immax 07505L Neo Smart Keypad User Manual

June 5, 2024
immax

07505L Neo Smart Keypad
User Manual
immax 07505L Neo Smart Keypad

Manufacturer and importer:
IMMAX, Pohoří 703, 742 85 Vřesina, EU | www.immaxneo.cz | www.immaxneo.com
Made in P.R.C.

PACKAGE CONTENTS

  • 1 x Zigbee keyboard
  • 3 x AAA 1.5 V batteries
  • 1 x User’s Guide
  • 4 x screws

DESCRIPTION

immax 07505L Neo Smart Keypad - figure 1

SPECIFICATIONS

Power supply: DC 4.5 V (AAA 1.5 V battery x3)
Zigbee communication protocol: 3.0
Frequency: 2,400-2,483 GHz
Antenna: built-in PCB antenna
Wireless range: 30 m direct visibility, 10 m in a built-up area
Static current: max. 100 uA
Operating current: max. 30 mA
Material: ABS plastic
Operating temperature: -0 ° C to + 55 ° C
Operating humidity: maximum 80% (no condensation)
Degree of protection: IP20
Dimensions: 135x90x15mm

BASIC INFORMATION

System power on: User/administrator code + Out of mode button
System deactivation: User/administrator code + Deactivate button
Home mode: User/administrator code + Home mode button
Emergency call: User/administrator code + SOS button
Default administrator code: 123456
Default user code: 1234

PAIRING WITH THE IMMAX NEO PRO SMART GATEWAY

Download the Immax NEO PRO app from Google Play or the Apple store.
Set your Immax NEO PRO gateway to “Add sub-device”
Switch the keypad to setting mode: enter the administrator code and confirm #. The LED will light up.
Enter the Zigbee network configuration code on the keypad: 4210 #, the LED will start flashing. If an audible signal sounds, the keypad is successfully paired with the smart gateway.

SYSTEM SETTINGS

Setting mode: Admin code + #
To exit the setting mode: briefly press the Deactivate button

To turn on / off the beep when a button is pressed:
Power on: 3210 #
Power off: 3211 #

Enable/disable security on delay:
Power on: 3310 #
Power off: 3311 #

Delay time setting: 34 + delay time (0 – 180) + #

Enable/disable SOS Quick Launch:
Power on: 3510 #
Power off: 3511 #

Enable/disable Quick Off mode Off:
Power on: 3610 #
Power off: 3611 #

Activating / deactivating the quick deactivation mode Deactivation:
Power on: 3710 #
Power off: 3711 #

User code change 1: 38 + 4-digit numeric code + #
User code change 2: 50 + 4-digit numeric code + #
User code change 3: 51 + 4-digit numeric code + #
Change user code 4:52 + 4-digit numeric code + #
User code change 5: 53 + 4-digit numeric code + #
User code change 6:54 + 4-digit numeric code + #
User code change 7:55 + 4-digit numeric code + #
User code change 8: 56 + 4-digit numeric code + #
User code change 9:57 + 4-digit numeric code + #
User code change 10: 58 + 4-digit numeric code + #

Administrator code change: 39 + 6-digit numeric code + #
Enable/disable pairing mode to ZigBee network:
Power on: 4210 #
Off: 4211 #
Keyboard reset: 987654321 + #
Note: If you turn on the option to quickly start the SOS mode, Outside,
In deactivation, it is not necessary to enter the user code.
You can also set all these functions in the Immax NEO PRO application.

INSTALLATION

Before installing the keyboard on the wall, make sure that there is good signal coverage from the Zigbee gate (Immax NEO PRO) at the installation site.
Step 1: Unscrew the captive screw and remove the keyboard back cover
Step 2: Screw the keyboard back cover to the selected location
Step 3: Put the keyboard back on the back cover and secure it with the locking screw.

IMAX NEO PRO APPLICATION
Download the Immax NEO PRO app from Google Play or the Apple store.

immax 07505L Neo Smart Keypad - qrhttps://smartapp.tuya.com/immaxneosmartimmax 07505L Neo Smart
Keypad - ce

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals