. If
excluded successfully, “Status” will show “Exclusion OK” and device ID will be
showed as 0.
Factory Reset (Reset)
Factory resetting will reset all Advance Config parameters to default value,
and the device will be removed from the Z-Wave network.
Select “Reset”, then short press button , the device will start reset,
“Status” will show “Reset…”. If there is no response from a gateway within 6
seconds, or exclusion failed, “Status” will show “Fail”. If reset
successfully, “Status” will show “Reset OK”.
Note 1: if the device is excluded or reset successfully, the Auto Mode
Schedule will be reset to default value.
Note 2: the sent frame of inclusion and exclusion is INFO frame.
Basic set command class
Set the device operation mode as Comfort Mode (Manual Mode) by sending command
class basic set = 0XFF. Set the device operation mode as OFF mode by sending
command class basic set = 0x00
Z-Wave Technical Specifications
Supported Notification Report and Sensor Type
Notifcation Type | Triggering Event | Description |
---|---|---|
POWER_MANAGEMENT | POWER_MANAGEMENT_OVERCURRENT_DETECTED | Over Current Alarm |
Heat Alarm | Overheat detected | Over Heat Alarm |
SENSOR MULTILEVEL Type support | Scale | |
--- | --- | |
Air temperature | Celsius ( ℃) |
Technical Specifications
Item | Definition |
---|---|
SDK | 6.82.00 |
Explorer Frame Support | Yes |
Device Type | Thermostat(HVAC) |
--- | --- |
Generic Device Class | GENERIC_TYPE_THERMOSTAT |
Specific Device Class | SPECIFIC_TYPE_THERMOSTAT_HEATING |
Role Type | Always On Slave (AOS)) |
Routing | Yes |
Thermostat Related Specifications
Command | Support |
---|---|
ThermostatMode | ThermostatMode_OFF(off) |
ThermostatMode_HEAT(UI displays Manual)
ThermostatMode_DRY
ThermostatMode_EnergyHeat(UI displays Auto)
ThermostatMode_Away(UI displays Away)
ThermostatSetPoint| ThermostatSetPointType_Heating(set manual temperature)
ThermostatSetPointType_Energy_Save_Heating(set auto temperature)
ThermostatSetPointType_DRY
ThermostatSetPointType_Away_Heating(set away temperature)
Supported Command Class
Root Device
Suppourt Command class | Support 52/s0 | |
---|---|---|
COMMAND_CLASS_ZWAVEPLUS_INFO | V2 | |
COMMAND_CLASS_SECURITY | V1 | |
COMMAND_CLASS_SECURITY_2 | V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE | V2 | |
COMMAND_CLASS_SUPERVISION | V1 | |
COMMAND_CLASS_THERMOSTAT_MODE | V3 | YES |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE | V1 | YES |
COMMAND_CLASS_THERMOSTAT_SETPOINT | V2 | YES |
COMMAND_CLASS_ASSOCIATION | V2 | YES |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION | V3 | YES |
COMMAND_CLASS_ASSOCIATION_GRP_INFO | V1 | YES |
COMMAND_CLASS_VERSION | V3 | YES |
COMMAND_CLASS_MANUFACTURER_SPECIFIC | V2 | YES |
COMMAND_CLASS_DEVICE_RESET_LOCALLY | V1 | YES |
COMMAND_CLASS_POWERLEVEL | V1 | YES |
COMMAND_CLASS_TIME_PARAMETERS | V1 | YES |
COMMAND_CLASS_CONFIGURATION | V1 | YES |
COMMAND_CLASS_NOTIFICATION | V8 | YES |
COMMAND_CLASS_METER | V3 | YES |
COMMAND_CLASS_MULTI_CHANNEL | V4 | YES |
COMMAND_CLASS_FIRMWARE_UPDATE_MD | V4 | YES |
Note: the EndPoint01 mirrors equivalent effect root endpoint.
EndPoint1 command list:
Support command class | Support 52/s0 | |
---|---|---|
COMMAND_CLASS_ZWAVEPLUS_INFO | V2 | |
COMMAND_CLASS_SECURITY | V1 | |
COMMAND_CLASS_SECURITY_2 | V1 | |
COMMAND_CLASS_SUPERVISION | V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL | V5 | YES |
COMMAND_CLASS_ASSOCIATION | V2 | YES |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION | V3 | YES |
OMMAND_CLASS_ASSOCIATION_GRP_INFO | V1 | YES |
COMMAND_CLASS_THERMOSTAT_MODE | V3 | YES |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE | V1 | YES |
COMMAND_CLASS_THERMOSTAT_SETPOINT | V2 | YES |
COMMAND_CLASS_METER | V3 | YES |
EndPoint2 (floor temperature sensor) command list:
Support command class | Support 52/S0 | |
---|---|---|
COMMAND_CLASS_ZWAVEPLUS_INFO | V2 | |
COMMAND_CLASS_SECURITY | V1 | |
COMMAND_CLASS_SECURITY_2 | V1 | |
COMMAND_CLASS_SUPERVISION | V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL | V5 | YES |
COMMAND_CLASS_ASSOCIATION | V2 | YES |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION | V3 | YES |
COMMAND_CLASS_ASSOCIATION_GRP_INFO | V1 | YES |
Association
Root device
Group ID | NAME | Profile | Max nodes | Description |
---|---|---|---|---|
1 | Lifeline | AGI_LIFE_LINE | ||
(0x0001 ) | 5 | 1. Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to |
associated devices of this group when factory reset the device.
2. Send Command Class THERMOSTAT_SETPOINT_REPORT, THERMOSTAT_MODE_REPORT,
THERMOSTAT OPERATING STATE REPORT to associated devices of this group When
operation mode and
temperature change.
3. Send Command Class NOTIFICATION_REPORT to associated devices of this group
when over current, over
heat detected
4. Send Command Class METER REPORT to associated devices of this group to
report metering parameters.
2| Heat Set| AGICONTROL
KEY01
(0x20011| 5| Transfer Command Class THERMOSTAT_SETPOINT_SET THERMOSTAT MODE
SET
to control other temperature control devices when operation changes
EndPoint01:
Group ID | NAME | Profile | Max nodes | Description |
---|---|---|---|---|
1 | Lifeline | AGI_LIFE_LINE | ||
(0x0001) | 0 | Lifeline(0x0001) |
Note: the EndPoint01 has equivalent effect of root function.
EndPoint02
Group ID | NAME | Profile | Max nodes | Description |
---|---|---|---|---|
1 | Lifeline | AGI—LIFE—LINE | ||
(0x0001) | 0 | Lifeline(0x0001) |
Advance Config Parameters
Parameter| Size| Description| Default
Value| Parent Menu
---|---|---|---|---
0x02(21| 1| Over current detection max. value, unit is A. When detected
current is over this
value, the device will turn off the relay and send NOTIFICATION CC. 0, disable
over current detection
5-16, over current detection max. value| 16| Monitor Set
0x03(03)| 1| Vibration level and buzzer level triggered by pressing buttons 0,
disable vibration and buzzer
1,Low Level
2,High Level| 1| Other Set
0x04(41| 1| Whether to recover to settings before power failure or power reset
0, use default settings
1, recover to settings before power failure or power reset| 1| Other Set
0x06(61| 1| Floor temperature detection max. value, unit is C , when floor
temperature sensor is higher than this value, the device will turn off the
relay and send NOTIFICATION CC.
0. disable this function
1-35, the high temperature value| 27| Monitor Set
0x07(71| 1| Temperature control hysteresis value setting, setting range 0.5 C
-5 C . value range is 5.50, unit is 0.1 C| 5| Monitor Set
0x08(8)| 1| Auto mode (Energy save model temperature schedule
0, use schedule set by user
1, use Energy_Save_Heating temperature set by THEFtMOSTAT_SETPOINT_SET| 0|
None
0x09(9)| 1| Select floor temperature sensor type
1,NTC/10K B(25/50°0=3950
2,NTC/15K B(25/50°C)=3950
3,NTC/50K B(25/50°0=3950
4,NTC/100K B(25/50°C)=3950
5,NTC/12K B(25/50°C)=3950| 1| Other Set
Ox0A(10)| 1| Temperature control reference selection
1,room sensor
2,floor sensor
3,room+floor sensor| | Other Set
Ox08(11)| 1| ROOM SENSOR temperature compensation setting -10-10, unit is 0.5
C| 0| Other Set
OxOC(12)| 1| FLOOR S ENSOR temperature compensation setting -10-10, unit is
0.5 C| 0| Other Set
Ox0D113)| 1| Set how long the drying mode lasts 5-100, unit is minute| 30| Dry
Mode
Schedule
OxOE(14)| 1| Set the mode a tier the drying mode ends Ox00 = OFF
0x01 = Manual mode (comfort mode) 0x02 = Auto mode (energy save model 0x03 =
Away mode| 2| Dry Mode
Schedule
Ox10(16)| 1| When to report temperature relative change threshold value
actively, unit is 0.1 C
0,disabletoreport
2- 10, rep or t when t he threshold value i s 2- 10| 2| None
0x11(171| 1| Time interval value for periodic report of temperature, humidity,
unit is S 0, disable to report
30-28800, report when time interval value is 30-28800| 300
(5mins)| None
---|---|---|---|---
0x12(181| 1| When to report power change absolute threshold, unit is W 0,
disable to report
1-100, report when absolute threshold is 1-100| 5| None
0x13119)| 1| When to report current change absolute threshold, unit is 0.1A 0,
disable to report
1-10, report when absolute threshold is 1-10| 10| None
0x141201| 1| When to report voltage change absolute threshold, unit is 1 V 0,
disable to report
1-10. report when absolute threshold is 1-10| 2| None
Ox15121)| 4| Time interval value for periodic active report of Meter
60-2678400(31 days) . unit is S| 600
(10mins)| None
0x16122)| 1| The OLED display brightness when operate the device.
0, low level
1,mid level
2,high level| 1| Other Set
0x17123)| 1| This parameter defines which sensor temperature will be displayed
on Home page.
0x00: indoor a it temperature
0x01: external temperature (floor temperature)| 0| Other Set
0x18(241| 1| The time zone that the time parameters command adopts is OTC, the
time zone need to be set:
+12 – -12| 0| Other Set
0x18127)| 1| Enable or disable Display Auto Off function when the interface is
standby interface.
0, disbaled 1, enabled| 0|