A PDi primary LCD TV mount is required to attach the TV(s) to this PDI-LCD-
GRID-MT or PDI-DUAL-GRID-MT. The primary LCD  The TV mount must match the VESA
mounting pattern of the TV to be mounted. For simplicity, only PDI-LCD-GRID-MT
is shown
Note: The maximum capacity for these mounts is 65 pounds.
Safety Steps:
- Always wear safety glasses/goggles to prevent injury from debris.
 - Follow the installation/removal instructions for your existing products.
 
Tool List:
- P1 or P2, Phillips screwdriver
 - 5/32″ Allen wrench
 - 3/16″ Allen wrench
 - 7/16″ Hex wrench
 - Safety glasses/goggles
 
Bill of Materials:
| Item | Part Number | Description | QTY | 
|---|---|---|---|
| 1 | PD122-001 | Synthetic Grease | 1 | 
| 2 | PD185-001 | Rotational Stop Collar | 2 | 
| 3 | PD198-003 | 10 ft. Power Cord | 1 | 
| 4 | PD235-002 | Loctite. #242 Blue | 1 | 
| 5 | PD240-001 | Upper Support | 1 | 
| 6 | PD240-002 | Lower Support | 1 | 
| PD240-003 or PD240-003-DUAL | Mounting Bracket | 1 | |
| 8 | PDI-590 | Sleeve | 2 | 
| 9 | PDIBHSCS252038 | 1/4-20 x 3/8″ Button Head Cap Screw | 2 (4 for PDI-DUAL- | 
GRID-MT)
10| PDIBHSCS252050| 1/4-20 x 1/2″ Button Head Cap Screw| 1
11| PDIBHSCS252062| 1/4-20 x 5/8″ Button Head Cap Screw| 1
12| PDINILN2520| 1/4-20 Nylock Nut| 6
13| PDIPPHMS2520200| 1/4-20 x 2″ Phillips Pan Head Machine Screw| 4
14| PDISHCS252020| 1/4-20 x 1/4″ Socket Head Cap Screw| 1
15| PDISHN2520| 1/4-20 Standard Hex Nut| 1  
Procedure
Mounting Upper Support
- Find desired mounting location and remove adjacent tiles for a workspace.
 - Place PD240-001 Upper Support (#5) on top of the tile, across the 24″ dimension, that the assembly will be mounted to, and string the required guy-wires but DO NOT attach to the PD240-001 Upper Support (#1). Verify the correct type of guy wire required per local building code.
 - Determine which of the three (3) sets of mounting holes will be used to provide the best placement for the installation.
 
Cut ONE of the 2-1/2″ x 3-3/4″ holes out of the tile and drill pilot holes (3/16″ diameter) for the four (4) mounting screws.
Assembling Lower Support
- Install one (1) PDIBHSCS252062 Screw (#11) and one (1) PDIHN2520 Standard Nut (#15) into the PD240-002 Lower Support (#6) as shown and securely tighten.
 - Install one (1) PDINILN2520 Nylock Nut (#12) to the PDIBHSCS252062 Screw (#11) as shown and securely tighten.
 - Install two (2) PDI-590 Sleeves (#8) into the PD240-002 Lower Support (#6) as shown and apply PD122-001 Synthetic Grease (#1) to surfaces of the PDI-590 Sleeves (#8).
 
Assembling Mounting Bracket Assembly
- 
Determine the desired mounting height for the LCD. Note: There must be a minimum of 12″ from the PD240-002 Lower Support (#6) to the bottom of the PD240-003 or PD240-003-DUAL Mounting Bracket (#7). There must also be a minimum of 2″ from the top of the upper PD185-001 Rotational Stop Collar (#2) and the top of the PD240-003 or PD240-003-DUAL Mounting Bracket (#7).
 - 
Slide one (1) PD185-001 Stop Collar (#2) over the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) and securely tighten at the desired mounting height.
 - 
Slide the PD240-002 Lower Support (#6) onto the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) until it rests on the PD185-001 Support Collar (#2) and install one (1) PD185-001 Rotational Stop Collar (#2) on top of the PD240002 Lower Support (#6). Securely tighten both PD185-001 Rotational Stop Collars (#2) at the desired mounting height.
Note: If additional clearance is needed in the ceiling, the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) can be trimmed to no less than 2″ above the upper PD185-001 Rotational Stop Collar (#2). If this is done, drill a new 17/64″ hole for the PDIBHSCS252050 Screw and deburr the inside of the tube to prevent damage to the cables. - 
Install one (1) PDIBHSCS2520 Screw (#10) from the inside of the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) as shown using one (1) PDINILN2520 (#12). This is a required safety screw.
 - 
Install one (1) PDISHCS252025 Screw (#14) with PD235-002 Loctite (#4), into the bottom PD185-001 Rotational Stop Collar (#2).
 
Attach the Mounting Bracket to the Ceiling
- Insert the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) through a hole in the ceiling tile and attach the PD240-002 Lower Support (#6) to the PD240-001 Upper Support (#5) with four (4) PDIPPHMS2520200 Screws (#13) and four (4) PDINILN2520 Nylock Nuts (#12). Be careful to not over-tighten the screws and crush the tile. Note: There must be a minimum of 12″ from the ceiling tile to the bottom of the PD240-003 or PD240-003-DUAL Mounting Bracket (#7).
 - Attach the guy wires to the PD240-001 Upper Support (#5).
 - Install the primary LCD TV mount(s) to the PD240-003 or PD240-003-DUAL Mounting Bracket (#7) using two (2) PDIBHSCS252038 Screws for each primary LCD TV Mount.
 
Optional Attachment of Outlet Electrical Box:
- Select an appropriately sized single gang “OLD WORK” or “REMODELING” electrical box.
 - Cut only ONE of the remaining rectangular holes in the PD240-001 Upper Support (#5) through the ceiling tile to match the electrical box.
 - Install the electrical box per the manufacturer’s instructions. Be careful not to over-tighten the screws and crush the tile.
 