PDI-179AV-B Standard Wall Arm Mount Installation Guide

June 5, 2024
PDi

PDI-179AV-B Standard Wall Arm Mount
Installation Guide

SAFETY INFORMATION

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

Overhead Falling Hazard
Warning: To prevent injury, this apparatus must be securely attached to the wall in accordance with the installation instructions. The monitor can pose a striking hazard
when mounted at an elevated position. Use only PDi mounting brackets, support arms, and appropriate hardware to assure the monitor will not fall from the mounted position.

Rain and Moisture
WARNING: To avoid the hazards of fire or electrical shock, DO NOT expose this apparatus to rain or moisture.

Oxygen Environment
WARNING: Do not use any oxygen tent or oxygen chamber. Such use may cause a fire hazard.

Note to Cable TV Installer
This reminder is provided to call the cable TV systems installer’s attention to Article 820-40 of the National Electrical Code. The code provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of the cable entry as practical. Canadian installations shall be properly grounded in accordance with the Canadian Electrical Code, Part 1.

PDI 179AV B Standard Wall Arm Mount - Cable TV
Installer

PDI 179AV B Standard Wall Arm Mount - icon
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

Maintenance and Servicing
This unit does not require periodic maintenance other than cleaning.
Cleaning and Disinfection
Clean the exterior of this wall mount bracket by removing dust with a lint- free cloth. The suggested cleaning agent is 5% Bleach and Water solution. CAUTION: To avoid damage to the surface of the wall mount bracket, do not use abrasive or chemical cleaning agents. Spot test a new disinfectant by test cleaning a non-obvious small spot on the wall bracket surface. Allow the disinfectant to soak per its instructions and then wipe clean. Do not use the disinfectant if the wall bracket’s surfaces show any sign of discoloration or softening.
Product Modification
Do not attempt to modify this product in any way without written authorization. Unauthorized modification could void the user’s authority to operate the product.
Copyright, Trademarks
© 2017 PDi Communication Systems, Inc. All rights reserved. Product logos, brands, and other trademarks displayed within PDi’s products are the property of their respective trademark holders, who are not affiliated with, endorsing, or sponsoring PDi Communication Systems Inc. or our products.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES. READ AND FOLLOW THE SAFETY
INSTRUCTIONS BEFORE ATTEMPTING THIS INSTALLATION.

  1. Read these Instructions – All the safety and operating instructions should be read before the product is operated.
  2. Keep these Instructions – The safety and operating instructions should be retained for future reference.
  3. Heed all Warnings – All warnings on the product and in the operating instructions should be adhered to.
  4. Follow all Instructions – All warnings on the product and in the operating instructions should be followed.
  5. Do not use this apparatus near water – for example, near a bathtub, washbowl, in a wet basement; or a swimming pool; and the like.
  6. Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. The openings should never be blocked by placing the product on a bed, sofa, rug, or another similar surface.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. DO NOT defeat the safety purpose of the polarized or grounding-type plug. This product is equipped with a three-wire grounding-type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the product.
  11. Attachments – Only use attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over .
  13. Unplug this apparatus during lightning storms when it is left unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  15. Power Sources – This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions.
  16. Oxygen Environment – Do not use in an oxygen tent or oxygen chamber. Such use may cause a fire hazard.
  17. Lightning – For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent damage to the product due to lightning and power-line surges.
  18. Servicing – Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

SCOPE:
To install a PDI-179AV or PDI-179AV5, with or without a backer plate. Contact PDI for a complete list of compatible arm models that can be used with this Wall Mount Bracket.
NOTES:
If you have questions, contact PDi ProServices at Ph: 1-800-628-9870, email: t1service@pdiarm.com.
For more information on how to install PDI Backer Plates reference document PD196-094, included with the shipment of Backer Plates.

Disclaimer
The author and publisher have used their best efforts in preparing this manual. PDi Communication Systems, Inc. makes no representation or warranties with respect to the accuracy or completeness of the contents of this manual and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose and shall in no event be liable for any loss of profit or any other damages. The information contained herein is believed accurate, but is not warranted, and is subject to change without notice or obligation.

MOUNTING GUIDELINES

  1. LOCATION – Make certain that the chosen Wall Mount Bracket location is near enough to the cable connection interface so that it can be connected. The cables can also enter from behind the wall bracket. Position the Wall Mount Bracket at a mounting height of 47±2 inches. See Figure 1.
    PDI 179AV B Standard Wall Arm Mount - MOUNTING
GUIDELINES Figure 1

  2. WALL STRENGTH – These wall bracket mounting instructions cover the most desirable mounting method, backing plate mounting, as well as other, recommended mounting methods depending on wall construction.
    IN ALL CASES the wall construction must be able to support a minimum compression loading of 350 PSI applied perpendicular to the mounting locations.
    a) Minimum installation Requirements
    • Wall construction:
    o Wall studs are to be wood, with a 2×4 minimum size, and be spaced 16″ on centers.
    o Stud orientation shall be with the “4” inch dimension perpendicular to the surface plasterboard.
    o The surface plasterboard shall have a maximum thickness of 5/8″.
    • Installation of PDi backer plate:
    o Attaching fasteners will be 1/4″ lag for the wood studs that provide a minimum of 2-1/2″ engagement with the wood studs.
    b) PDi RECOMMENDED INSTALLATION METHOD
    • At the time of this printing, the following configuration is the preferred method for installing PDi’s Wall Mount Bracket.
    • Wall construction:
    o Wall studs are galvanized steel, 25 gauge minimum, with a 2×4 minimum size, and be spaced 16″ on centers.
    o Stud orientation shall be with the “4” inch dimension perpendicular to the surface plasterboard.
    o The surface plasterboard shall have a maximum thickness of 5/8″.
    • Installation of PDi backer plate:
    o Attaching fasteners will be 1/4″ diameter grade 5 (bolts or screws).
    o Captive solid bar toggles: TOGGLER brand Snaptoggle, HILTI, or equivalent (see Appendix).
    o Anchorage to two adjacent studs, two fasteners in each, is required.

  3. HARDWARE REQUIRMENTS – Use the following hardware for all wall bracket installations.
    a) All threaded rods, bolts, machine screws, and anchors will be ¼”-20UNC-2A thread, grade 5 or higher.
    b) Backer plate recommendations are below.
    c) All threaded rods will be finished off with the washer and cap covers, supplied with the wall bracket.
    d) Fastening anchors should be HILTI, Snaptoggle, or equivalent (see appendix).

  4. THE MAXIMUM COMBINED WEIGHT of the monitor and support arm system must be no more than 55 pounds.

INSTALLATION WITH TOGGLE ANCHORS & BACKER PLATE
Fastening anchors should be Snaptoggle, HILTI, or equivalent (see appendix).
Notes:
Instructions regarding the toggle anchors are for reference, review manufacturer installation instructions for the specific toggle anchors. If not using a PDi Backer Plate, arrange the toggle anchors using the hole pattern shown in Figure 7 below at the desired location on the wall.

  1. Drill a ½” (13mm) hole, in the center of the stud flange. Hold the metal channel flat alongside plastic straps and slide the channel through the hole. the Minimum clearance behind the wall is 1-7/8” (48mm). Fig. 2
    PDI 179AV B Standard Wall Arm Mount -BACKER PLATE 1

  2. Hold ends of straps between thumb and forefinger and pull toward you until the channel rests flush behind the wall. Slide plastic cap along with straps with another hand until the flange of the cap is flush with the wall. Fig. 3

  3. The toggle should be through the center of the steel edge flange. Fig. 4
    PDI 179AV B Standard Wall Arm Mount -BACKER PLATE 2

  4. Cut or snap straps at the wall by pushing side to side with the flange of the cap. Fig. 5

  5. Align mounting holes on the PDi backer plate with the toggle anchors and install mounting hardware as shown.

PDI 179AV B Standard Wall Arm Mount -BACKER PLATE 3

PDI 179AV B Standard Wall Arm Mount - ASSEMBLY

PDI-179AV5 Cable Clamp Installation:
PDI-179AV5 allows for use of any combination of cables.

  1. Install wall mount bracket to the wall, before making cable connections.
  2. Connect cables from the PDi arm to appropriate building cables. Wrench tighten coax connections.
  3. Clamp cables using PD203-125 & PD185-013.
  4. Insert cable connections and excess cable length behind the wall mount bracket and attached the cable clamp plates to the bottom of the wall bracket, and secure with supplied PDIPPHMS83231SS screws.

ELECTRICAL CONNECTIONS:

  1. Attach the coaxial cable from ARM to “F” fitting and wrench tighten to 15-20 in-lb.
  2. Connect CAT connection(s)

OTHER MOUNTING METHODS
There are other methods to mount a PDI-179AV or a PDI-179AV5, but the PREFERRED mounting is a backer plate system as described. The mounting method used must meet the requirements as described on page 3 of this document. The following mounting methods may be used if the previously listed precautions are adhered to.

1. SOLID CONSTRUCTION WALLS – Concrete, brick, some types of cement block, and cement expansion anchors can be used.
Proof tests of the anchors to the manufacturer’s specifications in tension should be performed on the wall before the installation of the expansion anchors in the mounting location.

It is the responsibility of the architect and/or structural engineer, in charge of the project, to sign and submit the necessary calculations that show the adequacy of the wall where the TV arm and mount will be installed. Drill four holes, which correspond to the mounting hole pattern, to the manufacturer’s specifications of the chosen mounting fastener. Install four HILTI, or equivalent, cement anchors per the manufacturer’s installation procedure. Position the wall bracket over the exposed mounting holes/studs. Thread bolt and washer through the bracket and into hole or nut and washers over studs. Tighten all bolts.

APPENDIX
KWIK BOLT 3 EXPANSION ANCHOR

Installation Information Strength Design

Setting Information Units Nominal anchor diameter
1/4 3/8
Effective min embedment IN 1-1/2
(mm) (38) (51)
Min hole depth IN 2
(mm) (51) (67)
Installation torque Ft-lb 4
(Nm) (5) (27)

Carbon Steel KB3 Strength Design

Design Information Units Nominal anchor diameter
1/4 3/8
Effective min. embedment IN 1-1/2
(mm) (38) (51)
Min. hole depth in concrete IN 2
(mm) (51) (67)
Pullout strength uncracked concrete Lb 1,575
(kN) (7.0)
Pullout strength concrete on metal deck Lb 1,750
(kN) (7.8) (10.0)
Installation torque Ft-lb 4
(Nm) (5) (27)

SNAPTOGGLE® HEAVY-DUTY HOLLOW-WALL ANCHORS

Anchor| UNC
thread| Drill dia.| ½” Drywall| 5/8”
Drywall| ½” w/ 25
gauge stud|
5/8” w/
25 gauge
stud| Concrete
block| ½” steel
plate| Stainless
in 3
---|---|---|---|---|---|---|---|---|---
BB| ¼”-20| ½”| 265| 356| 425| 464| 1,080| 1,288| 1,735

PDi Communication Systems, Inc. ▪ 40 Greenwood Ln ▪ Springboro, Ohio 45066 USA ▪ www.pdiarm.com and www.mymedTV.com ▪ Phone 800.628.9870

PDI 179AV B Standard Wall Arm Mount - icon 2

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PDi User Manuals

Related Manuals