SCHLAGE AD-200 Offline Commercial Keypad Lock Instruction Manual
- June 6, 2024
- Schlage
Table of Contents
SCHLAGE AD-200 Offline Commercial Keypad Lock
Installation Instructions
-
Prepare door.
IMPORTANT! See template. Additional door preparation may be required. -
Identify model of lock.
AD-200 Printed on box label. Choose steps to perform by models listed in corner. -
Install door position switch (DPS).
Ensure alignment on door and jamb. -
Route RS-485 cable and power wires.
-
If not using batteries (standard option), route power wires.
-
When retrofitting, install RX switch. Install in existing 98/99 exit device.
-
Install sex bolts to secure device.
-
Install grommet.
-
Route RX wires.
-
Install device per manufacturer instructions.
For proper function, cam must be in down position. -
Install spindle into assembly
-
Install reader.
-
Check lever handing.
-
Install cylinder and lever.
Verify tailpiece is horizontal.
Keyed Lever -
Install outside assembly.
-
Install inside assembly.
-
Connect white DPS wires.
-
Connect ribbon cable.
-
If RX, insert plug.
-
Install RS-485 communication module.
Install lower cover. -
Install wireless communication module.
-
Apply power, AD-200/250/400 only. Optional Torx® security screws are included.
Hardwired option: See user guide for wiring details. -
Carefully remove insulator strip from battery.
-
Install cover and screws.
-
Set up lock. After installing the lock, see the user guide for setup and operation.
Lever removal
Changing the cylinder’s tailpiece
Rehanding
-
Remove USB plug.
-
Remove cover from baseplate.
NOTE : on keypad only applications, reader is not removable! -
Remove spring cage.
-
Move lever stop to opposite side − Align arrow with latch.
-
Reinstall springcage.
IMPORTANT: Verify that the correct size screw is used. -
Reassemble cover, baseplate, and mounting plate.
IMPORTANT : Do not pinch the ribbon cable during reassembly.