Fluidmaster PRO1000A-037 PRO Series Universal Side Entry
Product Information
The PRO1000A-037 PRO SERIES UNIVERSAL SIDE-ENTRY CISTERN with LINK & SEAT is a cistern tank designed for installation in a bathroom. It comes pre-installed with various components such as the cistern plug, button, outlet valve, and inlet valve. The cistern tank has a flush volume conversion system that allows you to adjust the flush volume settings to either 4.5/3L, 6/3L, or 9/4.5L. The cistern tank also includes additional parts such as the link, seat with link connection plate, flush pipe coupling nut, seat bolt, seat plate, seat nut, fixed hole screw, Kee-Seal, wall anchor, double cone washer flush pipe wedge seal, pan entry flush pipe, and mid/high flush pipe.
Product Usage Instructions
Pre-Installation
- Open the lid of the cistern tank.
- If you want to convert the flush volume system to 6/3L or 9/4.5L, remove the black cistern tank spacer.
- To adjust the float settings for the desired flush volume conversion, remove the flush valve body and refer to the Flush Volume Conversion Table.
- Re-install the flush valve body and black cistern tank spacer, ensuring proper full and half flush alignment.
Installation
- Mark the wall for screw holes based on the fixed hole screw locations for your desired cistern height.
- Set the screws in place using wall anchors if necessary.
- Trim or cut the flush pipes as needed for your specific installation type.
- Lubricate the kee-seal with soap and water, then insert the flush pipes and connect them to the pan.
- Fit the flush pipe coupling nut and double cone washer wedge seal onto the flush pipe, hand-tighten the coupling nut, and secure the flush pipe to the outlet valve shank. Do not overtighten.
- Hang the cistern tank in place.
- Connect the water supply line to the cistern tank using approved fittings. Hand-tighten only, do not overtighten.
- Turn on the water and check for leaks.
- Flush the cistern to check the tank water level. The water level should be at the water line WL-Side Entry mark after the tank is filled.
Note: The blue button represents the half flush, while the white button represents the full flush.
CISTERN TANK OVERVIEW
TOP DOWN VIEW
PARTS OVERVIEW
PRE-INSTALLATION
- **A: OPEN LID
**
-
B: FLUSH VOLUME CONVERSION
CONVERTING TO 6/3L OR 9/4.5 FLUSH VOLUME SYSTEM-
B1: Remove black cistern tank spacer.
-
B2: Remove flush valve body & adjust full and half float settings per Flush Volume Conversion Table
-
**CISTERN FLUSH VOLUME CONVERSION SETTINGS
-
**
* **B3:** Re-install flush valve body and black cistern tank spacer. Ensure proper full and half flush alignment.
CHOOSE DESIRED INSTALL METHOD
INSTALLATION
- **STEP 1: MARK WALL FOR SCREW HOLES
**
- **STEP 2: SET SCREWS
**
- STEP 3: INSTALL FLUSH PIPES
- Trim / Cut Flush Pipes as needed per install type.
Note: C1 Install type (with link) shown. For install types C2 or C3, no cutting required on 90° elbow (FM9) or Mid/High (FM10) Flush Pipes.
- Trim / Cut Flush Pipes as needed per install type.
* Lubricate kee-seal with soap and water.
Insert flush pipes and connect to pan.
* Fit Flush pipe coupling nut and double cone washer wedge seal onto flush pipe. Hand-tighten Flush pipe coupling nut and secure flush pipe to outlet valve shank.
DO NOT OVERTIGTHEN
- **STEP 4: HANG CISTERN TANK
**
-
STEP 5: WATER SUPPLY CONNECTION & FINE-TUNE TANK WATER LEVEL
-
Turn on water & flush water supply line.
-
Turn off water & connect water supply line to cistern with approved fittings. Hand-tighten only.
DO NOT OVERTIGHTEN. -
Turn on water & check for leaks.
-
FLUSH THE CISTERN TO CHECK THE TANK WATER LEVEL
After the water stops filling the tank, the water level should be at the water line “WL-Side Entry” mark to ensure a proper flush.
-
-
STEP 6: ATTACH LINK (IF REQUIRED)
-
Secure link into position.
-
Set seat onto link to mark desired seat end point & cut point.
-
If cut required, cutting line guides reference on back of link as needed.
-
-
STEP 7: INSTALL SEAT
-
Insert Seat Bolt Plates in Connection plate (follow arrow guides).
-
For Link Application
Insert link to seat connection plate. Set seat bolts into pan holes and hand- tighten seat bolt nuts. -
For Non-Link Application
Set seat bolts into pan holes and handtighten seat bolt nuts.
-
-
STEP 8: ALIGN INLET VALVE
Ensure PRO75 Side-Entry Inlet Valve Body & Float are Aligned / Leveled Correctly-
Incorrect Position
Inlet valve body / float should not touch the side walls of the cistern tank. -
Correct Position
Inlet Valve body / float should be centered with cistern tank walls.
-
-
**STEP 9: ATTACH / RE-SECURE LID
**
TROUBLESHOOTING
-
Turn off water supply.
-
Flush cistern.
-
Unsnap tank water level adjustment screw from cap arm.
-
Rotate cap 1/8 turn counterclockwise to unlock cap & pull out.
-
Cup your hand in front of uncapped valve to prevent splashing.
-
Turn water supply on and off a few times.
-
Turn water supply off.
-
Replace valve cap.
-
Place cap assembly on valve body by engaging lugs & rotating 1/8 turn clockwise to locked position.
-
Snap tank water level adjustment screw back on cap arm.
-
-
Turn water supply on.
WARNING
- DO NOT USE IN-CISTERN DROP-IN TOILET BOWL CLEANERS CONTAINING BLEACH OR CHLORINE. Use of such products will: (1) RESULT IN DAMAGE to Cistern components and MAY CAUSE FLOODING and PROPERTY DAMAGE and (2) VOID FLUIDMASTER WARRANTY.
- DO NOT overtighten nuts or cistern/bowl may crack. Always use quality Fluidmaster parts when installing or repairing. Fluidmaster will not be responsible or liable for use of non-Fluidmaster parts during installation or repair.
WARRANTY
- Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
- You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
- To present claims under this warranty, please contact your place of purchase or contact Fluidmaster Australia Holdings Pty Ltd. NOTE: Original proof of purchase required.
- Warranty excludes incorrect installation. Installation shall be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2 (Install with licensed plumber; any installation processed without licensed plumber will void warranty) 5 Year Parts Replacement / 1 Year Parts & Labor Warranty.
- Only clean with soap and warm water to maintain quality finish. Do not use harsh chemical cleaners.
ADDITIONAL QUESTIONS?
For installation assistance, contact our technical services department.
EMAIL, or CALL our toll-free number
- Phone: +61 (03) 8870 2555
- Toll Free: 1 800 931 166
- IN NEW ZEALAND Call 09 415 5585
- Email: salesau@fluidmaster.com
- Website: www.Fluidmaster.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>