ACCESSORIES

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 1

SPECIFICATIONS

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 2

Shielded wiring cable

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 3

3-core unshielded wiring cable+75-3 video wiring cable: Connect the shield of the 75-3 video wiring cable with the GND of the 3-core unshielded wiring cable.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 4

4.If user wants to use CAT5 or CAT6 network cable, effective distance from the outdoor camera to the furthest indoor monitor will be limited. For unshielded network cable, the distance will be up to 20m. For shielded network cable, the distance will be up to 40m. So CAT5 or CAT6 network cable is not recommended. CAT5 or CAT6 network cable consists of 4 pairs of twisted pairs(8 wires), here one pair of twisted pair will be used as one cable. Green&White+Green, Brown&White+Brown, Orange&White+Orange, Blue&White+Blue.

Unshielded network cable:

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 5

Shielded network cable:
Connect the shield of the network cable with the GND.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 6

WIRING DIAGRAM

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 7

Note:
One intercom kit supports up to 4 monitors, but we suggest to connect 3 monitors. Because the cable is too long, the image will be black and white on the monitor.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 8

The default mode of the monitor is Master mode.
Multiple monitors connected, ensure that the wiring and settings are correct as follows.

  1.  Connect from “Out” port of Master monitor to the “In” port of Slave monitor. Connect from “Out” port of the last monitor to the “In” port of the next monitor.
  2.  Set as Slave mode for all the Slave monitors

DESCRIPTION ON INDOOR UNIT

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 11

Package Contents(Please check actual model)

Model: MZ-VDP-NA200

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 12

Model: MZ-VDP-NE120

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 13

Overview

Model: MZ-VDP-NA200

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 14TMEZON MZ-VDP-739EM 4-Wire Video Door Phone
15

Model: MZ-VDP-NE120

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 16

Specification

Model: MZ-VDP-NA200

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 17

Model: MZ-VDP-NE120

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 18.

Wiring diagram

The power supply of the outdoor doorbell is supplied with an indoor monitor. User can connect electronic control lock to the doorbell, the lock can be connected with the door lock port.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 19

The terminal is defined functionality as below:

  1. Video
  2. GND
  3. Audio
  4. Power(DC 12V)
  5. Unlock: Connect to door lock.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 20

The terminal is defined functionality as below:

  1. Power(DC 12V)
  2. Audio
  3. Unlock: Connect to door lock.
  4. GND
  5. Video

The installation process of outdoor units

Model: MZ-VDP-NE120

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 22

Connect To The Electronic Control Lock

You can connect different electronic control lock to the outdoor doorbell, first you need to buy a power supply controller for the lock, a electronic control lock. You can connect an electronic lock, or an electric mortise lock, or a magnetic lock, or a cathode lock. Please refer to the following diagram to connect the monitor, the outdoor doorbell, the power supply for the door lock and the electronic control lock. L+: The positive of the lock, L-: the Negative of the lock. The power supply controller is power for the electronic control lock. For an electronic lock, please connect L+ port to NO port of the power supply controller, connect L- port to COM port of the power supply controller, connect GND port to GND port of the power supply controller, connect 12V port to 12V port of the power supply controller. For an electric mortise lock, or a magnetic lock, or a cathode lock, please connect L+ port to NC port the power supply controller, connect L- port to COM port of the power supply controller. For all the locks, please connect GND port and PUSH port of the power supply controller to the 2 pin cable connected to the unlock ports of the outdoor doorbell. Also you can install a push switch for the lock, please connect positive line of the switch to PUSH port of the power supply controller, connect negative line to GND port of the power supply controller.

Note on door lock connection

The electric locks are usually divided into NC lock and NO lock, their wiring is different, the NC lock need to work with the additional power supply control.

Note:

  1. The doorbell or the monitor will not provide the power to door lock.
  2. The doorbell can support door locks within 30V.
  3. Door lock’s power supply depends on its door lock, if the door lock is 12V, the corresponding power supply is 12V, etc.
  4. Make sure the input voltage from the monitor to the outdoor doorbell must reach 11.7V when unlocking.

NO Lock: Always closed when power or power off, only open when press unlock. NC Lock: Always open when power off. Closed when power and open after press unlock.

TMEZON MZ-VDP-739EM 4-Wire Video Door Phone 23

Note:
Since this manual is a multilingual version, some specific operations are omitted. If you have any questions, please send an email to: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TMEZON User Manuals

Related Manuals