WARNING (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position. -
Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides.
Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. -
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and nonabrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
TOOLS REQUIRED (NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING:
(C) Mounting plate (1)
(D) Green ground screw (1)
(E) Canopy (1)
(F) Knob nut (2)
(G) Tube (1)
(H) Iron frame (1)
(I) Nut (8)
(J) Bolt (8)
(K) Glass shade (4)
(L) Stem (1)
(M) Sockets assembly (1)
ACCESSORIES & QTY ENCLOSED:
(A) Plastic wire connector (3)
(B) Mounting screw (2)
ASSEMBLY & INSTALLATION INSTRUCTIONS:
1. Carefully remove the fixture from the carton and check that all parts and
accessories are included as shown in the above illustration.
2 »Unscrew knob nuts (F) from canopy (E), then gently removemounting plate (C)
from canopy (E) and set them aside for later installation.3 »1) Pass the fixture wires through iron frame (H), tube (G)
and canopy (E), then tighten stem (L) onto the top of sockets assembly (M) and
the bottom of iron frame (H).
2) Then screw tube (G) onto canopy (E) and the top of iron
frame (H). 4. Turn off power
Before you start the installation, NEVER attempt any work without shutting off
the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
5 » Carefully pass the supply wires through mounting plate (C).
Secure mounting plate (C) to the outlet box with mounting screws (B).
NOTE: the side of mounting plate (C) marked “GND” must
face out.
6 » Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS
BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the below chart
Connect wires according to the below chart
Conned Black or Red Supply Wire to: | Connect White Supply Wire to: |
---|---|
Black | White |
*Parallel cord ( round & smooth ) | *Parallel cord ( square & ridged ) |
Clear,Brown,Gold or Black without tracer | Clear,Brown,Gold or Black with |
tracer
Insulated wire ( other than green) with copper conductor| Insulated wire (
other than green ) with silver conductor
*Note: When parallel wires (SPT I & SPT II ) are used. The neutral wire
is square shaped or ridged and the other wire will be round in shape or smooth
( see illus.) Twist wires together with plastic wire connectors until
tightly joined, and wrap each connector with approved electrical tape. Be sure
that no wire strands are exposed and then carefully tuck all wires into the
outlet box.
7 » Raise canopy (E) over the outlet box. Align canopy (E) with the
preassembled mounting screws, then secure canopy (E) with the previously
removed knob nuts (F) till snug. Note: canopy (E) should be snug against the
ceiling and knob nuts (F).
If not, adjust the threaded length on mounting plate assembly
(C):
- First, unscrew the preassembled hex nuts
- Then, screw the preassembled screws in or out of mounting plate (C)
- When the secure length is achieved, tighten the hex nuts and back to step 7.
8 » 1) Remove nuts (I) and bolts (J) from iron frame (H), and carefully place
glass shades (K) on iron frame (H), then secure them with nuts (I) and bolts
(J).
2) Install bulbs (not included) (Please do not exceed the
maximum wattage recommended on the socket.)
9. Check everything is already installed properly, then you could turn on the
light. Enjoy!