Chocan ZR150SR Household Inter Connected Photoelectric Smoke Alarm User Manual

July 23, 2024
Chocan

Chocan ZR150SR Household Inter Connected Photoelectric Smoke Alarm User Manual

Thanks for choosing 34150 household inter-connected photoelectric smoke alarm. In order to ensure your personal and system safety and realize the best product performance, please read this manual carefully and completely before installing, using or repairing this device, and the Warnings and Notes in this manual should be paid special attention to.

Product Description

The 34150 household inter-connected photoelectric smoke alarm (alarm) detects fire by sensing smoke. When smoke in the room reaches a certain concentration, the alarm will send out sound and light warning alarm. This alarm is applicable for residential houses.
Standard implemented

Product Features

  • Single-light source detection, free from false alarm due to dusts, insects or moisture
  • Professional maze design, quick sense of fire
  • Max 24 devices can be inter-connected
  • Fire-retardant plastic case with glossy surface treatment
  • Dismantle-free cover design for cleaning
  • Blind twist design +3M double-sided glue quick installation

Technical Parameters

Model 34150 (model: ZR150SR)
Operating Voltage DC3V (CR123A)
Battery Capacity 1600mAh
Wireless Protocol 868.3MHz
Average Quiescent Current < 20uA
Alarming Mode Sound + light
Alarming Sound Level ≥85dB (at 3m)
Operating Humidity ≤95%RH (non-condensation)
Battery Life 5 years (typical value)
Operating Temperature -10°C~55°C
Installation Ceiling-mounted (screwing or 3M gum)
Size (LWH) 76mm76mm28.5mm
Standard EN 14604:2005+AC:2008

Product Installation

Fig.1

  • Place the mounting plate on the desired installation location and mark where the holes should be drilled.
  • Drill two holes with a diameter of 4 millimeters. (The distance between them is 42 millimeters)
  • Push the plastic plugs into the holes.
  • Insert the screws into the mounting plate, and tighten them firmly into the plugs.
  • Fasten the smoke alarm on the mounting plate by twisting clockwise.
  • Fasten the smoke alarm when the holes on the mounting plate and smoke alarm are aligned.
  • Press the test button to check whether the smoke alarm operation normally, the smoke alarm is abnormal and can not be used if no sound.

Fig.2

  • 3M gum to fix the mounting plate onto the ceiling
  • Mount the alarm onto the mounting plate
  • Twist clockwise the alarm to lock the alarm onto the mounting plate

Notes (fig.3):

The smoke alarm should be installed in the middle of the room ceiling;
The smoke alarm should only be installed indoor and at least one alarm in each room;
The smoke alarm should be at least 150cm away from lights, exhaust fan, air conditioner and air inlet/outlet;
Do not install the alarm in bathroom or those places with water drops;

Inter-connecting Instruction

  1. Each 34150 alarm has one RF module embedded, which enables you to connect two or more same alarms so as to create a inter-connected network. When one alarm alarms, all inter-connected alarms will alarm at the same time. So when you have more than one 34150 alarm, and you need to create a local network, then please follow below steps:
  2. Power on the alarm (beep once after powered on successfully) and long-press the test button more than 5 seconds, wait till the red LED indicator flashes consecutively, which means the alarm is under wireless matching mode;
  3. Repeat step 1) on another 34150 alarm;
  4. Short-press the test button on one of the 34150 alarms to connect the network. After connection is successful, the red LED indicator will stop flashing on another 34150 alarm. The short-pressed alarm will still in match mode, and LED indicator flash slower than before. Please complete steps 1), 2) and 3) in 1 minute.
  5. If you want to connect a third smoke alarm, please repeat steps 1), 2) and 3). Max 24 alarms can be connected in one network.
  6. To disconnect the alarms: repeat step 1), and then long-press test button, wait till beep once, it means the disconnection is completed.

Note: When two new alarms have been networked, a new network will be established. Alarms in two different networks cannot be networked together.
If there is no beep after powered on, please remove the battery, short-press the button, then install the battery in.
After powered successfully, the interconnection is effective within 2 hours. It needs to be powered again for operation if the time exceeds 2 hours.

Indicator States Instruction

Normal Operating State
Under normal operating state, the red indicator flashes one time per 40 seconds

Alarming State
When smoke concentration reaches alarming point, the red indicator flashes consecutively and the alarm sends out beeping alarm.
Testing State
Short-pressing the test button, the red indicator will flash consecutively, the alarm will send out three beeping sound, a period later, it will automatically stop.
Low Power Failure State
Under low power failure state, the red indicator flash once per 40 seconds, at the same time, the alarm will beep once.
Device Failure State
The red indicator flashes twice per 40 seconds, and the alarm beeps twice per 40 seconds.
RF Paired State
Red LED will slowly flash when the alarm powered on and long-press the test button more than 5 seconds.
RF Not Paired State
Red LED will quickly flash when the alarm powered on and long-press the test button more than 5 seconds
RF Pairing Failure State
The alarm will generate two “chirps” with the red LED flashes twice after paired failure.
Hush State
When the alarm is at alarming state, users can short-press the test button to make the  alarm enter hush state, then the alarm will not send out sound alarm, 9 minutes later, if the smoke concentration is still above the alarming point, the alarm will start to send out sound and light alarm again.
Notes: The hush state will not mitigate the fire risk. When any alarm is initiated, please do check your house for any potential fire risk. Please handle the used battery properly to avoid environmental pollution.

Trouble Shooting

Failure Possible Reason(s) Measure(s)
Alarm immediately upon power on A lot of smoke indoor Power on the device

again after smoke removed
| Internal circuit damaged| Return the device for repair
Beep one time per 40s after powered on| Low battery voltage| Replace one battery of same model
Beep twice per 40s after powered on| Internal circuit damaged| Return the device for repair
No alarm when testing| Battery installed incorrectly| Check and install the bat- tery again (pay attention to polarity)
| Low battery voltage| Replace one battery of same model
| Internal circuit damaged| Return the device for repair
No sound or low sound of buzzer| Low battery voltage| Replace one battery of same model
| Buzzer misplaced| Return the device for repair

Care and maintenance

  1. After the alarm is installed and put into use, press the test button to test the detector every week.
  2. Clear smoke alarms: clean the smoke alarms at least once a year to keep them clean from the accumulated dust.

Caution:
Please do not smear your smoke alarm with paint, coating etc., which may obstruct the smoke inlet to affect the alarm work normally.
Do not use solvents or detergents to clean your smoke alarm. The solvents or detergents permeate the alarm may lead to sensor mishaps or circuit damage, can clean with cotton cloth or sponge.

Battery Replacement (fig.4)

When the alarm displays the battery low-voltage fault, please replace the battery of same model in time, press the test button after replacing the battery, the alarm will send out the sound and light for the successful replacement.

  1. Detach the smoke alarm from the mounting plate by twisting counterclockwise.
  2. Replace the battery with an new battery, please match the correct polarity marking.
  3. Press the button to test the alarm, then lock the alarm onto the mounting plate by twisting clockwise.

Contact us

Thanks for choosing our smoke alarm. This smoke alarm is under our company warranty. For any quality issue or device failure, please contact us. We are dedicated in providing excellent service and quick response!

DoP N° : 34150-CPR-0524
1008-CPR-MC 69265752
Model : ZR150SR
Ref.: 34150
EN 14604:2005/AC:2008
Use 3V Lithium Battery type : CR123A

Read User Manual Online (PDF format)