Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or negligent use of this equipment. The product shall only be operated by someone over the age of 18, of sound mind, and not under the influence of any drugs or alcohol, who has been trained in the correct operation of this machine, and is wearing authorized, proper safety clothing. Any modification to the machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of the machine while in operation.

CHECK PACKAGE UPON ARRIVAL

**** Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the external packaging, open carton to ensure all ordered items are within the box, and there is no concealed damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse for damaged products that were shipped collect or third party.

Before operating any equipment, always read and familiarize yourself with all operation and safety instructions.

**Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save these instructions for future reference. Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required.**

Safety and Warranty

RESIDENTIAL USERS: Vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non- commercial or residential applications. The right is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as possible.

Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule a drop off to either an Omcan authorized service depot in the area, or to an Omcan Service warehouse to repair the equipment.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
Please see https://omcan.com/disclaimer for complete info.

**WARNING:**

The packaging components (cardboard, polyethylene, and others) are classified as normal solid urban waste and can therefore be disposed of without difficulty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Technical Specifications

Model DI-CN-0099
Capacity 10 L / 10.6 QT
Electrical 110V / 60Hz / 1
Power 150 W
Precision/cc ± 1cc
Number of Keys 16
Auto Cleaning Yes
Output Port Material Aluminum Alloy
Default Temperature for Barrel 25°C / 77°F
Dimensions 9.8” x 9.8” x 16.1” / 250 x 250 x 410mm
Weight 28.7 lbs. / 13 kgs.
Item Number 44645

Operation

DISPLAY PANEL
Number Name Function
1 Heating Light When the temperature of the liquid in bucket is below 25°C,

the heating

light will be on. The machine will begin to heat.

2| Feed Light| When the liquid is below the caution line, the feed light will be on and beep.
3| Filling Light| While the liquid output operation is going, the filling light is on.
4| Power Button| Powers the machine.


5

| Continuous Output/ Stop| When the machine is in the standby state, press this button to go into the continuous output state. When the machine is in the output state, press this button to stop the output.

OPERATION

  1. Turn on/off the machine.
    – Connect the power switch to power the machine.
    – Press the power button for more than 1 second. The LED will display “AUTT” with 2 beeps. The machine will be in standby mode.
    Attention: It is suggested that the machine should be cleaned before it’s first use or after idling for an extended period of time.

  2. Sugar output.
    – When the machine is in the standby state, press any of the numbered buttons (ex: 4-1) to enter the output state.
    – Press the continuous output/stop button to exhaust up air before other setting or operating during daily use.
    – Press the continuous output/stop button to stop output and return to the standby state.

  3.  Alarm for low liquid.
    – When the liquid is below the position of the level sensor, an alarm will sound (5 seconds of beeps). The feed light will be on and the LED display will show “LL”.

  4. Measurement type.
    – By setting the “FP” value to choose between weight (g) or volume (cc).

  5. Sugar outlet auxiliary heating function.
    – Turn on the sugar outlet “heating switch” to heat the sugar outlet. This operation can avoid clogging of the
    outlet if the temperature is too cold or the sugar is viscid. This switch can be turned off if the temperature is above 15°C.

  6. Auto washing function.
    – Before cleaning the machine, open the sugar outlet, load some war water (below 60°C) and put a container under the outlet. Long press the “save” button for 3 seconds to go into the auto washing state. Meanwhile the water will flow out from the outlet. This operation will last 3 minutes. It is suggested to wash the machine after daily operations to keep cleared.

SETTINGS

In the standby state, press the setting button to go into the setting state, “F—”, then press the up or down key to page up or page down.

“FL–” Check or set output values.
“FP–” Set precision setting.
“FH–” Set bucket temperature.

Press the setting button again to confirm the setting. If there is no operation, the machine will leave the setting state.

DEFAULT VALUES

Button| Output Quantity| Button| Output Quantity| Button| Output Quantity| Button| Output Quantity
---|---|---|---|---|---|---|---
1-1| 6| 2-1| 14| 3-1| 22| 4-1| 30
1-2| 8| 2-2| 16| 3-2| 24| 4-2| 35
1-3| 10| 2-3| 18| 3-3| 26| 4-3| 40
1-4| 12| 2-4| 20| 3-4| 28| 4-4| 45

OUTPUT PRECISION SETTING (FP–)

**** Calibration is necessary before the first time operation or when not in use for extended periods of time. Please set the following steps to set “FP–”:

Step 1| Press the setting button, the LED will display “FL–”. Press the up or down keys to turn to “FP–”.
---|---
Step 2| Press the setting button again to go into the setting state. The LED displays “F390” (The default value is “P390”).
Step 3| Press up or down to increase or decrease the output quantity.
The actual output quantity may be different from the normal quantity by a small margin.
Step 4| Press save to save and quit. Press top to cancel and quit.

Note: Just the maximum and minimum quantity should be set.

TEMPERATURE PARAMETER SETTING (FH–)

** During the “FH–” state, while displaying “=25C”, press up or down to set the temperature.
Attention: “=0C” will turn off the heating function and the unit will enter the heat preservation state.**

Troubleshooting

Cause Troubleshooting
Outlet sugar leaks. The outlet is incorrectly installed.

The rubber ring is worn out.
Sugar liquid cannot flow out.| The sugar is frozen. Try using the auxiliary heating switch.
If the sugar liquid is too thin, change the heating temperature.
Press the continuous output/stop button to exhaust up air.
Problem with heating system.| Reset to default temperature 25°C, if the liquid is boiling, that means the

PCB has failed.

The flow does not stop naturally.| The controller PCB has failed.
The machine cannot be powered on.| The fuse broke and must be replaced.
The error is too large.| Adjust the FP, or check whether the sugar is empty.

Parts Breakdown

Model DI-CN-0099 44645

Parts Breakdown

Model DI-CN-0099 44645

Item No.| Description| Position| Item No.| Description| Position| Item No.| Description| Position
---|---|---|---|---|---|---|---|---
AG576| Outside Panel 16 for 44645| 1| AG580| Motor for 44645| 5| AG584| Output Port Assembly for 44645| 9
AG577| Outside Panel 24 for 44645| 2| AG581| Electronic Eye Assembly for 44645| 6| AG585| Power Cable for 44645| 10
AG578| Inside Panel (PCB) for 44645| 3| AG582| Body Shell for 44645| 7| AG586| Cable for 44645| 11
__

AG579

| __

Pump Assembly for 44645

| __

4

| __

AG583

| __

Key Shell for 44645

| __

8

| __

AG587

| PCB Caps (Green Small for Motor) for 44645| __

12

Electrical Schematics

Model DI-CN-0099 44645

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals