Combisteel 7464.0085 Refrigerator Glass Door
INTRODUCTION
This operation manual has been designed to facilitate the use of your single
door cooler with maximum efficiency over the years. In all of the
manufacturing processes “environmentally friendly” technologies are used as
well as materials and refrigerants that are not harmful to the nature. Please
read this manual carefully before you start operating your cooler in order to
prevent user defects and ensure maximum efficiency from this product that has
been manufactured to serve you over the years.
Detect the cooler immediately on delivery for any damage. In case of any
damage, contact with your authorized dealer within 24 hours.
Attention: it requires a lapse of minimum 2 hours after any
transportation before you start operating your cooler. If the cooler has
remained in an environment where the temperature was below 0°C for a long
period, allow for the compressor temperature to reach beyond +5°C before re-
operating the cooler.
PRECAUTIONS AND SAFETY INSTRUCTIONS BEFORE THE INITIAL START-UP
Your cooler must be plugged certainly in an earthed wall socket.
Before operating the cooler, ensure that the mains socket is checked for
proper earthing (grounding) and nominal voltage and frequency requirements by
the authorized service staff or a qualified electrician. If the supply cord is
damaged, it must be replaced by the manufacturer, or its authorized service or
a similarly qualified person in order to avoid any hazard.
Do not use multi socket and extension cable.
The main power supply to which the cooler is connected must have a leakage
current relay. The nominal voltage and frequency requirements for the body are
specified on the data plate. Never make any repairs or carry out maintenance
while the cooler is plugged in the mains socket. Do not position the cooler in
a place close to a source of strong heat or exposed to direct sunlight. Always
remember that the UV lights in the sunlight deteriorates products in the glass
door cooler. The appliance can be used in ambient temperature of max 32°C.
Unless otherwise stated, do not place your cooler to open areas where water
can leak in.
Do not wash with pressurized water or hose when cleaning the product and its
surroundings, use a wet cloth. Otherwise, the water which may intrude into the
electrical components of the product can cause electric shock and fire risk.
Do not place your products in highly humid placed and/or places subject to
corrosion.
Start the cooler on a level surface. Position in on the floor and make sure
that it is level using a bubble gauge. If the cooler is found to tilt in one
particular direction, please adjust the height of the corresponding leg until
it is level. Then please move the cooler to the location where it will be
used.
Do not relocate the cooler or move the cooler on its rollers while its loaded
with product. If cooler is empty, please do not push the cooler to pass over
cables or door frames, to avoid roller damages. Never push the cooler when the
pavement is uneven, having inclination, or there are stairs nearby. All the
components that produce heat are located at the bottom part of your cooler
except the models S56SC and S88SC. These models have the heat producing
components on the top.
Proper air circulation at this part is very important to ensure performance,
therefore while positioning the cooler, allow minimum 10cm of space from the
sides.
Canopy lamps of S56SC and S88SC can be replaced only by skilled persons.
Do not let children get into and play around the body. Keep the cooler key and
plastic bags covering the accessories and the manual in a safe place out of
reach of children. Do not place any explosives and flammables in the cooler
for safety reasons. Leave the top of the cooler free, so that hot air from
bottom can circulate effectively. This appliance can be used by children aged
from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way und
understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
PLEASE CHECK YOUR REFRIGERANT GAS TYPE FROM THE RATING LABEL: R134A, R600A,
R290 OR R744 (CO2)
Only for the models with R600A or R290 gas:
R600A/R290 gas is used in some models, explained in this instruction manual.
R600A/R290 is an environmentally friendly gas and used in appliances which
have effective cooling technology. This gas is flammable only under certain
conditions. You must follow up the following rules if you wish to get normal
operating conditions
WARNING:
- keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
- do not use mechanical devices or other means to accelerate the defrosting process.
- do not damage the refrigerant circuit.
- do not use electrical appliances inside the storage compartments of the appliance.
- in order to reduce flammability hazards, the installation of this appliance must only be carried out by a suitable qualified person.
Do not tangle with the device due to maintenance, repair or any other reasons other than authorized service. Plug off the device against any possible freezing or icing and leave for defrosting. Choose original components for all parts necessary for replacement on the product.
Only for models with R744 (CO2) gas:
WARNING: the refrigeration system is under high pressure. Do not tamper
with it. Contact qualified service personnel before servicing. Please ensure
to comply with local regulations.
Pressure
The symbol above means that the cooling system is under the high pressure and
your appliance was marked with a warning label which contains this symbol.
The cooler uses CO2 refrigerant that operates at high pressures. A high
pressures safety switch is used to protect the system from exceeding the
desired safety limit. When the pressure switch activates it cuts off the power
supply to the controller, which in turn shuts the complete cooler down. After
the system pressures comes back to the normal range, the pressure safety
switch is deactivated and the cooler starts to operate normal again.
If the supply cord is connected to the plug and the cooler does not operate (lamps are off, all electrical components are off), please unplug the cooler and call a qualified service technician who has experience with CO2 refrigerators and is authorized to work with CO2 refrigerators. Please do not try to repair the cooler by yourself.
TECHNICAL FEATURES
- Door
- Power compartment
- Shelf
- Adjustable height
- Interior ventilation fan
- Canopy
- Green light
- Thermostat setting knob
- Lighting switch
- Fan switch
- Interior lighting
- Thermometer
- Electronic thermostat (optional)
Technical features | 7464.0085 – 7464.0090 – 7464.0095 |
---|---|
Operating temperature | °C |
Climate Class |
Please see the name plate
Power| W
Voltage / Frequency| V/Hz
External dimensions| WxDxH (mm)| 595x650x2000
Internal dimensions| WxDxH (mm)| 490x447x1570
Max. shelf load (net)| Kg| 41
Values specified above are given according to standard values and can vary by optional features. Type label is located in the refrigerant part of the cabinet. Please see the back page of the guide for the type label sample.
Climate Classes
Class| Temperature °C| Relative humidity %| Dew
point °C
0| 20| 50| 9,3
1| 16| 80| 12,6
2| 22| 65| 15,2
3| 25| 60| 16,7
4| 30| 55| 20
5| 27| 70| 21,1
6| 40| 40| 23,9
7| 35| 75| 30
8| 23,9| 55| 14,3
ASSEMBLING SINGLE DOOR COOLER / THE INITIAL START-UP
Air circulation at the rear is required for the coolers to operate efficiently. Move the cooler backwards to place it properly. Allow a minimum 10cm of space from the sides and the rear in order to ensure proper air circulation. Leva the top of the cooler free. For models S88SC and S56SC, allow minimum 10cm of space from the rear and minimum 30cm of space from the sides for proper air circulation. Your cooler is now ready to plug in.
OPERATION
Avoid blocking air circulation inside the cooler, when loading the cooler with products. Otherwise undesired and extensive temperature variances may occur between the top and bottom compartments of the cooler.
-
Control panel:
The Control panel consists of the following components depending on the model: -
Greenlight (optional):
It is lit so long as the cooler is connected to the electric supply. -
Thermostat setting knob (optional):
It is used to regulate the internal temperature of your cooler.
Thermostat adjustment is the most optimum adjustment in products with a mechanical thermostats in factory defaults. It is recommended not to be replaced as long as it is not troubled with the internal product temperature. If you think that the product is not in desired temperature range you can make a thermostat adjustment.Thermostat setting must be done according to the features of the products to be preserved. Temperature setting can be done by means of turning the black thermostat knob on the control panel by the help of a coin or similar object. Turning the knob right decreases the internal temperature, whereas turning it left increases the internal temperature. Turning the knob left stops the compressor, which in turn stops the chilling process, although the electric current to the cooler is not cut off. -
Internal ventilation fan switch (optional):
It used to provide air circulation inside the cooler. -
Internal lighting switch (optional):
It is used to turn on or off the internal light of your cooler. If the light bulb does not function anymore, always unplug the cooler from the mains before replacing it. Pull up the lamp cover. Rotate the electric bulb 90 degrees, take it off and replace it with a new one. Always replace the starter whenever you replace the electric bulb.
Canopy lamps and inside lamps of S88SC and S56SC can be replaced only by skilled persons.
Dismantling the illuminated advertisement panel
If it ever requires dismantling the illuminated advertisement panel, do the
following:
The LEFT lid is screwed to the body and it is not possible to dismantle it
from the outside. Therefore do not try to remove it. Advertisement panel is
fixed to the RIGHT lid. Hold the right lid on the top and bottom sides and
pull it RIGHTWARDS. The right lid will slide on the upper and lower tracks
allowing the compartment to open. Once the compartment is open, carry out the
needed (replacing the florescent lamps) and close the compartment by pulling
the lid in the opposite direction.
Replacing the fluorescent lighting: (if your product has a fluorescent
lamp)
Before dismantling the lamp, always unplug your cooler. After dismantling the
lamp cover inside the cooler, remove the lamp and always replace it with a
lamp of the same features (length, power, etc.)
WARNING:
Your cooler can have a fluorescent lamp. If the fluorescent lamp doesn’t
illuminate or start blinking, please call technical service to repair it in a
short while. Please do not remain your cooler whit non-working lighting
system. Your cooler can have a LED illumination. If you face any problem with
LED illumination, never try to repair it yourself. Inform an authorized
service.
Mounting the shelves:
There are 5 shelves provided with the models 7464.0085, 7464.0090, 7464.0095,
D148, SC505TF; 3 with S240SC; 2 with S149 and S88SC; and 1 with S56SC. First
insert the uppermost shelf in the uppermost hooks in the body. Insert the
others correspondingly with the same method. Chilling process in the body
takes place through the internal air circulation. Therefore do not place the
shelves very close to one another.
For models SC505HP, SC505 STD, SC600, S650:
There are 5 shelves and 20 shelf supports shipped inside the cooler. Carry out
the following to mount the shelves.
- Pilasters are numbered to provide height adjustment between the shelves in line with the product requirements. Place the shelf supports into corresponding notches on the pilasters. For an easy placement, use a pair of pincers to grip the support ends.
- Lay down the four shelves on the cooler floor. (Make sure that the right-angled (90°) side is at the rear).
- Hold the uppermost shelf; tilt one side and place on the hooks on the corresponding supports.
- Do the same for the remaining shelves and mount them all.
Removing the pallet and inserting the feet
Your single door cooler has been delivered on a wooden pallet, screwed to the
body at four corners. Please carry out the following to detach the pallet
before the body is set in its final operation location:
- Cut the 4 cable ties fixing to pallet to the cooler chassis by the means of a hand tool (except to S56SC and S88SC).
- Use a wrench to loosen and remove the head screws on the front and rear corners that fix the pallet to the base (only for S56SC and S88SC).
- Carefully detach the pallet from the body base. Please find the feet of the cooler provided interior. Insert them in the screwed sockets at the bottom of the cooler and make the height adjustment.
Defrosting:
Your cooler is devised with an automatic defrosting system regulated by the
thermostat. Defrost water accumulates in the channel underneath the
evaporator; it is then carried to the drip tray by the help of a hose where it
evaporates.
You can speed up defrosting by means of placing a bowl of hot water underneath
the cooler (make sure that it is not boiled). After defrosting, clean the body
and make sure to wipe it out leaving no moist inside. Plug the body again and
reload the cooler after one hour.
CLEANING, MAINTENANCE AND TRANSPORTATION
To ensure higher efficiency, your cooler must be regularly cleaned. Never use
any cleaning agent that contains alcohol, scouring powder or powerful
solvents. Always remove the plug from the mains socket before cleaning the
cooler. Add two teaspoons of baking soda (bicarbonate of soda) in 1 liter
water and use the mixture to clean the cooler. Clean the outer part with a wet
cloth and then wipe it out.
Attention: never use any hot water, electrical heater, sharp tools or
similar things as they may ham the cooler.
Holidays/stop using for a while:
Do not unplug your cooler if you are going on a holiday or stop using it for a
short time. If you are going on a holiday or stop using the body for a long
time, unplug the cooler and empty it. After defrosting, clean the cooler and
wipe it out with a cloth. Leave the door open to prevent odour in the cooler.
Transporting your cooler:
Before relocating the body, unplug it from the mains socket, defrost it, wipe
the interior walls and floor with a damp cloth, place the plastic blockings
between the glass door and the body and carry it in the normal position as it
is used.
Attention: expansion gas (C-Pentane) is used in the insulation system of
the cooler. When you dispose the body, it requires observing the applicable
laws and rules of the country in which it is used. Cleaning / maintaining of
your cooler’s condenser must be done at least two times in a year by
authorized service.
TROUBLESHOOTING
If the cooler does not function:
- Check if the cooler is properly plugged in the mains socket.
- Check if there is electric current to the mains socket.
- Check if the fuse has blown out.
- Check if there is power failure.
If the cooler operates more frequently than desired:’
- Check if the door is opened very frequently or left open for a long time.
- Check if the thermostat is set to chill more than desired.
- Check if the compressor compartment is properly ventilated or compressor compartment needs cleaning.
If the cooler does not cool enough:
- Check the temperature setting.
- Check if the door is opened very frequently or left open for a long time.
- Check if the internal air circulation is interrupted by overloading.
- Cleaning/maintaining of condenser might not be done (please see Section 6).
If there is odour in the cooler:
- Check if odorous stuff is openly stored.
- Check if inside is properly cleaned.
After checking the above-mentioned points and carrying out the recommendations, if your cooler still functions unsatisfactorily, contact the nearest authorized service centre, informing your complaints as well as the model and serial number of your cooler.
FOR MODEL WITH ELECTRONIC CONTROL SYSTEM
Our models with electronic control are designed with purpose of minimizing the energy consumption, and for that purpose they are equipped with special control systems. Your product is not only with thermostat control, it is equipped with a control system having feature of self-learning. It is unfavourable to mount and dismount the magnetic door switches, motion sensor and other equipment by unauthorized people. Control system is set so that refreshments should be kept at 3°C. This temperature value is the plant set temperature so that you can get the optimum efficiency from the cabinet and the ideal temperature recommended by refreshment producers.
Operating mode of electronic control system
The most important feature of the system is the self-learning module. It can
sense conditions of the usage and when the selling point that the product is
placed, is open or closed and it can control the operation characteristics in
this direction. This features are provided by recording the properties as the
density of the people around the cooler, frequency of opening and closing of
the door of the apparatus, light level of the environment where the cooler is
inside, with the help of the sensors.
Features that can be controlled by the control system
Control unit can open the lights of the cooler when the selling point is open
and shuts off the lights when the selling point is closed. This feature shall
operate after finishing the learning period of the control system. The light
of the cooler shall be open until finishing the learning period. Please do not
try to close it by yourself.
Control unit can control the inside evaporator fan. When the door is opened,
inner fans are stopped. When the equipment is in stand-by mode, inner fan
operates and stops with certain intervals. Stand-by mode refers the night or
the hours that cooler is not used. When the door of the unit is open for more
than 2 minutes, control unit give signal. For this reason, it is normal to
have signal during the loading of the refreshment. When the loading is
finished, signal stops with closing of the door.
In stand-by mode control unit can lower the operation period of the compressor
to the minimum levels. Control unit applies defrost periods in certain
intervals and it stops cooler system completely. After defrost operation,
system turns normal condition again. If there is a cooling defect in your
cooler, control unit gives an alarm.
Operation steps
Start your cooler in morning hours and in working hours. It is important that
the energy should not shut down during 48 hours. Control unit shall start to
learn working hours of the place it is in, and the operation characteristics
of the cooler from the first day it operates. When the control unit can
identify a stabile characteristic under operating conditions, it starts to
control the cooler. This period is between 2 and 10 days. When the learning
mode is completed, control unit shall start stand-by mode after selling point
is closed and after 30 minutes it shall turn off its lights. The next day, 3
hours before the opening of the shop, it shall pass to normal operating
condition in order to keep the refreshments inside ready.
Important note:
Control unit shall compare the product using characteristic that is recorded
and taken as reference with variable using characteristic continuously. In
direction of periodic changes as seasonal changes and change of opening and
closing hours of the shop, it shall learn and modify the program according to
new conditions and control the cooler continuously. Absolutely do not close
the front part of the motion sensor otherwise cooler shall not sense the using
frequency of the cooler.
Operation and screen information:
COMPRESSOR (compressor light): if green light is on, it shows that
compressor is active.
FAN (fan light): if green light is on, it shows that inner fans are
active.
On screen of the control panel, symbols stated below can appear depending on
the type of the trouble that may be formed and cooling mode of the cooler.
- “USE” : your cooler is ready to use
- “ _” : your cooler is in stand-by mode
- “888” : your cooler is in protection against freezing mode
- “dO” : it shows that the door is open
- “dEF” : system is in defrost mode
- “rSF” : there is a problem at cooling system, contact your cooler maintenance
- “SLO” : cooler is shut down because the voltage is low
- “SHI” : cooler is shut down because the voltage is high
- “Pf1” : input problem, contact your cooler maintenance
ATTENTION:
The defrost button can be used to set the cooler manually on defrost mode
which will last for 10 minutes.
- PIR (motion detector)
- Set button
- Compressor LED
- Fan LED
- Perishable LED**
- Motion LED
- Up button*
- Defrost button
- Display
- Down button*
- Configuration port*
these buttons are for service use only. This LED has no function on this cooler
FOR CAREL ECOBOX AND CAREL ENERGY SAVING CONTROLLED MODELS
Control unit flashes for a few seconds in order to check if all connections
are made correctly when the cooler is plugged in. This is normal, then the
display will indicate current temperature. Set temperature has been adjusted
to keep your beverages at optimum temperature, please do not attempt to change
the settings.
LIGHT: pushing at least 5 seconds the keypad, the light status will be toggled. Pushing the keypad, and before than the light status will be toggle, the display will show “On” or “OFF” in order to warn how the light status is going to change.
DAY/NIGHT MODE: the thermostat changes its mode automatically. If the door is continuously closed for more than 4 hours, the thermostat mode will be night and the lights of the cooler will be off. Lights can be on/off pushing the light button. If the door is opened at the night mode, the mode will be day. At the night mode your cooler consumes less energy. If you want to change the mode to the night you must push the day/night button. After 60 seconds from the pushing the mode will be night.
ECO MODE: pushing the keypad at least 3 seconds the ECO mode will toggle (if ECO mode is running then it will end, if ECO mode is waiting then it will start). Pushing the keypad, before then the ECO mode will toggle, the display will show “ECO” mode will toggle, the display will show “ECO” (Economy) or “nor” (normal) in order to warn how the functioning mode is going to change. If the thermostat is at the ECO mode, the cooler will consume less energy.
COMPLIANCE NORMS
Single door coolers described in this manual are manufactured and inspected in compliance with the
- TS EN ISO 23953-1
- TS EN ISO 23953-2
- TS EN 60335-2-89
- IEC 60335-2-89
- 2006/95/EC,
- 2004/108/EC