Disclaimer

OMCAN IS NOT RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.

General Information

Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or negligent use of this equipment. The product shall only be operated by someone over the age of 18, of sound mind, and not under the influence of any drugs or alcohol, who has been trained in the correct operation of this machine, and is wearing authorized, proper safety clothing. Any modification to the machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of the machine while in operation.

CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the external packaging, open carton to ensure all ordered items are within the box, and there is no concealed damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse for damaged products that were shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all operation and safety instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save these instructions for future reference. Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required.

Safety and Warranty

SAFETY CAUTIONS

  1. This unit uses AC110V/60Hz power, there should be a 500VA stabilizer if the voltage fluctuation exceed AC198V~242V.
  2. The user should hold the plug when the power is on/off, dragging or pulling the power cord is prohibited.
  3. Do not remove the power cord or plug.
  4. Must use dependent socket and reliable ground wire. Ground wire must not connect with the null line of the gas pipe, warm gas pipe, water pipe and must be single power.
  5.  Never splash water on the unit directly.
  6. Keep away from explosive, hazardous goods such as ether, gas, alcohol, bonding agents, gunpowder etc.
  7. Keep away from spray of inflammables such as paints, coating materials etc.
  8. After the unit is switched off, it should not be restarted within 5 minutes.
  9. Do not leave the power cord under any heavy objects including the unit itself.
  10. Do not drill holes or install other objects on the casing.
  11. This cooler is not suitable for storage pharmaceutical products.

CAUTION

  • The unit is not suitable for storage of blood, pharmaceutical products and biological products
  • Do not place heavy articles on the top of the unit.
  • In case of trouble, please ask professional person for service, do not dismantle the unit without prior authority to avoid hazard.

RESIDENTIAL USERS: Vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non-commercial or residential applications. The right is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as possible.

1 YEAR PARTS AND LABOUR WARRANTY
Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
Please see https://omcan.com/disclaimer for complete info.

WARNING:
The packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Technical Specifications

Model| FR-CN-0105| I FR-CN-0105B| FR-CN-0098NB| I FR- CN-0098
---|---|---|---|---
Capacity| 105 L / 3.7 cu.ft.| 98 L / 3.46 cu. ft.
Power| 180 W| 158 W
Power Consumption| 2.3 kW/h| 3.3 kW/h
Temperature Range| -18 to -20°C / -0.4 to -4°F
Refrigerant| R290
Maximum Ambient Temperature| 32°C / 90°F
Defrosting| Manual
Temperature Controller| Digital Controller
Number of Shelves| 6| 3
Shelf Material| Metal| I ABS
Shelf Capacity| 33.1 lbs. / 15 kgs.
Shelf Dimensions| 10.2″ x 10.2″
260 x 260mm| 17.4″ x 15″
442 x 380mm| 17.8″ x 14.2″
453 x 360mm
17.8″ x 6.7″
453 x 170mm
Electrical| 110V / 60Hz
Interior Dimensions| 11″ x 12.2″ x 49.8″
280 x 310 x 1265mm| 17.9″ x 15.4″ x 26.8″
455 x 390 x 680mm| 17.8″ x 14.2″ x 25.6″
453 x 360 x 650mm
Exterior Dimensions| 16.5″ x 16.9″ x 69.1″
420 x 430 x 1755mm| 16.5″ x 16.9″ x 74.2″
420 x 430 x 1885mm| 23.4″ x 20.1″ x 33.8″
595 x 510 x 859mm| 23.4″ x 21.5″ x 34.3″
595 x 545 x 870mm
Weight| 121.3 lbs. / 55 kgs.| 143.3 lbs. / 65 kgs.| 110.2 lbs / 50 kgs.
Item Number| 47241| 47242| 47239| I 44526

Installation

INSTALLATION AND STORAGE

  1. Keep the unit vertical when carrying the unit, the angle to the horizontal line should not be over 50°, otherwise it will damage the compressor and affect normal  operation of the unit.
  2. The unit should be place on a solid and firm ground, take away the bottom pack to lower the shock and noise.
  3. Leave at least 20 cm of distance between the back of the unit and the wall for ventilation and leave a space with an open angle of 160° for the door.
  4. Keep the unit away from heat sources and avoiding direct sunlight.
  5. Never place the unit on a location where water can reach or with high moisture. Splashed water and dirt should be wiped off in time by using a soft cloth.
  6. Do not place the unit in the environment cold enough to be iced.

BEFORE USE

  1. Remove the carton and packing foam (including the bottom foam) before using.

  2. Clean the unit before using.

  3. Adjust the foot to make the unit steady according to the ground condition to lower the shock and noise.

  4. After moving the unit, place the unit for 30 minutes before switching it on.
    Running: close the door and connect the power, turn on the lamp switch on the control panel, the lamp is on.
    Half an hour later, the temperature inside the case lower apparently, it indicates the unit on be normally used.

  5. After connecting the power, the unit should be kept empty for one hour.

Operation

SETTING AND ADJUSTING THE TEMPERATURE

  1. Adjust the storage temperature through the temperature controller located on the back of the case, adjust the temperature according to the ambient temperature and the foodstuff.
  2. See the following picture about the knob scale. The temperature adjustable capacity is from “1”-“5”, adjust the storage temperature by turning the temperature controller clockwise. The higher of the number shows the lower of the storage temperature. The knob can turn freely but can’t turn clockwise from “5” to “1”. Factory setting position is on “3”.
  3. Check if the scale is on an appropriate position before using, frequent adjustment is not appropriate when using. Normally in summer, the ambient temperature is high, anti clockwise turn the knob to “2”, while in winter, the ambient temperature is low, clockwise turn the knob to “4”.
  4. Position “0” represent stop running.

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 1

STORAGE OF PRODUCT

  1. Do not put large amount of product into the unit at one time, you should leave some space around the foodstuff to let cold air inside the cabinet counter to flow. Keep bottled articles away from the walls of interior cabinet so as not to freeze it until broken.
  2. Do not put warm food into the unit directly until they are cooled under normal temperature, it will facilitate to lower its energy consumption and prolong service life of the compressor.

Maintenance

DISCONNECT THE POWER SUPPLY BEFORE MAINTENANCE FOR THE MACHINE!

  1. Keep the door gasket clean, remove it from the door and wash it. Dry and seal it as before. Putting some talcum powder on the magnetic surface would prolong its service life.
  2. Bulb replacement: remove the lamp shade, take out the bulb, replace with a new bulb, then mount it again.
  3. If there is heavy frost on the evaporator after long usage, take out the stuff inside the case, disconnect the power, the frost will melt automatically, clean up the water and connect the power again.
  4. Use a soft cloth and dip some water or soap (Non-caustic, neutral detergent is also available) to clean the unit. Dry the unit after cleaning to avoid rust.
  5. Do not use organic liquid, boiled water, washing powder or acid stuff to clean the unit. Rinsing the case by water is not allowed, don’t use hard brush, steel brush to clean the case.
  6. If the unit will not be used for a long time, disconnect the power, clean it by following the above steps, wipe off the water inside the case with a soft cloth.

Troubleshooting

Problems Possible Causes Solutions
The units does not work. Bad connection of plug. Re-connect the plug to

power supply
Abnormal operation of the compressor or has buzz sound.| The power voltage is out of the rated range.| Disconnect the power supply immediately and reconnect with it after normal voltage. It is necessary to have a voltage
stabilizer in case of poor power supply.
Compressor operates too long time and no frost on the surface of inner cabinet.| Refrigeration system is at fault (leakage or blocked).| Send the unit to service department for repair.
There is frost or ice on the walls of the inner cabinet and too low internal temperature, the compressor operates never stop.| Thermostat does not work.| Ask service department for repair.
The internal temperature is too high and the compressor operates never stop.| Bad heat dissipation and ventilation of casing, the ambient temperature is too high.| Improve ventilation and lower the ambient temperature.
Too much warm food was put in at one time.| Take out some food.
Door open frequently and long time door opening.| Decrease number and time of door opening.
Too high noise.| The unit is not level.| Adjust the adjustable legs.
The fastener of the unit is loose.| Fasten the loose fastener.
Pipes are touching the compressor.| Careful separate the touched pipes.
Light is not on.| The light is burned out.| Replace the light.

NORMAL PHENOMENA

  1. Sometime hear light sound of water flowing in the unit, this is the sound of refrigerant flowing inside the pipe.
  2. The top, and the two sides of the casing will be warm, even too hot.
  3. In a humidity place, there is dew on the casing or the door, it can dry by dry cloth.

Parts Breakdown

Model FR-CN-0105 47241
Model FR-CN-0105B 47242

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 2

Model FR-CN-0105 47241

Item No. Description Position
AH263 Top Panel for 47241 1
AH264 Digital Temperature Controller for 47241 2
AH265 On/Off Button for 47241 3
AH266 Back Panel for 47241 4
AH267 Transformer for LED for 47241 5
AH268 Lamp Holder for 47241 6
AH269 LED Tube for 47241 7
AH270 Case for 47241 8
AH271 Condenser for 47241 9
AH272 Inner LED Lamp for 47241 10
AH273 Lampshade for 47241 11
AH274 Evaporation Fan for 47241 12
AH275 Power Line for 47241 13
AH276 Seal Plate for Compressor Room for 47241 14
AH277 Base Foot for 47241 15
AH278 Compressor for 47241 16
AH279 Bottom Plate for Compressor for 47241 17
AH280 Filter Drier for 47241 18
AH281 Heat Elimination Fan for 47241 19
AH282 Front Bottom Panel for 47241 20
AH283 Connector for Front Bottom Panel for 47241 21
AH284 Hinge Down for 47241 22
AH285 Glass Door for 47241 23
AH286 Shelf Holder for 47241 24
AH287 Stand Column for 47241 25
AH288 Hinge Upper for 47241 26
AH289 Top Frame for Light Box for 47241 27
AH290 Lamp Plate for 47241 28
AH291 Shelf for 47241 29

Model FR-CN-0105B 47242

Item No. Description Position
AH311 Top Panel for 47242 1
AH312 Digital Temperature Controller for 47242 2
AH313 On/Off Button for 47242 3
AH314 Back Panel for 47242 4
AH315 Transformer for LED for 47242 5
AH316 Lamp Holder for 47242 6
AH317 LED Tube for 47242 7
AH318 Case for 47242 8
AH319 Condenser for 47242 9
AH320 Inner LED Lamp for 47242 10
AH321 Lampshade for 47242 11
AH322 Evaporation Fan for 47242 12
AH323 Power Line for 47242 13
AH324 Seal Plate for Compressor Room for 47242 14
AH325 Base Foot for 47242 15
AH278 Compressor for 47242 16
AH327 Bottom Plate for Compressor for 47242 17
AH328 Filter Drier for 47242 18
AH329 Heat Elimination Fan for 47242 19
AH330 Front Bottom Panel for 47242 20
AH331 Connector for Front Bottom Panel for 47242 21
AH332 Hinge Down for 47242 22
AH333 Glass Door for 47242 23
AH334 Shelf Holder for 47242 24
AH335 Stand Column for 47242 25
AH336 Hinge Upper for 47242 26
AH337 Top Frame for Light Box for 47242 27
AH338 Lamp Plate for 47242 28
AH339 Shelf for 47242 29

Model FR-CN-0098NB 47239

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 3

Model FR-CN-0098NB 47239

Item No. Description Position
AD668 Mesh Enclosure for 47239 1
AC789 Screw for 47239 2
AC790 Temperature Control Knob for 47239 3
AC791 Lamp Switch for 47239 4
AC792 Temperature Controller Holder for 47239 5
AC793 Temperature Controller for 47239 6
AC794 Power Line for 47239 7
AC795 Body for 47239 8
AC796 Top Hinge Box Buckle for 47239 9
AC797 M4 Nut for 47239 10
AC798 Top Hinge Box for 47239 11
AC799 M5 Nut for 47239 12
AC800 Gasket for 47239 13
AC801 Lock Washer for 47239 14
AC802 Top Hinge for 47239 15
AC803 Big Shelf for 47239 16
AC804 Small Shelf for 47239 17
AC805 Door Gasket for 47239 18
AC806 Glass Door for 47239 19
AC807 Hinge for 47239 20
AC808 Base Angle for 47239 21
AC809 M6 Nut for 47239 22
AH278 Compressor for 47239 23
AC811 M6 Nut for 47239 24
AC812 Floor Presser for 47239 25
AC813 M6 Nut for 47239 26
AC814 Lock Washers for 47239 27
AC815 N6 Nut for 47239 28
AC816 Base Angle for 47239 29
AC817 Condenser for 47239 30
AC818 Draught Fan for 47239 31

Model FR-CN-0098 44526

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 4

Model FR-CN-0098 44526

Item No. Description Position
AH292 Ventilation Grill for 44526 1
AH293 Upper Hinge for 44526 2
AH294 Condenser for 44526 3
AH295 Bottom Panel for 44526 4
AH296 Feet for 44526 5
AH278 Compressor for 44526 6
AH298 Fan Motor for 44526 7
AH299 Lock for 44526 8
AH300 Door for 44526 9
AH301 Bottom Hinge for 44526 10
AH302 Shelf for 44526 11
AH303 Light for 44526 12
AH304 Light Box for 44526 13
AH305 Cabinet for 44526 14
AH306 Plug for 44526 15
AH307 Temperature Control for 44526 16
AH308 On/Off Switch for 44526 17
AH309 Bracket for Light for 44526 18
AH310 Top Light for 44526 19

Electrical Schematics

Model FR-CN-0105 47241

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 5

Model FR-CN-0105B 47242

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 6

Model FR-CN-0098NB 47239

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 7

Model FR-CN-0098 44526

OMCAN FR-CN-0105 60-inches Chest Freezer - fig 8

Warranty Registration

Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting:

https://omcan.com/warranty-registration/

For mailing in Canada
OMCAN
PRODUCT WARRANTY REGISTRATION
3115 Pepper Mill Court,
Mississauga, Ontario
Canada, L5L 4X5| For mailing in the US
OMCAN
PRODUCT WARRANTY REGISTRATION
4450 Witmer Industrial Estates, Unit 4,
Niagara Falls, New York
USA, 14305
---|---

or email to: service@omcan.com

Purchaser’s Information
Name:………….
Address:………………………..
City:………………. Province or State:………… Postal or Zip:
Country:…………..
Dealer from which Purchased:………………………
Dealer City:……………………………. Dealer Province or State:…………………..
Invoice:…………….
Model Name:…………………….. Model Number:……………….
Machine Description:……………..
Date of Purchase (MM/DD/YYYY):……………..
Would you like to extend the warranty? □Yes □ No
Company Name:………..
Telephone:…………..
Email Address:………………….
Type of Company:………………..
□ Restaurant □ Bakery □ Deli
□ Butcher □ Supermarket □ Caterer
□ Institution (specify):……………..
□ Other (specify):…………….
Serial Number:…………….
Date of Installation (MM/DD/YYYY):……………….

Thank you for choosing Omcan

Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers. Today with partners in North America, Europe, Asia and South America, we continually work to improve and grow the company. We strive to offer customers exceptional value through our qualified local sales and service representatives who provide convenient access to over 6,500 globally sourced products.

OMCAN - logo

Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com

OMCAN FR-CN-0105 60-inches Chest Freezer - icon 1

OMCAN FR-CN-0105 60-inches Chest Freezer - qr code

http://www.omcan.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals