Shenzhen Xingren Eucalyptus Networkco AS18 X2 Openear Waterproof Bone Conduction Headphones User Manual

June 4, 2024
Shenzhen Xingren Eucalyptus Networkco

Waterproof Bone Conduction Headphones

OPENEAR  AS18 X2

User Manual

How to Wear
What’s In the Box

OPENEAR  AS18  X2

Pouch X1                        Ear-plugs X1

Manual X1                       Charging Cable x1

Specifications

Model: OPENEAR  AS18  X2
Type: Bone Conduction Headphones
BT Version: 5.2
Connection: ≥10m/33feet
Battery: 180mAh
Play Time: ≥8h
Charging Time: ≈1.5h
Charging Voltage: DC 5V

Button Control

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
4

  1. charging port
  2. MFB
  3. Button +
  4. Button –
Power On/Off

Power On: press & hold the MFB for 3 sec, prompt: power on;
Power Off: press & hold the MFB for 3 sec, prompt: power off;

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
5 BT Connection

The headset enters BT mode automatically when power-on . Select “AS18 X2” in BT menu to connect, prompt: connected.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
6

Switch BT/MP3 mode

Under power-on state, double click the MFB to switch BT/MP3 mode.

Data Transfer
  1. Download the audio files (mp3,wav formats only) into your computer.
  2. Attach the headset to the USB charging cable.
  3. Connect the USB cable to a computer USB port.
  4. You could see a hard drive on your computer and open it.
  5. Drag-and-drop the files into the hard drive folder.
  6. Eject the hard drive after files transfer is complete.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
7

Play/Pause Music

Click once the MFB.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
8

Previous/Next Track

Previous Track: press and hold the button – for 3 sec.
Next Track: press and hold the button + for 3 sec.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
9

Volume Up/Down

Volume Up: click once the button +.
Volume Down: click once the button -.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
10

Answer/End/Reject A Call

Answer/End A Call: click once the MFB.
Reject A Call: double click the MFB.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
11

Activate Voice Command

Quickly triple click the MFB.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
12

Charge

Please use DC 5V adapter for charging. The green LED is on during charging. The white LED is on after fully charged.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
13

Low Battery

Battery is lower than 5%, prompt: battery low.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
14

Restore Factory Settings

Under power-off state, hold & press the MFB for 10 sec until the second time white and green LEDs flash.

Shenzhen Xingre Openear Waterproof Bone Conduction Headphones
15

Attentions
  1. Listening to loud music for a long time may cause discomfort, please use medium volume if possible. Do not use high volume for long periods of time.
  2. Using headphones will affect your perception of the surrounding environment. Pay more attention when using headphones.
  3. Do not remove or modify the headphone, as this may cause damage or burn out.
  4. Do not throw, twist on headphones or put them into a fire.
  5. Keep it away from fire, hydration and high pressure equipment.
  6. Not suitable for children under 10-year-old containing small parts.
  7. Do not classify it as household waste. Please send it to the local electrical equipment recycling station.
  8. When using the headset, do not exceed the depth of 2 meters underwater. It can be used in fresh water, tap water, swimming pool water, sea water, etc. It cannot be used in soapy water, body wash, shampoo or high temperature and high humidity environment.
  9. The charging pole piece has been treated for anti-corrosion, but the seawater is highly corrosive. It is recommended to clean it in time after soaking in seawater.

Note: The company does not assume any responsibility for the loss of personal property caused by the violation of the above warnings.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement. The device can be u sed in portable exposure condition without restriction