Combisteel 7072.11 series Vertical Glass Door Cooler Freezer User Manual

June 1, 2024
CombiSteel

Combisteel 7072.11 series Vertical Glass Door Cooler Freezer User Manual
Combisteel 7072.11 series Vertical Glass Door Cooler
Freezer

Dear customer,

This cooler and/or freezer, hereinafter referred to as “product”, which have successfully passed from quality control tests, have been produced with a big passion. To increase efficiency of your product, before using it we strongly recommend you;

  • To read the whole guide
  • Keep the guide as a source
  • To use the product according to guide instructions.

We want to remind that, we will be not responsible for the damages that depends on the incorrect usage or instruction disobedience.
For damage and information issues, please contact your local dealer.
The product will also be out of warranty, if someone other than authorized service interferes the product directly.
The aim of this products is keeping the beverages and foods cold.
We will also be not responsible if you run the product out of this purpose.

Thank you for preferring us and for your trust.

About the product

  • The operating temperature range of the cooler is between +1 and +10 degrees. The cooler you bought works between -1 and +4 degrees.
  • The operating temperature range of the freezer is between -18 and -23 degrees.
  • The product does not contain Asbestos, formaldehyde, cadmium and CFC materials
  • Compressor oil is based on none PCB and PCT.
  • The refrigerant gas is R600a or R290a, which is proper for KYOTO protocol.
  • This device is also proper for WEEE (Waste Electric and Electronic Equipment) regulations


THIS PRODUCT

Is respectful to environment and has been produced in modern plants

TECHNICAL FEATURES OF THE PRODUCT

TECHNICAL FEATURES| 7072.1100| 7072.1110| 7072.1120| 7072.1130| 7072.1135| 7072.1140
---|---|---|---|---|---|---
Gross volume| 550 LT| 1200 LT| 1555 LT| 1850 LT| 550 LT| 1210 LT
Net volume| 550 LT| 1200 LT| 1432 LT| 1630 LT| 500 LT| 1115 LT
Internal dimensions (WDH)| 544x636x 1594| 1184x636x 1594| 1534x636x 1594| 1824x636x 1594| 544x636x 1594| 1184x636x 1594
External dimensions (WDH)| 630x840x 2082| 1270x792x 2082| 1620x792x 2082| 1910x792x 2082| 666x800x 2082| 1306x841x 2082
Packaged External dimensions (WDH)| 661x830x 2089| 1303x783x 2089| 1653x783x 2089| 1948x783x 2089| 766x860x 2252| 1335x841x 2089
Area of projection view| 0,53 m²| 0,95 m²| 1,28 m²| 1,5 m²| 0,53 m²| 1,1 m²
Gross weight| 120| 212| 250| 310| 160| 235
Net weight| 108| 191| 225| 300| 150| 223
Operating temperature| -1°C/+4°C| -1°C/+4°C| -1°C/+4°C| -1°C/+4°C| -18°C/-23°C –| – 18°C/-23°C
Environment temperature| +16°C/+30°C| +16°C/+30°C| +16°C/+30°C| +16°C/+30°C| +16°C/+30°C| +16°C/+30°C

For commercial types, energy consumption tests are done according to the standards. Technical features are specified on the labels. Combisteel BV reserves all the rights for changing technical features of the products, without any kind of declaration.

Attention

The products that shown in this guide, are designed and produced according to National and International security norms. For safe and secure usage, following issues must be considered.

  • Check the socket, whether it is suitable or not. A grounded socket is must.
  • Make sure your structure wiring. Do not use sockets that are not fixed. Extension cable and multiple sockets are not advised. If it is an obligation, beware of voltage and cable diameter.
  • If the electrical connection is damaged, the replacement must be done by authorized Combisteel service.
  • While running, if you have a hesitation concerning electrical connection, call the authorized service.
  • When unplugging, hold the knob of the socket, never hang from cable.
  • External covers must not be removed. Otherwise, dangerous parts and sections will be accessible.
  • Never use pressured water. It may cause damages in electrical parts.
  • A defection may come from the product’s
  • electrical system or building electrical installation. For both, do not intervene to product directly. Unplug the cord, call the nearest service.
  • Never plug and run a damaged product (like a transport damage). Please contact to service.
  • Consider the maximum loading capacity. Do not pass the loading line.
  • Replacement of electrical parts must be done by authorized service.
  • Keep package materials somewhere, that none-adults can reach.
  • Package items (nylon, Styrofoam etc.) may be dangerous for nonadults or children.
  • For children and non-adult person usage, viewer discretion is advice.
  • For interior or exterior cabinet, always use materials that producer advise to use.
  • If an intervention is need, please contact to authorized service.
  • Never carry or move your product while it is plugged. Mending or maintenance must be prevented.
  • Obey the locate rules. To not to obey shutters and grids locations, may cause fires.

Instruction for carrying

  1. If possible, carry the cooler with a forklift or a hand lift
    Instruction Carrying

  2. If you have a no lift, carry the cooler with enough person in a stable position.
    Instruction Carrying

  3. While carrying the cooler always use gloves
    Instruction Carrying

  4. While carrying the cooler, just handle from wooden pallet. Never use front or back protection wire
    Instruction Carrying

Note Icon
NEVER LIE THE PRODUCT ON SIDE

Instruction for installation

  1. To remove the pallet, cut the plastic clamps
    Plastic Clamps

  2. At least three man should lower the cooler, as shown in the picture
    Shown Picture

  3. Make a stable pushing. Between cooler and wall, there must be min 15 cm gap
    Stable Pushing

  4. After allocated the cool should wait for three hours. In this moment, compressor oil will be balanced. Than you can plug it, the first run must be when te cooler is empty.

Assembly of the product

  • The protective film should be removed (if it exists)
  • By using adjustable feet, make the product stable. Avoid gaps, prevent vibration.
  • Compressor group air inlet must not be prevented. This is the most important issue. Allocate your product that it will be parallel to the ground, no aim is required. Adjustable feet and rollers must touch the base. The distance between compressor group and wall is important. More distance, provides increasing performance. For that reason, at least 15 cm gap is required.
  • After transport of the product, before operating it, you should wait for four hours.
  • The first running must be done when the product is empty. Loading can be done after this period.
  • Connection of the product must be checked by experienced electrician. The fuse height must be 170 cm
  • For fault current, electric connection must be supported with 30 mA fuse.
  • The product must be also provided with the nearest ground.

Usage for the product

The temperature of the product is calibrated for the most proper conditions. The operating temperature can be adjusted from the digital thermostat. We advise you to keep them with default factory value. The internal temperature of the refrigerator can be adjusted between +1 and +10 degrees. The internal temperature of the freezer can be adjusted between -18 and -23 degrees. Digital thermostats have default factory values, and no need adjustment. Thermostats may have many programs within (eco mode, night mode etc.) If you have a problem with your product, please contact your dealer. Failure codes are listed in failure section. If you get any of these, stop the alarm of the thermostat and inform your dealer.

All models, except 7072.1100, have automatic defrost. Although your products prevents snowing, high humidity and temperature may cause snowing rate. Operating time depends on snowing, which also means energy consumption will rise. At this position, stop the working and clean the snow.

DO NOT FORGET! UNFROZEN EVAPORATOR WILL GIVE THE HIGH EFFICIENCY.

Before calling service & cleaning

Before calling service

Failure Possible solution Result
The product is not working. There is only fans noise or there is no noise
Check the plug and fuse. There may not be electric. It will work again, when

the temperature is proper. Plug it properly
Internal temperature is high| External temperature may be high or thermostat adjustment may be wrong. The distance between product and wall may be poor. Extremely exposed to external wings. Condenser fins may need to be clean.| Decrease the external temperature or move the product where the temperature is low. Open frontside of the air shutter. Prevent snow.
Internal temperature is low| Wrong thermostat adjustment.| Adjust the thermostat
Cooling lamps are not lighting or just one is lighting| Lamps may be closed. Lamps or starter may be broken.| Open the lamps. Request for broken parts
So much liquid or on the glass or inside of product| Water drain hole may be closed. External humidity may be over 65%.| Clean the water drain hole. Keep the product somewhere, where the humidity is less.
Bad smells from bottom side| Water drain pan should be cleaned.| Water drain pan should be cleaned.

Internal cleaning
Remove beverages. Wait for the internal temperature that it will be same with environment temperature. For cleaning and maintenance use a protection glove, this will protect you from injuries. Remove the accessories. Use a soft cotton linen with warm soap water .For drying, use cotton based linen. For first operating, wait for two hours. Than you can reload your beverages.

External cleaning
Use a cotton base linen with warm water. Avoid water from front control panel or lighting departments. For door gasket, just use clean water with soap.

Combisteel Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals