Extron PVT Series Pole Vault Twisted Pair Input Wallplates User Guide
- June 17, 2024
- Extron
Table of Contents
User Guide
PoleVault® Wallplates
PVT Series
PoleVault Twisted Pair Input Wallplates
(Decora® and AAP models)
PVT Series Pole Vault Twisted Pair Input Wallplates
PVT CV D, PVT RGB D Plus, PVT RGB
D
PVT CV AAP, and PVT RGB AAP
Precautions
Safety Instructions
This symbol is intended to alert the user of important operating and
maintenance (servicing) instructions in the literature provided with the
equipment.
This symbol is intended to alert the user of the presence of uninsulated
dangerous voltage within the product’s enclosure that may present a risk of
electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on
the equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Warning
Power sources • This equipment should be operated only from the power
source indicated on the product. This equipment is intended to be used with a
main power system with a grounded (neutral) conductor.
The third (grounding) pin is a safety feature, do not attempt to bypass or
disable it.
Power disconnection • To remove power from the equipment safely, remove
all power cords from the rear of the equipment, or the desktop power module
(if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not
likely to be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are
no user-serviceable parts inside.
To prevent the risk of shock, do not attempt to service this equipment
yourself because opening or removing covers may expose you to dangerous
voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the
enclosure, these are provided to prevent overheating of sensitive components
inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is
incorrectly replaced. Replace it only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
The Class A limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction
guide, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the
interference at his own expense.
NOTE: This unit was tested with shielded cables on the peripheral
devices. Shielded cables must be used with the unit to ensure compliance with
FCC emissions limits.
Conventions Used in this Guide
In this user guide, the following are used:
WARNING: A warning warns of things or actions that might cause injury,
death, or other severe consequences.
CAUTION: A caution indicates a potential hazard to equipment or data.
NOTE: A note draws attention to important information.
Copyright
© 2012 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective
owners.
Introduction
The section discusses basic information as an introduction to the PVT Series of twisted pair AV input wallplates.
About the PVT Input Wallplates
The Extron PVT Series PoleVault® Twisted Pair Input Wallplates (Decora® and
Architectural Adapter Plates [AAP] models) described in this guide are a
series of five cost effective twisted pair transmitters. These transmitters
work exclusively with PoleVault (PVS) switchers, which are twisted pair
switchers with a built in power amplifier.
PVT input wallplates are part of a system for distribution of composite video
and stereo audio, or high resolution video (RGB) and stereo audio, over:
- Extron Enhanced Skew-Free™ A/V UTP cable
- CAT 5e, or 6 shielded twisted pair (STP) cable
- unshielded twisted pair (UTP) cable
- foil shielded twisted pair (FTP) cable
All PVT wallplates are remotely powered via the twisted pair cable when
connected to the PoleVault switcher.
NOTES: PVT series of input wallplates are compatible ONLY with PVS
(PoleVault) switchers.
For PVS switcher installation and operation information, refer to the guide
supplied with the device.
Transmission distance
The maximum distance is determined by the frequency and resolution of the
signal that is input to the transmitter. However, all PVT models are capable
of transmitting signals to the PVS switcher if it is located not more than 125
feet away. The optimum distance is between 50 and 75 feet.
The PVT Decora and AAP models can be mounted in UL standard wall boxes with
Decorastyle face plates or in AAP openings in wall or device face plates. The
model types are as follows:
PVT CV D, PVT CV AAP — Transmit composite video and stereo audio.
PVT RGB D, PVT RGB D Plus, PVT RGB AAP — Transmit computer (RGB) video
and stereo audio.
See the “About the PVT …” sections in this chapter for details.
About the PVT CV D
The PVT CV D is a wall or furniture mountable wall plate that fits any single
opening Decora style wall plate. It can transmit composite video and stereo
audio to any PoleVault switcher.
In addition, a 2-pole IR pass-through provides control connection for IR
devices.
Figure 1. PVT CV D face and rear panels
About the PVT CV AAP
The PVT CV AAP fits a standard double space AAP opening and can transmit
composite video and stereo audio to the PVS switcher.
Figure 2.
PVT CV AAP face and rear panels
About the PVT RGB D (EDID)
The PVT RGB D (EDID) is a wall or furniture mountable model that fits any
single opening Decora style wall plate. It can transmit computer (RGB) video
and stereo audio to the PVS switcher, and has an IR pass-though port to a
provide control connection for DVD/VCR players, tuners, switchers, or other IR
controllable devices.
Figure 3. PVT RGB D (EDID) face and rear panels
NOTE: For all PVT RGB Decora and AAP models, two cable runs are required to carry the video and audio signals to the PVS switcher.
About the PVT RGB D Plus (EDID)
The PVT RGB D Plus (EDID) is a wall or furniture mountable model that fits
any single opening Decora style wall plate. It can transmit computer (RGB)
video and stereo audio to the switcher with a local monitor output and audio
output. In addition, a 2-pole IR passthrough provides control connection for
IR devices.
Figure 4. PVT RGB D Plus (EDID) face and rear panels
About the PVT RGB AAP (EDID)
The PVT RGB AAP fits a standard double height AAP opening in a wall plate or a
device’s front or secondary panel. It can transmit computer (RGB) video and
stereo audio to the PVS switcher. In addition, a 2-pole IR pass-through
provides control connection for IR devices.
Figure 5. PVT RGB AAP face and rear panels
Figure 6. Typical PVT series system application using PVT Decora and AAP transmitters with the PVS 305SA and other Extron device.
Installation
The section discusses the method of installation, cabling, and using EDID Minder of the PVT series wallplates.
UL Safety Requirements
The Underwriters Laboratories (UL) requirements listed below pertain to the
safe installation and operation of these devices.
Important safety instructions
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturers instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments or accessories specified by the manufacturer.
- Use only with the stand, tripod, bracket, or table specified by the manufacturer, or soldwith the apparatus.
- Unplug this apparatus during lightning storms or when unused for long periods of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way. Examples of this could be if the power-supply cord or plug is damaged, or if liquid has been spilled onto, or objects have fallen into the apparatus. Also if the apparatus has been exposed to rain or moisture, or does not operate normally, or has been dropped.
Installing the PVT CV and PVT RGB Decora models
The PVT CV and PVT RGB Decora models can be installed into a wall using either
the supplied mud ring or a UL approved one-gang electrical wall box, and
finished with a Decora wall plate cover (supplied).
The installation must conform to national and local electrical codes and to
the wall plate size requirements.
The following Underwriters Laboratories (UL) requirements pertain to the
installation of the PVT input wallplates into a wall or furniture.
- These units are not to be connected to a centralized DC power source or used beyond their rated voltage range.
- These units must be installed in UL listed junction boxes.
- These units must be installed with conduit in accordance with National Electrical and Buildong Codes
To Install into a Mud-ring
-
Using the mud ring as a guide, mark the edges and cut out the material within the marked area.
-
Insert the mud ring into the opening, rotate the arms, and secure with the supplied screws.
-
Run the CAT 5 cables from the PoleVault switcher location, going behind the wall and to the PVT location, then thread the cables through the mud ring.
NOTE: Two cables (A and B) are needed for RGB signals. One cable is used with CV models. Figure 7. Installing the mud ring -
Connect the switcher cables to the rear of the PVT wall plate. See “Rear Panel Features”, page 11, for connector wiring details.
-
Connect input devices (see “Front Panel Features”, page 9, for connector details), restore the power supply, and test the wall plate. Make any cabling adjustments before final installation, as the cables will be inaccessible afterwards.
To Install into a Wall Box
Choose a location that allows cable runs without interference. Allow enough
depth for both the wall box and the cables. The box should be at least 2.5
inches (6.4 cm) deep to accommodate the connectors and cables. Install the
cables into the wall, furniture, or conduits before installing the wall plate.
Follow the steps below
-
Feed cables for the output devices through the opening and through the wall box punch-out holes, securing them with cable clamps to provide strain relief.
-
Trim back and/or insulate exposed cable shields with heat shrink to reduce the chance of short circuits.
To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp.
Both braided and foil shields should be connected to an equipment ground at the other end of the cable. -
Connect the PoleVault switcher cables to the rear of the PVT wall plate. See “Rear Panel Features” on page 11 for connector wiring details.
-
Connect input devices (see “Front Panel Features” on page 9 for connector details), restore the power supply, and test the wall plate. Make any cabling adjustments before final installation, as the cables are inaccessible afterwards.
Installing the PVT CV and PVT RGB AAP models
The PVT CV AAP and PVT RGB AAP must be attached to a device faceplate or AAP
wall plate and cabled before the device or wall plate is tested and installed
in a wall or furniture.
-
Before attaching any cables, insert the AAP standoffs through the holes in the faceplate or AAP wall plate.
-
Using the supplied #4-40 nuts and captive washers, secure the AAP to the faceplate or wall plate. Figure 8. Mounting the PVT RGB AAP
-
Repeat steps 1 and 2 to mount any other AAPs. Cover any openings in the faceplate with blank plates (provided with the AAP faceplate).
-
Be sure to include the AAP connectors as part of the installation pretest before final installation of the faceplate.
-
For more detailed installation information, refer to the installation guide shipped with the device.
NOTE: The PVT input wall plate should be cabled and tested before it is finally installed into the wall or device face plate. The rear panel connections will be inaccessible after installation. See Rear Panel – Features on page 11. -
After testing and making any adjustments, turn off the power supply to the PoleVault switcher, and carefully secure the faceplate on the wall box device.
-
Reconnect the cables and turn on the power supply to the switcher. This powers up the AAP plates.
Connections and Settings
The section discusses the method of cabling and using EDID Minder for the PVT
series wallplates.
CAUTION: Do not connect these devices to a computer data or
telecommunications network.
Front Panel Features
The front panel features are the same within these groups:
- PVT CV D and PVT CV AAP, and
- PVT RGB D, PVT RGB D Plus, and PVT RGB AAP:
Figure 9. PVT series front panel features
- Dual color power LED (all models) — This LED lights red when power only (no signal) is applied to the PVT, and green when power and signal are both present.
- Audio (left and right) input (CV D and CV AAP models) — For unbalanced left and right audio input, plug male RCA audio plugs into these two female RCA jacks (white = left, red = right). Figure 10. RCA audio connectors
- Composite video input (CV D and CV AAP models) — To input a composite video signal from a suitable source, insert a male RCA plug into this yellow female RCA jack.
- Audio input (RGB D and RGB AAP models) — Plug a 3.5 mm stereo audio plug into this jack for unbalanced audio input. Wire the plug as shown in figure 13. Figure 11. 3.5 mm stereo audio plug
- RGB video input (RGB D and RGB AAP models) — Connect a computer video source to this 15-pin HD connector for high resolution RGB video input.
- Local monitor output (RGB D Plus model) — Connect a monitor to this 15-pin HD to view the output locally.
- IR pass-through (All models except PVT CV AAP) — Connect to this 2-pole IR pass-through connector to provide control via IR devices
- Audio pass-through (RGB D Plus model) — Plug a local audio device into this 3.5 mm stereo jack for audio pass-through. Wire the plug as shown in figure 13.
Rear Panel
Output cabling
The PVT cable termination method is specific for PVT input wall plates used
with the PoleVault switcher. The supplied cables are terminated to TIA/EIA T
568A standard.
NOTE: When terminating CAT 5e, CAT 6, and Skew-Free A/V UTP cables with
RJ-45 connectors, it must comply with the TIA/EIA T 568A or T 568B wiring
standards, with the same standard used at both ends.
DO NOT connect to an MTP system.
RJ-45 Connector
Pin | 568A Wire Color | Wire Color 568B |
---|---|---|
1 | White-green | White-orange |
2 | Green | Orange |
3 | White-orange | White-green |
4 | Blue | Blue |
5 | White-blue | White-blue |
6 | Orange | Green |
7 | White-brown | White-brown |
8 | Brown | Brown |
Rear Panel — Features
All models have the output connectors on the rear panel.
Figure 12. PVT CV models rear panel features
-
Composite video output (PVT CV models) — For composite video output, using CAT 5e or 6 UTP cable, connect this RJ-45 female video output port to one of the two composite video RJ-45 input connectors (labelled 3 and 4 video), on the rear panel of the PoleVault switcher. Figure 13. Connecting the PVT CV D to the PoleVault switcher
-
IR connector (2-pole) (PVT RGB D, PVT RGB AAP, PVT RGB D Plus models) — For IR pass-through control, wire this connector from the IR controller, with ground to “G” and signal to “S”). Figure 14. PVT RGB models rear panel features
-
a. RGB A output (PVT RGB models) — Using CAT 5e or 6 UTPcable, connect this RJ-45 female output port labelled “RGB A out” to one of the input ports labelled A (for example, 2A) on the PoleVault switcher.
b. RGB B output (PVT RGB models) — Using CAT 5e or 6 UTP cable, connect this RJ-45 female output port labelled “RGB A out” to one of the input ports labelled B (for example, 2B) on the PoleVault switcher.
NOTE: Cable A carries horizontal sync information and the red, green, and blue signals. Cable B primarily carries the audio signal, the vertical sync information, and 5 VDC to power the PVT transmitter. Figure 15. Connecting the PVT RGB D or PVT RGB D Plus to the PoleVault switcher -
Audio pass-through connector (PVT RGB D Plus models) — Connect an audio source to this 3-pole connector for audo pass through output. Connect the ground to “G”, right speaker to “R”, and left speaker to “L”.
-
EDID Minder 5-pole DIP switch — If the display refresh rate and resolution is known, set the EDID Minder 5-pole DIP switches according to the EDID table (see “EDID Minder” section, page 13 for details).
Alternatively, if the EDID Minder is used in Learn mode, set all the DIP switches to off.
EDID Minder
The PVT RGB D (EDID), PVT RGB D Plus (EDID), and PVT RGB AAP (EDID)
incorporates EDID Minder, which allows the transmitter to communicate the
appropriate EDID information to the source, ensuring correct video output
resolution.
The 5-pole EDID Minder settings DIP switch is located on the rear of the
wallplate. Once installed, these switch settings are only accessible by
removing the device from its installed location. The factory EDID setting
(default) is 1024×768@60 Hz (preset 2).
The EDID Minder has two modes; a Preset (Emulation) mode and a Learn mode.
- Preset Mode is available on all PVT RGB (EDID) models, and allows selection of pre-programed EDID rates, as shown in the table below.
- Learn Mode is available only on the PVT RGB D Plus model, and enables the displays specific EDID information to be recorded and emulated by the input wallplate.
To use the EDID Minder mode in Preset or Learn Mode, follow the instructions below
Using Preset mode
- If already installed, disconnect any sources and displays from the front panel and remove the wallplate from the wall.
- On the rear panel, set DIP switch 1 to 50 or 60 kHz as desired.
- Set DIP switches 2 – 5 accordingly to match the desired EDID rate (see table below).
- Connect the video source to the “Computer In” VGA connector and a local display device to the “Monitor Out” port. This setting is for 1024×768@60 Hz, preset 2 (factory default)
- Restart the video source and display devices. Verify the image, making any changes to the EDID settings as needed.
- When the image is correct, re-install the wallplate. Re-connect and restart the source and display devices.
Preset
Number| Switch setting| Resolution
---|---|---
2| 3| 4| 5
0| OFF| OFF| OFF| OFF| Learn Mode (PVT RGB D Plus only)
1| OFF| OFF| OFF| ON| 800×600
2| OFF| OFF| ON| OFF| 1024×768 (default)
3| OFF| OFF| ON| ON| 1280×720
4| OFF| ON| OFF| OFF| 1280×768
5| OFF| ON| OFF| ON| 1280×800
6| OFF| ON| ON| OFF| 1280×1024
7| OFF| ON| ON| ON| 1360×768
8| ON| OFF| OFF| OFF| 1366×768
9| ON| OFF| OFF| ON| 1400×1050
A| ON| OFF| ON| OFF| 1440×900
B| ON| OFF| ON| ON| 1600×1200
C| ON| ON| OFF| OFF| 1680×1050
D| ON| ON| OFF| ON| 1920×1080
E| ON| ON| ON| OFF| 1920×1200
F| ON| ON| ON| ON| N/A
Using Learn mode (available on PVT RGB D Plus only)
- Disconnect any sources from the front panel and remove the wallplate from the wall.
- On the rear panel, set all the DIP switches to off (down).
- Temporarily connect the main display device (the projector) to the “Monitor Out” port.
- On the front panel, the learn LED is lit solid green. Press and release the Learn button.
- The LED flashes red when in “learning” mode, then returns to solid green when complete.
- Re-install the wallplate and reconnect the source device. Connect a local display device to the “Monitor Out” port as needed.
- Reconnect the projector to the PoleVault switcher. Restart the source and display devices
Final installation
After testing and making any adjustments, do the following:
-
Turn off the power supply to the PoleVault switcher.
NOTE: The power to the transmitter is supplied by the PoleVault switcher. -
Mount the transmitter into the box or mud ring, and attach the supplied Decora faceplate to the transmitter, as shown below. Figure 16. Mounting the PVT RGB D Plus (EDID)
-
Reconnect the cables and turn on the power supply to the switcher This powers up the wall plates.
Reference Material
Specifications
PVT Series
NOTE: These transmitters are compatible only with an Extron PoleVault®
Switcher (PVS). They are not compatible with other models of twisted pair
receivers.
Video — RGB
Gain ……………………………………….. Unity
Video input and loop-through — RGB
Number/signal type
PVT RGB D Plus models ………… 1 VGA-UXGA RGBHV, RGBS 1 buffered RGBHV, RGBS local
monitor loop-through
All other models …………………. 1 VGA-UXGA RGBHV, RGBS
Connectors
PVT RGB D Plus …………………… 2 female 15-pin HD (1 for input, 1 for loop-through)
All other models …………………. 1 female 15-pin HD
Nominal level …………………………… 0.7 Vp-p for RGB
Minimum/maximum levels ………….. Analog: 0.3 V to 1.5 Vp-p with no offset
Impedance ………………………………. 75 ohms
Horizontal frequency …………………. 15 kHz to 130 kHz
Vertical frequency ……………………… 30 Hz to 150 Hz
Return loss ………………………………. <-30 dB @ 5 MHz
DC offset (max. allowable) …………. 250 mV
Video output — RGB
Number/signal type …………………… 2 analog proprietary signals
Connectors
All models …………………………. 2 female RJ-45
Sync — RGB
Input type ……………………………….. RGBHV, RGBS
Input level ……………………………….. 3.5 V to 5.5 Vp-p, unterminated
Input impedance ………………………. 510 ohms
Max. input voltage ……………………. 5.5 Vp-p
Video — composite video
Gain ……………………………………….. Unity
Differential phase error ………………. <1.0° at 3.58 MHz and 4.43 MHz
Differential gain error ………………… <1.0% at 3.58 MHz and 4.43 MHz
Video input — composite video
Number/signal type …………………… 1 composite video
Connectors ……………………………… 1 female RCA
Nominal level …………………………… 1 Vp-p for composite video
Minimum/maximum levels ………….. Analog: 0.3 V to 1.5 Vp-p with no offset
Impedance ………………………………. 75 ohms
Return loss ………………………………. <-30 dB @ 10 MHz
DC offset (max. allowable) …………. 100 mV
Video output — composite video
Number/signal type …………………… 1 analog proprietary signal
Connectors
All models …………………………. 1 female RJ-45
Sync — composite video
Standards ………………………………… NTSC 3.58, NTSC 4.43, PAL, SECAM
Audio input
Number/signal type
PVT RGB D Plus …………………… 2 stereo, unbalanced: 1 input, 1 pass-through
All other models …………………. 1 stereo, unbalanced
Connectors
All RGB models …………………… (1) 3.5 mm mini audio jack (tip, ring, sleeve)
All CV models …………………….. 1 pair female RCA
Impedance ………………………………. >10k ohms unbalanced, AC coupled
Nominal level …………………………… -10 dBV (316 mVrms)
Maximum level …………………………. +11 dBu, (unbalanced) at 1% THD+N
NOTE: 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
Audio output to a PoleVault switcher (all models)
Number/signal type …………………… 1 analog proprietary signal
Connectors
All models …………………………. 1 female RJ-45
Audio output — pass-through, PVT RGB D Plus only
Number/signal type …………………… 1 stereo, unbalanced
Connector ……………………………….. (1) 3.5 mm mini audio jack (tip, ring, sleeve)
Control — IR port — PVT CV D, PVT RGB D Plus, PVT RGB D (EDID), PVT RGB AAP
(EDID)
Number and connectors …………….. 1 female 3.5 mm captive screw connector, 2
pole, for IR pass-through
General
Power …………………………………….. Supplied by a PoleVault twisted pair receiver/switcher
Power input requirements
PVT RGB D, PVT RGB AAP, PVT RGB D Plus 5.5 VDC, 0.15 A
PVT CV AAP, PVT CV D ………… 5.5 VDC, 0.11 A
Temperature/humidity ……………….. Storage: -40 to +158 °F (-40 to +70 °C) / 10% to
90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling …………………………………… Convection, no vents
Mounting
Rack mount
PVT CV AAP, PVT RGB AAP Yes, with optional faceplate
Furniture or wall mount
PVT CV D, PVT RGB D, PVT RGB D Plus Yes, with the included Decora® wall plate
PVT CV AAP, PVT RGB AAP Yes, with optional faceplates or AAP wall plates
Enclosure type
PVT CV D, PVT RGB D, PVT RGB D Plus Plastic
All other models …………………. Metal
Enclosure dimensions
PVT CV D, PVT RGB D and PVT RGB D Plus (including EDID models)
Faceplate ……………………… 2.6″ H x 1.3″ W x 0.2″ D (6.6 cm H x 3.3 cm W x 0.6 cm D)
(Fits the openings in a 1 gang Decora® plate.)
Device ………………………….. 2.7″ H x 1.7″ W x 1.6″ D
(6.9 cm H x 4.3 cm W x 4.1 cm D)
(Depth excludes connectors, height excludes mounting tabs.)
PVT RGB AAP (EDID)
Faceplate ……………………… 1.4″ H x 3.5″ W x 0.1″ D (3.5 cm H x 8.9 cm W x 0.3 cm D)
(double space AAP plate)
Device ………………………….. 1.4″ H x 2.7″ W x 1.6″ D
(3.6 cm H x 6.9 cm W x 4.1 cm D)
(Depth excludes connectors, height excludes mounting tabs.)
Product weight
All models …………………………. 0.2 lbs (0.1 kg)
Shipping weight ……………………….. 2 lbs (1 kg)
Vibration …………………………………. ISTA 1A in carton (International Safe Transit
Association)
Regulatory compliance
Safety ……………………………….. CE, c-UL, UL
EMI/EMC …………………………… CE, C-tick, FCC Class A, ICES, VCCI
MTBF ……………………………………… 30,000 hours
Warranty …………………………………. 3 years parts and labor
NOTES: All nominal levels are at ±10%.
Specifications are subject to change without notice.
Part Numbers and Accessories
PoleVault AV Input Plate Part Numbers
Description | Part Number |
---|---|
PVT CV D | 60-819-33 |
PVT RGB D | 60-1066-03 |
PVT RGB D PLUS | 60-1065-03 |
PVT CV AAP, black, white | 70-579-12,13 |
PVT RGB AAP, black, white | 70-722-02,03 |
Included Parts
Items marked * are for PVT CV D, PVT RGB D, and PVT RGB D Plus models only.
Description | Quantity |
---|---|
Single gang Decora®wall plate* | 1 |
Single gang mudring* | 1 |
Captive screw connector, 2-pole | 1 |
6-32, 7/8L, mounting screws* | 2 |
Tie Wrap | 1 |
Setup guide | 1 |
Optional Accessories
Description | Part Number |
---|---|
CAT 5e cable, 35′, plenum | 26-637-35 |
CAT 5e cable, 50′, plenum | 26-637-50 |
CAT 5e cable, 75′, plenum | 26-637-75 |
CAT 5e cable, 100′, plenum | 26-637-100 |
AAP Optional Parts
These items can be ordered separately and for AAP models only:
Description | Part Number |
---|---|
AAP 100 panel, black, white | 60-593-02, 03 |
AAP 102 panel, black, white | 60-300-02, 03 |
AAP 104 panel, black, white | 60-301-02, 03 |
AAP 201 panel, ½ rack width, 1U, black | 60-302-02 |
AAP 301 panel, 1 rack width, 1U, black | 60-632-02 |
AAP 302 panel, 1 rack width, 2U, black | 60-633-02 |
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, and Central America:
Extron Electronics 1001 East Ball Road Anaheim, CA 92805 U.S.A.| Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan
---|---
Europe and Africa:
Extron Europe
Hanzeboulevard 10 3825 PH Amersfoort The Netherlands| China:
Extron China
686 Ronghua Road Songjiang District Shanghai 201611 China
Asia:
Extron Asia
135 Joo Seng Road, #04-01 PM Industrial Bldg. Singapore 368363 Singapore|
Middle East:
Extron Middle East
Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai
This Limited Warranty does not apply if the fault has been caused by misuse,
improper handling care, electrical or mechanical abuse, abnormal operating
conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an
Application Engineer to receive an RA (Return Authorization) number. This will
begin the repair process.
USA: 714.491.1500 or 800.633.9876
Asia: 65.6383.4400
Europe: 31.33.453.4040
Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured,
you assume the risk of loss or damage during shipment. Returned units must
include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied
with respect to the product and its quality, performance, merchantability, or
fitness for any particular use. In no event will Extron Electronics be liable
for direct, indirect, or consequential damages resulting from any defect in
this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and
that some provisions of this warranty may not apply to you.
Extron Headquarters
+1.800.633.9876
(Inside USA/Canada Only)
Extron USA – West
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA – East
+1.919.850.1000
+1.919.850.1001 FAX| Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX| Extron Asia
+800.7339.8766
(Inside Asia Only)
+65.6383.4400
+65.6383.4664 FAX| Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
---|---|---|---
Extron China
+4000.398766
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX| Extron Middle East
+971.4.2991800
+971.4.2991880 FAX| Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX| Extron India
1800.3070.3777
Inside India Only
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2012 Extron Electronics All rights reserved.
www.extron.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>