FLINQ FQC8242 CO2 Meter User Manual

June 5, 2024
FlinQ

FLINQ FQC8242 CO2 Meter User Manual

Thanks for purchasing this Flin0 product! To ensure continuous operation and accuracy, please read these operating instructions carefully before use and save this manual for future use. To skip certain procedures may result in incorrect reading and use. We hope that you will enjoy using your new product! If by any chance the item is damaged, defective or broken, you are covered with warranty! Please do not hesitate to contact us for any questions, concerns or suggestions at the email address as mentioned in this manual. We deserve the right to make technical and design modifications in the course of continuous product development. Read and follow the instructions contained in this manual carefully. Keep these instructions at a safe place for future reference.

Safety Information:

Please read this manual thoroughly before using the product! Keep it in hand for future reference. Warnings alert the user to potential serious outcomes, such as injury or adverse events to the user. Cautions alert the user to exercise care necessary for the safe and effective use of the product. Notes contain important information that may be overlooked or missed. This product can be used indoors (see below for more info). This appliance may be used (but not installed) by children aged 12 and over, and by persons with reduced physical, sensory or mental capacities or a lack of sufficient experience and/or knowledge, provided they are supervised or have been trained in the safe use of the appliance and understand the potential dangers. Cleaning and maintenance must not be carried out by children without supervision. Children must not be allowed to play with the appliance. Keep the packaging material away from children. There is a risk of suffocation! Do not allow unsupervised children to clean or maintain this device. • WARNING! Do not leave packaging material lying around carelessly. This may become dangerous playing material for children. Risk of suffocation! • DANGER due to swallowing small parts. Keep these away from children. Risk of suffocation!

Avoid danger to life by electric shock:

  • Do not operate the unit with a damaged power line or damaged power plug. ATTENTION! Damaged power lines represent danger to life by electric shock.
  • Check the power lines regularly for damages and aging. If the power line is damaged, it must be re- placed by the manufacturer, his / her representative or a similarly qualified person in order to avoid safety hazards.
  • Protect the power line against sharp edges, mechanical strain and hot surfaces.
  • Do not switch on the unit if you notice visible damages (e.g. tears or cracks) or if you assume that the unit is damaged (e.g. after having fallen down).

NOTE/WARNINGS:

  • Do not open the device yourself.
  • This device is not a TOY, Keep away from children!
  • Do not use with appliances that could cause any fire in unattended use (like irons etc.).
  • Any other use as the intended way for this device is not validated for any warranty or liability. •This device is only used for domestic and private use!
  • Do not use the device excessively and do not store them under heavy pressure. The device is not resistant to heat and water. •Avoid rain, dampness or contact with other liquids

Speciation


This product is an air CO2 product. It is developed for air quality monitoring. Read and follow the instructions contained in this manual carefully. Keep these instructions at a safe place for future reference. Dispose of packaging material to local applicable regulations. The operating life of the product will be less if the ambient temperature is higher than 45°C or lower than -io°C.

MAIN USE CAUTIONS BEFORE FIRST USE

NOTE:
  • Make sure the cables cannot cause a trip hazard.
  • This device is intended for inside use.
  • This is not a TOY, keep away from small children below 12 years.
  • Do not open or disassemble the device yourself, this will void the warranty at all times.
  • Do not disassemble, repair or modify the product by yourself as this may result into an electric shock.
  • The led source is not replaceable. •If the cable is damaged or broken please contact your seller for correct replacement by the manufacturer only.
  • Do not stand, sit on, jump or throw with the device at all times. •Do not throw this product in the air to avoid damage caused by falling.
  • Only use the device for its intended designed use.
  • Take good care of the product and clean it regularly.
  • Never touch the plug contacts with sharp or metal objects.
  • Use only the original supply and original accessories.
  • Protect the device from special liquids and vapors

NOTE

  • Please note that the power port of the device should not have water infiltration. Otherwise, it will cause a product failure. Co not charge or store the product in a place below oC or above 4o C, otherwise the product performance will be reduced.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

Do not install/use/throw near a gas, fan’s, aircon’s, electric radiator, fireplace, candles, air humidifiers, purifiers or other sources with a similar heat or explosion/flammable liquids and gasses. This product is to be used only for private or office non-commercial professional use. Use only in dry rooms and do not use it in damp environments. Only use this product under moderate climates. Do not place the product near interference fields like computers, TV’s etc. Damage from this housing/ device can cause explosion and/or fire. Under extreme conditions the battery cells can cause leaking. If that fluid touches the skin then please clean directly with water and soap. If within the eyes then clean with water for at least 3.0 minutes and consult a doctor.

Do not use near or in gas stations.
Do not staple, nail, or hook the power cable. Never touch the plug contacts with sharp or metal objects.
Do not hang the device only by the electric cables.
An electric product is not a toy! To avoid the risk of fire, burns, injuries or electric shock, the power cable should not be left within the reach of children.
Do not use the product outside its intended use and do not modify or open it.
Do not hang ornaments or other objects on the device cables.
Do not close windows and doors on the power cord so as not to damage the insulation.
Do not cover the product with a material (paper, cloth, etc.) that is not part of the product when in use. Read and follow all instructions that are indicated on the product or supplied with it. Keep this manual for future reference.

Product general description:

  1. Mode button

  2. Left button

  3. Right button

  4. USB Charging/Power connection

  5. Air Vents (do not cover it at all times)

  6. Temperature sensor (do not cover it at all times)

  7. Air Quality Detector (do not cover it at all times)

  8. Illuminated screen display with CO2 PPM, Temperature and Humidity battery / warning /alarm status

  9. CO2 Particle concentration in PPM value >» Carbon Dioxide Concentration measured in parts per million.

  10. Alarm function ON/OFF >» When the alarm icon is not displayed the alarm will not work.

  11. Battery charge level >>> Green = Fully charged, Orange = Almost empty and Red = Empty or during charge

  12. CO2 AOI Indicator color light >» Green = Good/Healthy, Orange = Fair/Normal and Red = Unhealthy/Very Poor.

  13. Temperature value >» in Celsius degree and for good health a 18-22 degree is required.

  14. Ambient humidity >» for good health inside a 40-60% humidity is required. Before using this product: Don’ t let children play with the appliance; supervise children using or maintaining the appliance. If you are wearing a pacemaker or other electronic medical implants device, you should seek your doctor’s advice

before using this product.

Use only manufacturer’s recommended attachments as described in this manual, misuse or use of any accessory or attachment other than those recommended, may present a risk of personal injury. Keep the appliance and accessories away from hot surface. Do not block the appliances openings or hinder airflow, keep openings free of any objects including dust, clothing, fingers (and all other parts of the body). Particularly keep hair away from openings and moving parts if possible.

Warning:

Any operations that oppose to description in this user manual may lead to harm to human or this product device.

Charging the device:

FULLY CHARGE THIS DEVICE BEFORE THE FIRST USE! a. Insert the USB connection jack end of the charging cable for charging to the charge input port of the device and connect the (optional, not included) power adapter itself to the mains power output socket.

NOTE:

You can use any USB smartphone/tablet power adapter with a minimum output from 5v DC / iA-2A (2000mA max), maximum charging is 3-4 hours depending on adapter model/type that is used. 2. RED light display battery status = it is charging. 3. GREEN led light display battery status = It is fully charged. 4. Remove charging cable from the device when ready and disconnect the adapter from the mains power socket. Use time wirelessly = 10-12 hours max. You can also use it in mains power supply and operational use at all times.

AG! explanation:

The amount of CO2 in indoor air is a measure of air exchange depending on the use of the space (i.e. the number of people present). of the space (i.e. the number of people present) and CO2 can easily be measured with a CO2 meter. The less air exchange, the greater the amount of CO2 in the indoor air. Since Covid-ig is, like CO2, part of the exhaled air, the monitoring of the CO2 concentration in a room can be used as a measure for the quality of the air concentration in space can be used as a measure of risk for Covid-ig contamination. In general, it is important to keep the CO2 concentration in a room as low as possible at all times, below lower than goo ppm. High CO2 levels mean that the air is not being sufficiently refreshed. The less the air is changed, the more potential virus particles accumulate in the indoor air. Keep track of the number and duration of exceedances (more than goo ppm CO2) as little as possible and look for solutions: – Open windows and doors further or open more windows and doors – Check whether the ventilation system is working properly and, if necessary, increase its setting – Limit the number of people in the room, have fewer people in the room at the same time Note that it is not the case that with low levels of CO2 in the room, there is no risk of infection for SARS-CoV-2 exists. Indeed, the number of people present may be low, so that the enrichment of CO2 is limited and remains below goo ppm while still allowing infectious particles into the room. In a large-volume room, the CO2 concentration may also be low because of dilution yet there is still a risk of infection. Therefore continue to ventilate and air even when few people are present in an area, before, during and after their presence.

Note:

This device must not be used as a warning device for dangerously high concentrations (like industrial safety monitoring) and it is not suitable for medical institutions, certification or test measurements.

Air quality indicators:

The detector shows the current air quality level on the display with colors and smileys what the current air quality level is.
The linked values are shown in the table below.

The air classification index is divided into the following warning bars on the screen below the smileys:

Green = Good/Healthy air Level i. Green 400-57oppm Level 2. Green 57o-74oppm Level3. Green 74o-gooppm
Orange = Fair/Normal > but ventilation by open windows/doors is suggested. Level i. Orange goi-nooppm Leve12. Orange noo-3.3ooppm Level3. Orange 3.3oo-3.5ooppm
Red = Unhealthy/Very Poor > open all windows and doors to i00% refresh the inner space/room. Level i. Red 15o1-25ooppm Leve12. Red 2500-35ooppm Level3. Red 35oo-5000ppm

RE-CALIBRATION/RESET:

RESET: When power OFF and ON the software will be RESET each time. RE- CALIBRATION CO2 SENSOR: Ageing of the sensor may cause “drift” (=a small, constant change in the measurement results of the same device in the same conditions) causing the sensor to no longer correctly. Therefore it is important that the sensor is calibrated regularly (=adjusting the sensor so it measures correctly again).

The CO2 sensor is extensively tested and calibrated at the factory. The first time it is used you do not have to calibrate it yourself. To ensure reliable measurements, it is recommended after prolonged use (>i year) to calibrate the device again. Perform the calibration outdoors (do not place outdoors when raining) or in a well-ventilated place. When the CO2 value has dropped to 5 413 PPM (outside air is around 400PPM), there is no direct sunlight or other CO2 source nearby you can start calibrating. Please try to avoid perfumes, paints, air fresheners, cigarette smoke, alcohol, chemical substances and so on while carrying out measurements since these can lead to incorrect measuring results Press and hold the LEFT button until CO2 value starts blinking. The device will now execute the calibration process which takes about 5 minutes. The calibration will stop automatically and will be finished when the unit stops blinking. Attention: do not switch off the device during the calibration!

Batteries warning note:

New batteries must be recharged and discharged 3 – 5 times before their full function use time is released. Charge indoors only at room temperature and only under supervision during daytime. Disconnect from the charger when the battery is fully charged, as overcharging can shorten battery life. Lithium batteries should only be charged with constant current/constant voltage (CC/CV). When not in usage, the charge in a fully charged battery slowly disappears. Do not place the product near a heat source or expose it to direct sunlight, dust, moisture, rain or mechanical impact. Try to keep the battery temperature between o°C and 45°C at all times. If the battery is too hot ortoo cold, the product may not work temporarily, even if it is fully charged. Do not attempt to charge the device when the battery is damaged. Never insert metal objects in any opening of the (USB) charging port. The rechargeable battery is built into the device and cannot be replaced. Do not throw the battery into the fire, otherwise it may explode. Batteries may also explode if being damaged, please handle and disposal it according to local conditions and regulations. After 3 months long storage, need to completely discharged and recharge for at least 8o%. The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not disassemble, short contacts, heat above 6o°C (140°F), or incinerate. Keep away from children. Do not disassemble and do not dispose of in fire.

WASTE ELETRICAL & ELECTRONIC EQUIPMENT Disposal Information

This symbol means the product must not be discarded with the general household waste.There is a separate collection system for these products. ■Ii

the waste electrical and electronic equipment directive zolz/ig/EU: This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household user should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. Do not dispose of batteries in your household waste. Dispose of this product and/or batteries by taking them to your local recycling store or station for free, contact your local government office for more details. If possible please dispose the batteries separately as stated by law and let it be recycled separately or give it at your local sales store/distributor/dealer that dispose it correctly and free of charge at all times. By recycling, reusing the materials or other forms of utilizing old devices/batteries, you are making an important contribution to protecting our environment and use way. ri g

Warranty

The warranty begins on the date of purchase and expires after 24 months. The warranty period is considered to have started three months after the date of manufacturing indicated on the product or as derived from the serial number of the product. If any defect due to faulty materials and/or workmanship occurs within the warranty period contact us immediately, we will make arrangements for service. Where a repair is not possible or is deemed uneconomical we may agree to replace the product. Replacement will be offered at our discretion and the warranty will continue from the date of original purchase. The warranty applies provided the product has been handled properly for its intended use and in accordance with the operating instructions. Support, warranty and questions information: info®flinqproducts.n1 This product is designed, produced and tested in accordance with the strictest European safety directive’s and test standards.