Please read before installing.
Dimmer
120 V~ 50 / 60 Hz
Find the right LED
Turn power OFF at circuit breaker
WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off power at the circuit breaker
or fuse before installing.
IMPORTANT
- CAUTION: Use only with permanently installed fixtures with dimmable screw-in LED, dimmable self-ballasted compact fluorescent, halogen, or incandescent lamps. Use only to control the primary side of permanently installed transformer supplied low-voltage lighting or in combination with incandescent lamps. To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles, fluorescent lighting fixtures, non-ballasted or externally ballasted compact fluorescent lamps, motor-operated appliances or transformer supplied appliances.
- Neutral is required for all load types.
- Install in accordance with all national and local electrical codes.
- When no “grounding means” exists within the wall box, the NEC® 2011, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the dimmer and use an ap pro pri ate wallplate such as Claro or Satin Colors series wallplates by Lutron.
- Protect the dimmer from dust and dirt when painting or spackling the wall.
- This dimmer is not compatible with standard 3-way or 4-way switches. Use only with Lutron companion dimmers listed above.
- In any 3-way / 4-way circuit use only one dimmer with up to 4 companion dimmers.
- The maximum wire length between the dimmer and the farthest companion dimmer is 150 ft (45 m).
- Operate between 32 °F and 104 °F (0 °C and 40 °C).
- It is normal for the dimmers to feel warm to the touch during operation.
- Clean the dimmer with a soft damp cloth only. Do not use any chemical cleaners. For disinfecting, please refer to App Note #758 (048758), “Cleaning Recommendations for Lutron Products” at www.lutron.com.
- For indoor use only.
Determine wiring configuration
Fully wrap the wires around the screw and tighten (A), or strip insulated wires to 1/2 in (13 mm) and insert them into the push-in terminals (B). Solid copper wire only.
For lights controlled from two locations:
NOTE: Dimmer must be wired on the load side. Connect Neutral to the dimmer. Up to four companion dimmers may be used. For additional wiring, assistance go to www.lutron.com/wiringwizard
NOTE: Only one dimmer can be used per circuit.
NOTE: Dimmer MUST be on the load side.
NOTE: DO NOT install dimmer on the line side.
** For more information please go to www.lutron.com/wiringwizard
For lights controlled from three or more locations:
NOTE: Dimmer must be wired on the load side. Connect Neutral to the dimmer. Up to four companion dimmers may be used. For additional wiring, assistance go to www.lutron.com/wiringwizard
NOTE: Only one dimmer can be used per circuit.TE: Only one dimmer can be used per circuit.
Mount all devices using the provided screws and attach a wallplate
Turn power ON at circuit breaker
FCC / IC / IFT Information
This device complies with part 15 of the FCC Rules and Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may
cause undesired operation. Modifications not expressly approved by Lutron
Electronics Co., Inc. could void the user’s authority to operate this
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/ISED radiation exposure limits set forth for
an uncontrolled environment. The user should avoid prolonged exposure within
7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency
exposure limits.
This Class B digital apparatus complies with Canadian ICES-003.
Help
Use our mobile-friendly self-paced installation tool:
www.lutron.com/wiringwizard
Find more product information:
www.lutron.com/support
– Videos
– Frequently Asked Questions
– Online Chat (8 am – 5 pm EST)
Call us:
U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico +1.888.235.2910
Others +1.610.282.3800
www.lutron.com/support
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
For FCC/IC information:
Please visit: www.lutron.com/fcc-ic
Lutron, Claro, and Satin Colors are trademarks or registered trademarks of
Lutron Electronics Co., Inc. in the US and/or other countries.
All product names, logos, and brands are the property of their
respective owners.
©2021 Lutron Electronics Co., Inc.
References
- LED Compatibility Tool | Lutron
- lutron.com/fcc-ic
- Lutron Support Center | Lutron
- How to Install a Dimmer Switch | Dimmer Switch Wiring | Lutron Web Tools
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>