Fluidmaster K-7530-5000 Toilet Install Kit Installation Guide

June 6, 2024
FLUIDMASTER

K-7530-5000 Toilet Install Kit
Installation GuideFluidmaster K 7530 5000 Toilet Install
Kit HOW-TO VIDEO
VISIT: FLUIDMASTER.COM
K-7530-5000 PRODUCT PAGE

GETTING STARTED

PARTS OVERVIEW
TOOLS NEEDED

Fluidmaster K 7530 5000 Toilet Install Kit - figure 1

CLICK SEAL® CONNECTOR
20” Toilet Connector

Fluidmaster K 7530 5000 Toilet Install Kit - figure 2

STEP 1: REMOVE OLD TOILET

A: TURN OFF WATER

B: DRAIN WATER
Flush the toilet to drain most of the water from the tank and bowl.

C: REMOVE CONNECTOR
Remove the water supply connector from the bottom of the fill valve and from the wall.

D: REMOVE TOILET CAPS
Then unscrew hex nuts to release the toilet bowl from the floor.

E: REMOVE OLD BOLTS FROM
THE TOILET FLANGE

F: CLEAN BOTTOM OF TOILET
Scrape off the wax with a putty knife and wipe clean. No wax residue should remain.

STEP 2: PLACE SETFAST™ BOLTS

NOTE: Pre-assemble SetFast (if needed). Thread stud into anchor nut, 2 or 3 turns only. White Dot, “thread locker”, must be closest to top.

A: SLIDE YELLOW LOCK WASHER (D) UP.

B: INSTALL BOLT (A) INTO FLANGE SLOT.
When positioned, pull bolt up and press down on yellow lock washer (D) to secure.

STEP 3: FLANGE HEIGHT

A: DETERMINE FLANGE HEIGHT
Check if flange is above, even with or below floor. If flange is below the floor, use ruler to determine flange depth.

B: PROCEED TO THE CORRESPONDING SECTION IN STEP 4 FOR YOUR FLANGE HEIGHT.Fluidmaster K 7530 5000 Toilet Install Kit - figure
13

STEP 4: FLANGE & SEAL INSTALLATION

FLANGE ABOVE FLOOR RUBBER SEAL INSTALLATION
A: REMOVE SPACER FROM SEAL.

The spacer will not be used for above-floor installs and can be discarded.

B: INSTALL SEAL OVER FLANGE.
Slide seal holes over bolts. Proceed to Step 5.Fluidmaster K 7530 5000
Toilet Install Kit - figure 15

FLANGE EVEN WITH OR UP TO 1/4” BELOW FLOOR INSTALLATION

A: INSTALL SPACER OVER FLANGE.
Slide seal holes over bolts.
Important: Foam side of spacer must face down as pictured or leaks may occur.

B: INSTALL SEAL ON TOP OF SPACER.
Slide bolt holes over bolts.
Proceed to Step 5.

FLANGE MORE THAN 1/4” BELOW FLOOR INSTALLATION
NOTE:
For a flange depth greater than ½” a flange extender is required. (2nd seal purchased separately)

A: INSTALL TWO SEALS ON TOP OF THE SPACER.
Slide spacer holes over bolts. Then slide each of the seal bolt holes over bolts. Important: Foam side of spacer must face down as pictured or leaks may occur.
Proceed to Step 5.

STEP 5: TOILET INSTALLATION

A: SET BOWL.
Position toilet bowl over the seal, guiding holes in toilet base over bolts.
NOTE: Toilet can be repositioned on the seal, if needed, unlike traditional wax rings.
NOTE 2: If toilet rocks, do not force by overtightening the bolts. Locate shims to firmly secure the toilet (see next page). Fluidmaster K 7530 5000
Toilet Install Kit - figure 19

STEP 6: SECURE TOILET

A: INSTALL THREADED CAP BASE ONTO BOLT, FLAT SIDE DOWN.

B: PLACE ANTI-SPIN WASHER INSIDE THREADED CAP BASE.

C: THREAD ACORN NUT INTO BOLT
Tighten until nut engages “thread locker” dot and it’s snug (bolt will self- adjust height). Use a wrench to tighten an additional ¼” turn. CAUTION: DO NOT OVERTIGHTEN.  Overtightening can cause a bowl or flange to crack.
NOTE: If toilet rocks, do not force by overtightening the bolts. Locate shims to firmly secure the toilet (see option below).

D: SCREW SECURE CAP™ ON THE THREADED CAP BASE.
(OPTIONAL) Shim toilet if needed

A: PLACE A LEVEL ON THE BOWL
Determine which side of the toilet is sloping.Fluidmaster K 7530 5000 Toilet
Install Kit - figure 24

B: PLACE SHIMS
Gently slide the shim(s) under the toilet with your hand until the rocking stops. CAUTION: Don’t use tools or force the shims.
This could cause you to lift the toilet, creating extra space that shouldn’t be there.

C: CUT THE ENDS
Carefully cut the ends of the shims with a knife so that the edges are not visible.

D: CHECK ACORN NUT
Make sure the acorn nuts are still securely tightened. Retighten if necessary. CAUTION: DO NOT OVERTIGHTEN. Overtightening can cause bowl or flange to crack.

A: CHOOSE THE CORRECT ADAPTER
Try attaching adapters to the water supply valve then inserting the adapter thread-side first into the metal nut.Fluidmaster K 7530 5000 Toilet Install
Kit - figure 28

B: THREAD THE METAL NUT ON
CLICK SEAL® CONNECTOR ONTO THE WATER SUPPLY VALVE.
Tighten ½ turn beyond hand tight.

**C: GENTLY TURN CLICK SEAL® NUT CLOCKWISE***
The “click” lets you know it’s sealed!

*D: SLOWLY TURN ON WATER AT THE SHUTOFF VALVE.**
Note: Carefully check for leaks at the shutoff valve. If the leak appears, tighten the nut just enough to provide a leak-free joint.

* DO NOT OVERTIGHTEN. DO NOT USE TOOLS ON PLASTIC NUTS OR PLASTIC FILL VALVES.
Overtightening and/or the use of tools could cause damage and lead to failure of the nut and/or fill valve. Such damage may not be visible to the eye. Failure of the nut and/or ill valve can lead to significant water leakage and water damage.

STEP 8: FLUSH THE TOILET

A: FLUSH THE TOILET
If you’re satisfied with the flush, YOU’RE DONE!

YOU DID IT!
We knew you could!
Share your success story
with friends and family!

#FixedMyToilet
#Fluidmaster

WARNING
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING BLEACH OR CHLORINE. Use of such products will: (1) RESULT IN DAMAGE to tank components and MAY CAUSE FLOODING and PROPERTY DAMAGE and (2) VOID FLUIDMASTER WARRANTY.
Fluidmaster Flush ‘n Sparkle Toilet Bowl Cleaning System is recommended for those choosing to use in-tank bowl cleaners and WILL NOT VOID the FLUIDMASTER WARRANTY because it will not damage the components. DO NOT overtighten nuts or tank/bowl may crack. Always use quality Fluidmaster parts when installing or repairing. Fluidmaster will not be responsible or liable for use of non- Fluidmaster parts during installation or repair.
LIMITED TEN-YEAR EXPRESS WARRANTY
Subject to the “Exclusions” set forth below, Fluidmaster Inc. promises to the consumer to repair, or at the option of Fluidmaster Inc. to replace any part of this plumbing product that proves to be defective in workmanship or materials under normal use for ten years from the date of purchase. All costs of removal, transportation, and reinstallation to obtain warranty service shall be paid by the consumer. During this “Limited Ten Year Express Warranty,” Fluidmaster Inc. will provide, subject to the “Exclusions” section set forth below, all replacement parts free of charge, necessary to correct such defects. This “Limited Ten Year Warranty” is null and void if this plumbing product has not been installed and maintained in accordance with all written instructions accompanying the product, and if non-Fluidmaster Inc. parts are used in the installation.
EXCLUSIONS: FLUIDMASTER INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING COSTS OF INSTALLATION, WATER DAMAGE, PERSONAL INJURY, OR FOR ANY DAMAGES RESULTING FROM ABUSE OR MISUSE OF THE PRODUCT, FROM OVERTIGHTENING OR FROM FAILURE TO INSTALL OR MAINTAIN THIS PLUMBING PRODUCT IN ACCORDANCE WITH THE WRITTEN  INSTRUCTIONS, INCLUDING USE OF NON-FLUIDMASTER PARTS. DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING BLEACH  OR CHLORINE. THE USE OF SUCH PRODUCTS WILL RESULT IN DAMAGE TO TANK COMPONENTS AND MAY CAUSE FLOODING AND PROPERTY  DAMAGE. USE OF SUCH PRODUCTS WILL VOID THIS WARRANTY.

ADDITIONAL QUESTIONS?
For installation assistance, contact our technical services department.
EMAIL, CHAT or CALL our toll-free number.
www.fluidmaster.com/support 1-800-631-2011
Hours Available: Monday – Friday 5:30 AM – 5:00 PM PST
30800 Rancho Viejo Road, San Juan Capistrano, CA 92675
www.Fluidmaster.com800-631-2011
Contact Fluidmaster for troubleshooting help or visit www.Fluidmaster.com
M-F 5:30 am – 5:00 pm PST.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals