OMCAN PT-CN-0390 Refrigerated Prep Tables Instruction Manual

June 5, 2024
OMCAN

OMCAN logo

Refrigerated Prep Tables
Models PT-CN-0390, 0580
Items 39592, 41145
Instruction Manual

OMCAN PT CN 0390 Refrigerated Prep Tables

STOP
DO NOT RETURN THIS PRODUCT TO THE STORE
For questions or assistance with this product call OMCAN Toll-Free: 1 800 465 0234 Customer Service or visit the Support section of www.omcan.com

Revised – 03/21/2022

QPS
APPROVED

Toll-Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com

Disclaimer

OMCAN IS NOT RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND HAS 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.

General Information

Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or negligent use of this equipment. The product shall only be operated by someone over the age of 18, of sound mind, and not under the influence of any drugs or alcohol, who has been trained in the correct operation of this machine and is wearing authorized proper safety clothing. Any modification to the machine voids any warranty and may cause harm to individuals using the machine or in the vicinity of the machine while in operation.

CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the external packaging, open the carton to ensure all ordered items are within the box, and there is no concealed damage to the machine. If the package has suffered rough handling, bumps, or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse for damaged products that were shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all operation and safety instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save these instructions for future reference. Also, save the original box and packaging for shipping the equipment if servicing or returning the machine is required.

Safety and Warranty

Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product. Consult Local and
National Standards to comply with the following:

  • Health and Safety at Work Legislation.
  • Fire Precautions.
  • IEE Wiring Regulations.
  • Building Regulations.

The appliance is intended for commercial use.

  • DO NOT attempt to service the item yourself.
  • DO NOT use damaged appliances. If you are in any doubt, consult Omcan.
  • DO NOT use electrical appliances inside the appliance (e.g. heaters, ice-cream makers, etc.), unless they are of the type recommended by the manufacturer.
  • Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
  • DO NOT use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • DO NOT damage the refrigerant circuit.
  • DO NOT stand or support yourself on the appliance or glass panel.
  • DO NOT allow oil or fat to come into contact with the plastic components. Clean immediately if contact occurs.
  • DO NOT place combustion, explosive or volatile article, corrosive acid or alkali, or liquid into the unit.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT use jet/pressure washers to clean the appliance.
  • DO NOT allow children to play with the packaging, and destroy plastic bags safely.
  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
  • Always switch off and disconnect the power supply to the unit before cleaning.
  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • For indoor use only. Not suitable for installation in an area where a water jet could be used. Must not be cleaned by a water jet.
  • To guarantee safe operation, ensure that the appliance is set up and connected as described in the instruction manual.
  • Any repairs and work on the appliance should only be carried out by the customer service department.
  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.

OMCAN IS NOT RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND HAS 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.
RESIDENTIAL USERS: The vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non- commercial or residential applications. The right is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as possible.

1 YEAR PARTS AND LABOUR WARRANTY

Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. The warranty covers electrical and part failures, not improper use.
Please seehttps://omcan.com/disclaimer for complete info.
WARNING:
The packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Technical Specifications

Model PT-CN-0390 PT-CN-0580
Temperature -2 to 8°C/28.4 to 46.4°F
Electrical 110V/60Hz/1
Capacity Power 190 W 290 W
Input Power 170 W 210 W
Refrigerant R134a, 230g
Consumption 2 kW/h
Capacity 390 L / 13.8 cu.ft. 580 L/20.5 cu.ft.
Granite Thickness 1.2″/30mm
Weight 216 lbs./98 kgs. 335 lbs./152 kgs.
Packaging Weight 249 lbs./113 kgs. 374.8 lbs./170 kgs.
Overall Dimensions 59.4″ x 31.5″ x 39″
1510 x 800 x 1000mm 79.7″ x 31.5″ x 39″

2025 x 800 x 1000mm
Interior Dimensions| 41.4″ x 24.8″ x 23.2″
1052 x 630 x 589mm| 61.5″ x 24.8″ x 28.7″
1562 x 630 x 729mm
Item Number| 39592| 41145

Installation

POSITIONING
Ensure that in respect of the unit dimensions, the space around the unit is suitable for both operation and easy maintenance. Place the cabinet on a flat and level surface with its adjustable legs. If the unit has been placed on its side, please keep the machine inactive for 2 hours so the condenser fluid can settle. Do not position close to any heat source, explosives, or in the path of direct sunlight. Air circulation must be freely maintained around the condensing unit. Failure to follow the above will cause damage to the unit and void the warranty.

ELECTRICAL CONNECTION
Check that the supply conforms to the requirements shown on the rating label. The connection must be grounded. The supply cable should never be stretched or pinched, keep the cable away from contact with liquids or heat sources. In the event of damage, it must be replaced by Omcan.

Operation

Turn on the unit by the switch, the control panel will display the current temperature inside the cabinet.

SETTING THE TEMPERATURE
By pressing the “SEL” button for one second, you will be able to read the set temperature. To change the temperature, press “SEL” and then press the “UP” or “DOWN” arrows to either increase or decrease the temperature as desired, confirm the new temperature by pressing “SEL”.

STORAGE OF FOODSTUFFS
In order to obtain the best possible function of the cabinet, it is necessary to observe the following:

  • Place the merchandise into the unit only after it has achieved the desired operating temperature on the display.
  • Do not place uncovered hot foods or liquids inside the unit.
  • Package or protect foods when possible.
  • Do not block the air circulation with the foodstuffs.
  • Avoid opening the doors/drawers for extended periods.
  • Wait a few moments before reopening the doors/drawers once they have been opened.
  • While stocking, only opens and fills one drawer at a time to eliminate the risk of overbalancing.

DEFROSTING

DEFROST TIMER
The electronic control panel automatically defrosts 4 times every 24 hours. The timer will reset to the time of the initial start-up. To modify the start time, press “DEF” for more than 5 seconds, and the cycle will begin immediately and continue 4 times every 24 hours.

Maintenance

INITIAL CLEANING
Before use, all parts of the cabinet should be cleaned.
For the walls and all the internal parts: use an antibacterial detergent.
For the plastic parts: use a moistened cloth.
Dry with a soft, clean cloth. Use little to no water.
Do not use harsh or abrasive solvents or detergents.
Always wear protective gloves when cleaning.

PERIODIC CLEANING
For hygienic reasons and for improved performance, clean the internal basin at least once a week. To do so, perform a defrost timer reset, when the defrost has completed, turn off the power and unplug the unit. Clean the unit as stated in “Initial Cleaning”.

CLEANING OF CONDENSER
For improved performance, clean the condenser at least once a week. Before cleaning, turn off the machine and disconnect from the power supply.

  • Unscrew, rotate and remove the protective grill.
  • Remove the dust on the front surface by using a brush and a vacuum cleaner, then reattach the protective grill.

PERIODS OF INACTIVITY
During periods of inactivity, remove all products from inside the cabinet and follow these instructions.

  • Remove the plug from the power supply and carefully clean the unit as stated in “Periodic Cleaning”.
  • Cover the cabinet with a cloth that allows air circulation in the interior.

Troubleshooting

Often, the malfunction of the unit is due to a simple cause and can be easily fixed without contacting Omcan for technical support. Please check the following:
If the cabinet does not operate, make sure that:

  • The plug has been correctly inserted into the socket.
  • The supply cord is not damaged.

If the required temperature is not reached, make sure that:

  • The command switch is turned on.
  • The electronic control panel is correctly regulated.
  • The cabinet is not in the defrosting phase or the post defrosting phase.
  • The evaporator is not covered with frost.
  • The condenser is not blocked with dust.
  • The cabinet is not located near heat sources or its condensing unit has uninterrupted airflow.
  • The stored foods or other objects do not inhibit the proper closing of the unit.
  • The cabinet is not working in proper working conditions (overloaded, hot food, blocked circulation, etc.).

If the cabinet leaks water, make sure that:

  • The collecting container or the device for condensing water elimination are not damaged.
  • The discharge outlets are not blocked or obstructed.
  • The cabinet has been properly leveled.
  • The door seal heater is operating.

If the cabinet is unusually noisy, make sure that:

  • The frame does not have any loose screws or bolts.
  • The cabinet has been placed in a flat, stable position.

If after all the above has been followed that the malfunction continues, it is advised that you call Omcan for service. Be prepared to supply the following information:

  • The model name.
  • The item number.
  • The serial number.
  • The error code is displayed on the control panel.

All spare parts must be replaced by Omcan or an Omcan authorized service company

Parts Breakdown

Model PT-CN-0390 39592

OMCAN PT CN 0390 Refrigerated Prep Tables - Parts
Breakdown

Item No.| Description| Position| Item No.| Description| Position| Item No.| Description| Position
---|---|---|---|---|---|---|---|---
AF205| Body for 39592| 1| AF221| Front Support Right for 39592| 17| AF235| Filter Drier for 39592| 33
AF206| Door Right for 39592| 2| AF222| Back Support Right for 39592| 18| AF236| Capillary for 39592| 34
AF207| Door Left for 39592| 3| AF223| Evaporator Cover for 39592| 19| AF237| Filter for 39592| 35
AF208| Gasket for 39592| 4| AF224| Top for 39592| 20| AF238| Unit Board for 39592| 36
AF209| Up Hinge Right for 39592| 5| AF225| Sensor for 39592| 21| AD819| Power Cord for 39592| 37
AF210| Door Spring for 39592| 6| AF226| Probe Padding for 39592| 22| AF239| Water Box for 39592| 38
AF211| Down Hinge Right for 39592| 7| AF227| Fan Support for 39592| 23| AF240| Front Panel Up Hinge for 39592| 39
AF212| Down Hinge Left for 39592| 8| AD825| Condenser Fan for 39592| 24| AF241| Water Box Protector for 39592| 40
AF213| Up Hinge Left for 39592| 9| AF228| Evaporator for 39592| 25| AF242| Clip for 39592| 41
AF214| Fixed Front Panel for 39592| 10| AE752| Grill for 39592| 26| AF243| Front Panel Down Hinge for 39592| 42
AF215| Air Flow Conduct Board for 39592| 11| AF229| Compressor for 39592| 27| AF244| Front Panel for 39592| 43
AF216| Set Guide Left for 39592| 12| AF230| Hot Pipe for 39592| 28| AD829| Main Switch for 39592| 44
AF217| Shelf for 39592| 13| AF231| Condenser Fan for 39592| 29| AD818| Thermostat for 39592| 45
AF218| Set Guide Right for 39592| 14| AF232| Condenser Fan Blade for 39592| 30| AF245| Lock for 39592| 46
AF219| Front Support Left for 39592| 15| AF233| Basket Guard Grills for 39592| 31| AF246| Foot for 39592| 47
AF220| Back Support Left for 39592| 16| AF234| Condenser for 39592| 32| AF247| Water Box for 39592| 48

Model PT-CN-0580 41145

OMCAN PT CN 0390 Refrigerated Prep Tables - Parts Breakdown
1

Item No.| Description| Position| Item No.| Description| Position| Item No.| Description| Position
---|---|---|---|---|---|---|---|---
AF248| Body for 41145| 1| AF221| Front Support Right for 41145| 17| AF235| Filter Drier for 41145| 33
AF249| Door Right for 41145| 2| AF222| Back Support Right for 41145| 18| AF236| Capillary for 41145| 34
AF250| Door Left for 41145| 3| AF223| Evaporator Cover for 41145| 19| AF237| Filter for 41145| 35
AF208| Gasket for 41145| 4| AE751| Marble Countertop for 41145| 20| AF238| Unit Board for 41145| 36
AF209| Up Hinge Right for 41145| 5| AF225| Sensor for 41145| 21| AD819| Power Cord for 41145| 37
AF210| Door Spring for 41145| 6| AF226| Probe Padding for 41145| 22| AF239| Water Box for 41145| 38
AF211| Down Hinge Right for 41145| 7| AF227| Fan Support for 41145| 23| AF240| Front Panel Up Hinge for 41145| 39
AF212| Down Hinge Left for 41145| 8| AD825| Condenser Fan for 41145| 24| AF241| Water Box Protector for 41145| 40
AF213| Up Hinge Left for 41145| 9| AF228| Evaporator for 41145| 25| AF242| Clip for 41145| 41
AF214| Fixed Front Panel for 41145| 10| AE752| Grill for 41145| 26| AF243| Front Panel Down Hinge for 41145| 42
AF251| Air Flow Conduct Board for 41145| 11| AF252| Compressor for 41145| 27| AF244| Front Panel for 41145| 43
AF216| Set Guide Left for 41145| 12| AF230| Hot Pipe for 41145| 28| AD829| Main Switch for 41145| 44
AF217| Shelf for 41145| 13| AF231| Condenser Fan for 41145| 29| AD818| Thermostat for 41145| 45
AF218| Set Guide Right for 41145| 14| AF232| Condenser Fan Blade for 41145| 30| AF245| Lock for 41145| 46
AF219| Front Support Left for 41145| 15| AF233| Basket Guard Grills for 41145| 31| AF246| Foot for 41145| 47
AF220| Back Support Left for 41145| 16| AF234| Condenser for 41145| 32| AF247| Water Box for 41145| 48

Model PT-CN-0390 39592
Model PT-CN-0580 41145

OMCAN PT CN 0390 Refrigerated Prep Tables - Electrical
Schematics

Notes

Warranty Registration

Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: https://omcan.com/warranty-registration/

For mailing in Canada
OMCAN
PRODUCT WARRANTY REGISTRATION
3115 Pepper Mill Court,
Mississauga, Ontario
Canada, L5L 4X5

|

For mailing in the US
OMCAN
PRODUCT WARRANTY REGISTRATION
4450 Witmer Industrial Estates, Unit 4,
Niagara Falls, New York
USA, 14305

---|---

or email to: service@omcan.com

Purchaser’s Information

Name:——————————————————————————————————————————
Address:—————————————————————————————————————————
City:—————————- Province or State:—————————— Postal or Zip:——————————
Country:—————————————————————————————————————————
The dealer from which Purchased:——————————————————————————————–
Dealer City:———————————————–Dealer Province or State:—————————————–
Invoice:—————————————————————————————————————————-
Model Name:——————————————Model Number:——————————————————-
Machine Description:———————————————————————————————————–
Date of Purchase (MM/DD/YYYY):—————————————————————————————-
Would you like to extend the warranty? ▢ Yes ▢ No| Company Name:———————————————–
Telephone:——————————————————
Email Address:————————————————-
Type of Company:
▢ Restaurant ▢ Bakery ▢ Deli
▢ Butcher ▢ Supermarket ▢ Caterer
▢ Institution (specify):—————————————-
▢ Other (specify):———————————————
Serial Number:————————————————-
Date of Installation (MM/DD/YYYY):——————
---|---

Thank you for choosing Omcan

OMCAN logo

Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American foodservice industry. Our success over these many years can be attributed to our commitment to strengthening and developing new and existing relationships with our valued customers and manufacturers. Today with partners in North America, Europe, Asia, and South America, we continually work to improve and grow the company. We strive to offer customers exceptional value through our qualified local sales and service representatives who provide convenient access to over 6,500 globally sourced products.

OMCAN PT CN 0390 Refrigerated Prep Tables - Icon

http://www.omcan.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OMCAN User Manuals

Related Manuals