Beam DistributionImportant Safety Information

  • This product must be installed by a licensed electrician in accordance with AS/NZS 3000. Disconnect electricity before any installation.
  • No part of the luminaire should be modified, if the luminaire is damaged it should be returned to Trend Lighting.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
  • To maintain Ingress Protection on IP65 Rated luminaires, ensure the fitting is installed in accordance with the installation instructions and the mounting surface is able to provide an adequate seal as per Step 3.

INSTALLATION

Approvals
The RCM Marking on this product applies to AS/NZS CISPR15:20011 Limits and methods of radio disturbance characteristics of electrical lighting and similar equip-ments. This product is designed in accordance with AS/NZS60598 Luminaires, general requirements and tests.

Model No

| Input Voltage| Power (W)| Colour Temperature| CRI| Ingress Protection
---|---|---|---|---|---
XDF153| 220-240| 15| 3000K| 90+| IP65
XDF154| 220-240| 15| 4000K| 90+| IP65
XDF155| 220-240| 15| 5000K| 90+| IP65
XDF253| 220-240| 25| 3000K| 90+| IP65
XDF254| 220-240| 25| 4000K| 90+| IP65
XDF255| 220-240| 25| 5000K| 90+| IP65
XDF353| 220-240| 35| 3000K| 90+| IP65
XDF354| 220-240| 35| 4000K| 90+| IP65
XDF355| 220-240| 35| 5000K| 90+| IP65
XDF553| 220-240| 55| 3000K| 90+| IP65
XDF554| 220-240| 55| 4000K| 90+| IP65
XDF555| 220-240| 55| 5000K| 90+| IP65

Before Installation
Be sure to read this installation pamphlet in its entirety before commencing installation.
Always ensure mains power is switched OFF before commencing any electrical work.

  • Step 1
    Cut Out

    • XDF15: 120mm
    • XDF25: 120mm
    • XDF35: 150mm
    • XDF55: 150mm
      Please note: Ensure the cut-out corresponds with the selected fitting.
  • Step 2

  • Step 3TREND-XDF153-Ceiling-Light-fig-3
    Bend springs upward and installs luminaire into the ceiling. Once installed the springs should clamp down on the ceiling to support the fixture.
    To maintain IP65 rating ensure the luminaire is installed on flat, level ceilings and the silicone gasket has an adequate seal to the mounting surface.
    Ensure both the driver and luminaire are not covered with any material.

Installation Notes

DO NOT COVER
MANUFACTURER’S RECOMMENDATION:

  • NO BARRIER REQUIRED
  • OBSERVE CEILING CLEARANCES
    Do not cover the luminaire or driver with thermally insulating material. You can however, safely abut timber rafters to simplify layout but a 50mm minimum clearance must be kept around the light fitting from ceiling insulation.

Ceiling Clearance

Documents / Resources

| TREND XDF153 Ceiling Light [pdf] Instruction Manual
XDF153, XDF154, XDF155, XDF253, XDF254, XDF255, XDF153 Ceiling Light, XDF153, Ceiling Light, Light
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

trend User Manuals

Related Manuals