AKO-59810 Temperature and Humidity Logger Instructions
- June 5, 2024
- AKO
Table of Contents
AKO AKO-59810 Temperature and Humidity Logger Instructions
5981H002 Ed.02
AKO-59810
AKO-59811
AKO-59820
AKO-59821
Description
Temperature and moisture monitor with built-in NBIoT communication. Logs temperature and moisture data and transmits it to the cloud (akonet.cloud). Both the configuration and monitoring of the data are carried out in the cloud itself.
Display and analysis of the logged data
Both the display of the logged data and the device configuration must be done in the akonet.cloud.portal. The portal also allows you to analyse the stored data using graphs, statistics and operating indicators. For more information visit akonet.cloud.
Declaration of conformity
AKO Electromecánica S.A.L. hereby declares that the type of radioelectric
device AKO-598xxx (Temperature and moisture monitor, external NTC probe,
battery and built-in NB-IoT) is in accordance with Directive 2014/53/EU.
The full text of the EU conformity declaration is available at the following
Internet address:
http://help.ako.com/assets/uploads/DUEC598xxx.pdfSimplifih
Warnings
- If the device is used without adhering to the manufacturer’s instructions, the device safety requirements could be compromised. Only probes supplied by AKO should be used for the appliance to operate correctly.
- The device should be installed in a place protected from vibrations, water and corrosive gases, where the ambient temperature does not exceed the value indicated in the technical data.
- For the reading to be correct, the probe should be used in a place without heat influences apart from the temperature you want to measure or control.
- Avoid installing the device on metal walls or near devices that may cause radio emissions.
- AKO-59811x / 59821x devices should NEVER be operated without installing the external antenna.
- This device can be fitted with any antenna provided it has a gain of less than 9.2 dBi and there is a minimum distance between it and any person or animal of more than 20 cm.
- This device must always be installed in an area where a minimum distance of 20 cm from the human body is ensured, to guarantee compliance with human exposure to electromagnetic fields.
- Any type of antenna used with the equipment must comply with the limits established in the radio interface of the member estates and the following documents: Commission Decision 2010/267/EU of 6 May 2010,ECC Decision (09)03 of 30 October 2009 and CEPT Report 30 of 30 October 2009.
- This device is powered by a non-rechargeable battery, if it runs out it must be replaced with the model AKO-58030.The dead battery cannot be disposed of with household waste, it must be taken to a select collection point. NEVER try to recharge the battery, perforate or hit the battery or immerse it in liquids or dispose of the battery with fire.
Installation
Installation conditions: Install the device away from draughts and condensation. Do not locate it close to evaporators, condensers or other items that may produce electromagnetic noise. If it is installed in a chamber, locate it as close as possible to the door. If it is installed inside a cabinet or any other piece of furniture, locate it as close as possible to its door.
Activation of the device
Before activating the device, make sure that there is enough reception at the installation location. Activated devices may not be returned.
- -Access akonet.cloud (requires registration).
- -Register the new device by pressing and following one of these two methods:
- Manually enter the serial no. and the activation code that appear on the device’s label.
- Press and capture the QR code of the device’s label (requires that the PC or mobile device used for accessing akonet.cloud has a camera).
- -Once both steps have been completed, activate the device by pressing the pushbutton for 9 seconds. The 3 indicator lights flash.
- -Wait until the process has finished (approximately 3 min). If the green LED lights up, transmission is OK and the device has been activated correctly. If the red LED lights up, transmission has failed.The device will make 2 more attempts in the course of 1 hour and will try again once a day. If the problem persists, check coverage in your area or change the location of the device.
Operation
Pushbutton
Long press ( > 9 sec.): Activate the initial start-up of the device. This
should only be done after registering in akonet.cloud.
When activated,the 3 indicators flash and during transmission the blue
indicator flashes.
Medium press ( > 3 sec.): Forces data transmission to akonet.cloud. When it wakes up, the 3 indicators flash and during transmission the blue indicator flashes.
Short press ( < 3 sec.): Displays the status of the battery with the green indicator:
ON: Battery OK
Flashing: Low battery, replace as soon as possible.
Indicators
Display the status of the device only after a medium press (forced transmission),the rest of the time they remain off.
RED
Flashing: An error has been detected in the operation, after 3 seconds
the indicator turns off.
Constant: The transmission could not be carried out, review the coverage,
after 3 seconds the indicator turns off.
GREEN
At the end of a transmission, it indicates the level of current coverage:
Constant: Good signal quality
Flashing: Medium signal quality
Flash: Poor signal quality
After 3 seconds the indicator turns off.
BLUE
Flashing: Transmission in progress
Logging and sending data
The device is shipped from the factory in an inactive state, therefore it does not transmit or log any information until it is activated (see “Registering the device”).
Once active, the device logs the temperature, moisture, alarms and external probe temperature (depending on model) data at regular intervals. The time between each log is defined by the option “L2 – Data logger interval frequency”under the heading “Parameters / dlG – Datalogger”of akonet.cloud.
The sending of logged data to akonet.cloud takes place when it meets one of the following criteria:
- The elapsed time defined using the “Tx – Cloud transmission interval”,defined in paragraph “Parameters / nb – Narrowband”,has run out.
- An alarm has been detected with forced transmission configuration.
- A transmission has been forced with a medium press.
For more information on the operation of akonet.cloud and on how to configure the device, consult manuals 5000H001 and 5000H011 respectively.These are available on our website www.ako.com.
Technical specifications
Power supply: Battery LiSOCI2,3.6 Vdc,6.5 Ah
Estimated life of the battery: up to 8 years*
Measuring range
Internal temperature probe: EN12830, S,C,2,-40 to 50 ºC
External temperature probe: EN12830, S,C,1,-50 to 50 ºC
Moisture: 0 to 100 %
Resolution
Temperature: 0.1 ºC
Moisture: 0.1 % RH
Precision
Internal temperature probe: -30 to 0 ºC:±1 ºC, 0 to 50 ºC: ±0.5 ºC
External temperature probe: ±1 ºC
Moisture: 20 to 80 % RH:±2 %
Rest: ±5 %
Banda: NBIoT (Narrow band,B20 for Europe)
Tx: 832 – 862 MHz;Rx:791 – 821 Mhz
Maximum transmission power: 23.5 dBm conducida
Antenna
AKO-59810x / 59820x: Internal
AKO-59811x / 59821x: External
This device is UNE EN 12830 compilant
Working ambient temperature: -40 to 50 ºC
Storage ambient temperature: -40 a 60 ºC, recommended +30 ºC
Range of moisture permitted: 0 – 100 % RH (without condensation)
Protection degree
AKO-59810x / 59820x: IP68
AKO-59811x / 59821x: IP65
Dimensions: 107 mm (W) x 85 mm (H) x 39 mm (D)
*Battery life may vary depending on the ambient temperature, the level of coverage and the configuration of the device.
akonet.cloud
AKO ELECTROMECÁNICA, S.A.L.
Avda. Roquetes, 30-38
08812 • Sant Pere de Ribes.
Barcelona • Spain.
Tel.: +34 902 333 145
Fax: +34 938 934 054
www.ako.com
We reserve the right to supply materials which may be slightly different from those described in our Data Sheets. Updated information on our web.
355981002 REV.01 2021
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>