inels RFSA-61M-MI Wireless Switch Unit Instruction Manual

June 5, 2024
inELS

inels RFSA-61M-MI Wireless Switch Unit Instruction Manual

inels RFSA-61M-MI Wireless Switch Unit

Characteristics

  • RFSA-61M/MI: the switching unit with 1 output channel is used for controlling appliances, sockets or lights.
    – The one-module design of the unit into a switchboard enables connection of a switched load up to 16 A (4.000 W).
    – The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller).

  • RFSA-66M/MI: the switching unit with 6 output channels is used for independent control of up to 6 appliances, sockets or lights. It is possible to assign any function to each output relay.
    – The three-module design of the unit into a switchboard enables connection of a switched load 6 x 8A (6 x 2000 W).
    – It is just right for creating scenes, where with one push of the controller, you can switch on or off all 6 channels simultaneously.
    – Each of the channels may be controlled by up to 25 channels (1 channel represents one button on the controller).

  • They can be combined with detectors, controllers, iNELS RF Control or system components.

  • The integrated switching contact enables connection, where the controlled appliance may be switched on or off by command.

  • Function: button, impulse relay and time function of delayed start or return with time setting range of 2s-60 min.

  • The programming button on the unit is also used for manual control of the output.

  • For components with an antenna connector, the package includes an internal AN-I antenna; if the component is placed in a sheet metal cabinet, you can use an external AN-E antenna to improve the signal.

  • Memory status can be pre-set in the event of a power failure.

  • For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.

  • Range up to 200 m (in open space ), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.

  • Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).

  • The RFSA-61M/MI and RFSA-66M/MI components are not intended for installation in closed all-metal switchboards, conversely, they are designed for plastic sub-switchboards.

Assembly

mounting into switchboard

FIG 1 Assembly

Connection

FIG 2 Connection

Radio frequency signal penetration through various construction materials

FIG 3 Radio frequency signal penetration through various construction
materials

Indication, manual control

FIG 4 Indication, manual control

FIG 5 Indication, manual control

  • LED Un – green – power supply indication.

  • LED STATUS – red – status indication of individual channels.
    Indicators of memory function:
    On – LED blinks x 3.
    Off – The LED lights up once for a long time.

  • Manual control is performed by pressing the PROG button for less than 1s.

  • Programming is performed by pressing the PROG button for more than 1s.
    In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.

Compatibility

FIG 6 Compatibility

The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.

Functions and programming with RF transmitters

Function button

Description of button

The output contact will be closed by pressing the button and opened by releasing the button.
For the correct execution of individual commands (press = closing / releasing the button = opening), the time delay between these commands must be a min of . 1s (press – delay 1s – release).

Programming

FIG 8 Programming

FIG 9 Programming

FIG 10 Programming

Function switch on

Description of switch on

FIG 11 Description of switch on

Programming

FIG 12 Programming

FIG 13 Programming

FIG 14 Programming

Function switch off

Description of switch off

The output contact will be opened by pressing the button.

Programming

FIG 16 Programming

FIG 17 Programming

FIG 18 Programming

Function impulse relay

Description of impulse relay

The output contact will be switched to the opposite position by each press of the button. If the contact was closed, it will be opened and vice versa.

Programming

FIG 20 Programming

FIG 21 Programming

Function delayed off

The output contact will be closed by pressing the button and opened after the set time interval has elapsed.

Programming

FIG 23 Programming

Function delayed on

Description of delayed on

The output contact will be opened by pressing the button and closed after the set time interval has elapsed.

Programming

FIG 25 Programming

FIG 26 Programming

FIG 27 Programming

Programming with RF control units

FIG 28 Programming with RF control units

RFSA-61M/MI: the address listed on the front side of the actuator is used for programming and
controlling an RF actuator by control units.

RFSA-66M/MI: addresses listed on the front side of the actuator are used for programming and controlling the actuator and individual RF channels by control units.

Delete actuator

Deleting one position of the transmitter

By pressing the programming button on the actuator for 5 seconds, deletion of one transmitter activates. LED flashs 4x in each 1s interval.
Pressing the required button on the transmitter deletes it from the actuator’s memory.

To confirm deletion, the LED will confi rm with a fl ash long and the component returns to the operating mode. The memory status is not indicated.

Deletion does not affect the preset memory function.

Deleting the entire memory

By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED flashs 4x in each 1s interval.

The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.). You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode.

Deletion does not affect the pre-set memory function.

Selecting the memory function

Press of programming button on receiver RFSA-61M/MI (66M/MI) for 1 second will activate receiver RFSA-61M/MI (66M/MI) into programming mode. LED is fl ashing in 1s interval.

Pressing the programming button on the RFSA-61M/MI (66M/MI) receiver for less than 1 second will finish the programming mode, this will reverse the memory function. The LED lights up according to the current pre-set memory function. The set memory function is saved.

Every other change is made in the same way.

• Memory function on:

  • For functions 1-4, these are used to store the last state of the relay output before the supply
    voltage drops, the change of state of the output to the memory is recorded 15 seconds after
    the change.

  • For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.

• Memory function off:
When the power supply is reconnected, the relay remains off.

Technical parameters

FIG 33 Technical parameters

FIG 34 Technical parameters

  • Max Tightening Torque for antenna connector is 0.56 Nm.

Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units. Between the individual commands must be an interval of at least 1s.

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.

RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.

ELKO EP declares that the RFSA-61M/MI, RFSA-66M/MI type of equipment complies with Directives 2014/30/EU, 2011/65/EU, 2015/863/EU and
2014/35/EU. The full EU Declaration of Conformity is available at:
www.elkoep.com/wireless-switch-unit-multi-function-1-output-rfsa-61m
www.elkoep.com/wireless-switch-unit—6-outputs-rfsa-66m
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
Tel.: +420 573 514 211, e-mail: elko@elkoep.com, www.elkoep.com

ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
ELKO EP SLOVAKIA, s.r.o. | Fraňa Mojtu 18, 949 01 Nitra | Telefón:

+421 37 6586 731 | E-mail: elkoep@elkoep.sk

www.elkoep.com / www.elkoep.sk

Product Standard

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

inELS User Manuals

Related Manuals