Switch
120 V~ 50 / 60 Hz
Lighting Load – 8 A
Motor Load – 1/4 HP 5.8 A
Companion Switch (for 3-way wiring)
120 V~ 50 / 60 Hz 8.3 A

Help

Use our mobile-friendly self-paced installation tool:
www.lutron.com/wiringwizard
Find more product information: www.lutron.com/support
– Videos
– Frequently Asked Questions
– Online Chat (8 am – 5 pm EST)
Call us: U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico +1.888.235.2910
Others +1.610.282.3800

Turn power OFF at the circuit breaker

WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off power at the circuit breaker or fuse before installing.

IMPORTANT

  1. CAUTION: Use only with permanently installed fixtures with screw-in LED, self-ballasted compact fluorescent, halogen, or incandescent lamps. Use only to control the primary side of permanently installed transformer supplied low-voltage lighting, or in combination with incandescent lamps. To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles.

  2. Neutral is required for all load types.

  3. Install in accordance with all national and local electrical codes.

  4. When no “grounding means” exist within the wall box, the NEC® 2011, Article 404.9 allows a switch without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the switch and use an ap pro pri ate wallplate such as Claro or Satin Colors series wallplates by Lutron.

  5. Protect the switch from dust and dirt when painting or spackling the wall.

  6. This switch is not compatible with standard 3-way or 4-way switches. Use only with Lutron companion switches listed above.

  7. In any 3-way / 4-way circuit use only one switch with up to 4 companion switches.

  8. The maximum wire length between the switch and the farthest companion switch is 150 ft (45 m).

  9. Operate between 32 °F and 104 °F (0 °C and 40 °C).

  10. It is normal for the switches to feel warm to the touch during operation.

  11. Clean the switch with a soft damp cloth only. Do not use any chemical cleaners.
    For disinfecting, please refer to App Note #758 (048758), “Cleaning Recommendations for Lutron Products” at www.lutron.com.

  12. For indoor use only.

Determine wiring configuration

Fully wrap the wires around the screw and tighten (A), or strip insulated wires to 1/2 in (13 mm) and insert into the push-in terminals (B). Solid copper wire only.

OR

For lights switched from two locations:
NOTE: Only one switch can be used per circuit.

IMPORTANT:
Tag or mark the common wire on both existing devices. This is usually connected toa darker (or different) colored screw than the others. This does not include the ground screw.

NOTE : Switch MUST be on the load side.

NOTE: Switch must be wired on the load side. Connect Neutral to the switch. Up to four companion switches may be used.
For additional wiring assistance go to www.lutron.com/wiringwizard

NOTE: DO NOT install a switch on the line side.

For lights switched from three or more locations:

NOTE: Only one switch can be used per circuit.

NOTE: Switch must be wired on the load side. Neutral has been excluded from this diagram for clarity. Connect Neutral to the switch.
Up to four companion switches may be used. For additional wiring, assistance go to www.lutron.com/wiringwizard

Companion Switch

Companion Switch

Switch

Mount all devices using the provided screws and attach a wallplate

Turn power ON at circuit breaker

FCC / IC / IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radiofrequency exposure limits.
This Class B digital apparatus complies with Canadian ICES-003.

www.lutron.com/support
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
For FCC/IC information:
Please visit:www.lutron.com/fcc-ic
Lutron, Claro, and Satin Colors are trademarks or registered trademarks of
Lutron Electronics Co., Inc. in the US and/or other countries.
All product names, logos, and brands are the property of their
respective owners.
©2021 Lutron Electronics Co., Inc.

Documents / Resources

| LUTRON RRD-6CL-WH 120-VOLT AC AT 50/60-HZ Dimmer Switch [pdf] Instruction Manual
0135, JPZ0135, RRD-6CL-WH, 120-VOLT AC AT 50 60-HZ Dimmer Switch, RRD-6CL-WH 120-VOLT AC AT 50 60-HZ Dimmer Switch
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals