namron 5419610 400W Panel Oven WiFi Instruction Manual
- June 1, 2024
- NAMRON
Table of Contents
the smarter choice
INSTRUCTION MANUAL
NAMRON PANELOVN WiFi
400W/600W/800W/1000W
5419610 400W Panel Oven WiFi
220-240V~ 50-60Hz IP24
Effect: | 400W/600W/800W/1000W |
---|---|
Operating voltage: | 220-240V~50-60Hz |
IP Rating: | IP24 |
Frequency: | 2.4GHz (2.412-2.472GHz) |
RF conducted power: | 18dBm |
Included 1.6 m cable and plug.
USE
USE WITH WIFI
- Insert the power plug and turn on the power switch. The display will show the temperature.
- Choose “ ” mode by pushing the “OK” button, hold the button until “ ” symbol is shown on the display.
- Keep pressing “OK” more than 5 seconds, then the icon will flash.
- Refer to below QR code for “Wifi Guide”.
WITHOUT PROGRAM
- Insert the power plug and turn on the power switch. The display will show the temperature.
- Choose Comfort mode (display “ ”) or ECO mode (display “ ”) by pushing the “OK” button, hold the button until “ “ or “ ” symbol on the display.
- When the environment temperature is below set temperature, the heater will start heating automatically. The heating icon will be shown in the display.
- Press “+” or “-”to set the desired temperature. The temperature can be adjusted between 5-35°C. Press and hold “+” or “-” to adjust the temperature in a faster speed.
- Factory default setting is COMFORT = 21°C;ECO = 17°C.
- Press”OK” to select “ ” to turn the appliance into standby.
USE WITH PROGRAM
-
TIME SETTING
1. Press “M” button to select”td” and short press “OK”button. The heater will enter Time setting interface.
2. Press “+”/ “-” to set the day of the week (choose from d1 to d7).
Press “OK” to save and enter hour setting.
3. Press “+”/ “-” to set the hour of the day (choose from 0 to 23).
Press “OK” to save and enter minute setting.
4. Press “+”/ “-” to set the minute (choose from 00 to 59).
Press “OK” to save.
The heater will go back to the working mode and temperature. -
PROGRAM SELECTION
Short press OK to choose P1 or P2 or P3 or P4.
P1 or P2 or P3 pre-set program mode
- Short press OK to select P1or P2 or P3.
- After flashing 5 seconds, the display will show set temperature.
P1,P2,P3 are default program with pre-set program as below:
Weekly modes | P1 (5-2) | Monday-Friday | Saturday-Sunday |
---|---|---|---|
P2 (6-1) | Monday-Saturday | Søndag/Sunday | |
P3 (7-0) | Monday-Sunday | ||
P4 (0-7) | Monday-Sunday | ||
Time and program setting | Event | 4 heating cycles | 2 heating cycles |
Time period | Comfort | Eco | Comfort |
Time | 6:00-9:00 | 9:00-16:00 | 16:00-23:00 |
Factory setting | 21°C | 17°C | 21°C |
P4 is a Customized weekly program
If you want to revise the P4 program, follow below steps:
-
Short press M button and choose Pr.
-
Press OK button enter P4 interface.
-
After entering P4 interface:
Step 1, set day of the week, display show d1, press + or – choose d1/d2/d3/d4/d5/d6/d7.Press OK button to confirm.
Step 2, set the hour of the day, display show 0H, press + or – choose COMFORT or ECO . Press OK button to confirm.
The Comfort mode works at the temperature of Comfort mode.
The ECO mode works at the temperature of ECO mode.
You can change the temperature of Comfort and ECO following steps in Use without wifi” No.2. -
Repeat above steps to set the rest day and hours of the week. Press OK to confirm. Display will flash 30s and then back to the interface of Pr. Pr interface will flash 10s. It means the setting is complete. The heater will work the program you have set.
*Checking of the whole program that you have set
Press M button and choose Pr, press and hold + and – button at the same time
for 5s, the display will roll out with the whole week program you have set.
After that, it will return to td interface and flash 10s. Then heater will be
back to working mode.
Temperature calibration| Short press “M” to select “C”. Short press “OK” to
enter C — temperature calibration setting
interface. “0” will show on the display as default. Press “+”/ “-” to set the
compensation temperature within ±5°C.
---|---
Adaptive start| Short press “M” to select “AS”. Press “OK” to enter Adaptive
Start setting interface. The screen will show “on” or “oF”. Press “+” or “-“
to change the selection. When “on” is selected, the Adaptive Start function is
activated. When “oF” is selected, the function is deactivated. Default setting
is “oF”.
This feature measures the thermal inertia of the room and turns on the heaters
in advance to ensure “comfort” temperature is reached at the set time. This
function can turn on the appliance for heating maximum 2 hours in advance.
Remarks: This function applies for P1, P2, P3 program only.
Memory function| After the power is turned off, the heater can memorize the
working set temperature before the power failure and continue to work. In the
event of a power disconnection, the heater will keep the internal clock
running 24 hours. If the power is disconnected for more than 24 hours, when
the power is turned on again, the heater will return to the last used
temperature, the internal clock will return to the default time and start
running again. The screen will flash, indicating that there is a power outage.
The blinking state will continue until any button is pressed to cancel the
blinking.
Adjustment of display brightness| Short press “M” to select LI. Press “OK” to
enter LI—screen brightness setting interface. You can adjust the brightness of
the screen. The default setting value is 3.
Press “+”/“-” to choose from grade 1 to 5. Grade 1 is the darkest while 5 is
the brightest.
Open window detection| Press and hold “+“ and ”OK“ for five seconds to enter
the open window detection settings. The open window icon will be flashing.
Then press “+”/”-”to choose «on» or «oF». Press “OK” or after five seconds
without operating the display, and the setting will be saved. The default
factory setting for this function is OFF.
If «on» is selected, the window detection function is activated and the open
window icon will be visible in the display. When temperature drop is detected,
the appliance will automatically enter anti-freeze mode (heater works at 7°C,
with open window icon flashing). If temperature rises, the appliance will go
back to previous working mode. You can also press any button to go back to
previous mode. Choose «OF» to deactivate the detection function.
Memory function| The heater has a memory function and will automatically
return to the desired temperature after a power cut.
Child Lock| Press and hold “M“ and ”–“ for five seconds, until “CC” shows on
the display. Child lock is now activated.
Repeat procedure to deactivate this function. Child lock can also be activated
/ deactivated in your smart hub.
Reset the thermostat to default| Press “+”, “M” button until display shows
“rE”, heater will be set back to the factory default setting.
Light on /off the display| Press and hold “–“ and ”OK“ for five seconds and the
display will flash three times. After 30 seconds without being operated, the
displays light will then turn off. Press any key to light it again.
Information before first time use| The heater should be set to maximal
temperature for 30 minutes to burn the element clean. Some smell may occur.
DO NOT COVER
SAFETY
Do not cover the heater surface, the heater can become very hot and must be placed at a safe distance from flammable material. Disconnect power during maintenance. If using an extension cord it must be as short as possible and be extended when the oven is on.
ICON OVERVIEW
| Window detector function| | Stand by
---|---|---|---
| Comfort mode| | Temperature
| Eco mode| | Wi-Fi
| Heating indicator icon| H| Hour
| P4 (free weekly personalized program)| | During this mode, the appliance
doesn’t heat up but clock settings are maintained.
| temperature calibration| | the window detector function will be deactivated
| adjustment of screen brightness| | the window detector function will be
activated
| adaptive start function| | factory default setting
| time setting| | Monday
| Comfort mode| | Tuesday
| ECO mode| | Wednesday
| fixed pre-set programs P1| | Thursday
| fixed pre-set programs P2| | Friday
| fixed pre-set programs P3| | Saturday
| free weekly personalized program| | Sunday
ASSEMBLY OF THE HEATER
- Drill holes in the wall. Distance between holes: See the form (a).
- Attach the clips onto the wall.
- Push the heater into the clips and use screws to thighten the clips.
(mm)
Watt | A | B |
---|---|---|
400W | 150 | 465 |
600W | 210 | 525 |
800W | 330 | 645 |
1000W | 420 | 735 |
MEASURES
Model identifier(s): 5419610,5419615
Item| Symbol| Value| Unit| | Item| Unit
Heat output| | Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat output| Pnom| 0.4| kW| | manual heat charge control, with
integrated thermostat| [no]
Minimum heat output (indicative)| P min| N/A| kW| | manual heat charge
control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output| Pmax,c| 0.4| kW| | electronic heat charge
control with room and/or outdoor temperature feedback| [no]
Auxiliary electricity consumption| | | | | fan assisted heat output| [no]
At nominal heat output| el max| 0| kW| | Type of heat output/room
temperature control (select one)
At minimum heat output| el min| 0| kW| | single stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00046| kW| | Two or more manual stages, no
room temperature control| [no]
| | with mechanic thermostat room temperature control| [no]
| | with electronic room temperature control| [no]
| | electronic room temperature control plus day timer| [no]
| | electronic room temperature control plus week timer| [yes]
| | Other control options (multiple selections possible)
| | room temperature control, with presence detection| [no]
| | room temperature control, with open window detection| [yes]
| | with distance control option| [yes]
| | with adaptive start control| [no]
| | with working time limitation| [no]
| | with black bulb sensor| [no]
Contact details| Namron AS
Nedre kalbakkvei 88 1081 Oslo Norway post@namron.com
Model identifier(s): 5419611,5419616
Item| Symbol| Value| Unit| | Item| Unit
Heat output| | Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat output| Pnom| 0.6| kW| | manual heat charge control, with
integrated thermostat| [no]
Minimum heat output (indicative)| P min| N/A| kW| | manual heat charge
control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output| Pmax,c| 0.6| kW| | electronic heat charge
control with room and/or outdoor temperature feedback| [no]
Auxiliary electricity consumption| | | | | fan assisted heat output| [no]
At nominal heat output| el max| 0| kW| | Type of heat output/room
temperature control (select one)
At minimum heat output| el min| 0| kW| | single stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00046| kW| | Two or more manual stages, no
room temperature control| [no]
| | with mechanic thermostat room temperature control| [no]
| | with electronic room temperature control| [no]
| | electronic room temperature control plus day timer| [no]
| | electronic room temperature control plus week timer| [yes]
| | Other control options (multiple selections possible)
| | room temperature control, with presence detection| [no]
| | room temperature control, with open window detection| [yes]
| | with distance control option| [yes]
| | with adaptive start control| [no]
| | with working time limitation| [no]
| | with black bulb sensor| [no]
Contact details| Namron AS
Nedre kalbakkvei 88 1081 Oslo Norway post@namron.com
Model identifier(s): 5419612,5419617
Item| Symbol| Value| Unit| | Item| Unit
Heat output| | Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat output| Pnom| 0.8| kW| | manual heat charge control, with
integrated thermostat| [no]
Minimum heat output (indicative)| P min| N/A| kW| | manual heat charge
control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output| Pmax,c| 0.8| kW| | electronic heat charge
control with room and/or outdoor temperature feedback| [no]
Auxiliary electricity consumption| | | | | fan assisted heat output| [no]
At nominal heat output| el max| 0| kW| | Type of heat output/room
temperature control (select one)
At minimum heat output| el min| 0| kW| | single stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00046| kW| | Two or more manual stages, no
room temperature control| [no]
| | with mechanic thermostat room temperature control| [no]
| | with electronic room temperature control| [no]
| | electronic room temperature control plus day timer| [no]
| | electronic room temperature control plus week timer| [yes]
| | Other control options (multiple selections possible)
| | room temperature control, with presence detection| [no]
| | room temperature control, with open window detection| [yes]
| | with distance control option| [yes]
| | with adaptive start control| [no]
| | with working time limitation| [no]
| | with black bulb sensor| [no]
Contact details| Namron AS
Nedre kalbakkvei 88 1081 Oslo Norway post@namron.com
Model identifier(s): 5419613,5419618
Item| Symbol| Value| Unit| | Item| Unit
Heat output| | Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat output| Pnom| 1| kW| | manual heat charge control, with
integrated thermostat| [no]
Minimum heat output (indicative)| P min| N/A| kW| | manual heat charge
control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat output| Pmax,c| 1| kW| | electronic heat charge
control with room and/or outdoor temperature feedback| [no]
Auxiliary electricity consumption| | | | | fan assisted heat output| [no]
At nominal heat output| el max| 0| kW| | Type of heat output/room
temperature control (select one)
At minimum heat output| el min| 0| kW| | single stage heat output and no
room temperature control| [no]
In standby mode| el SB| 0.00046| kW| | Two or more manual stages, no
room temperature control| [no]
| | with mechanic thermostat room temperature control| [no]
| | with electronic room temperature control| [no]
| | electronic room temperature control plus day timer| [no]
| | electronic room temperature control plus week timer| [yes]
| | Other control options (multiple selections possible)
| | room temperature control, with presence detection| [no]
| | room temperature control, with open window detection| [yes]
| | with distance control option| [yes]
| | with adaptive start control| [no]
| | with working time limitation| [no]
| | with black bulb sensor| [no]
Contact details| Namron AS