PHILIPS 8465166 UVC Disinfection Batten
UVC Disinfection Batten
The UV-C batten is designed for the disinfection of surfaces and is suitable for a wide range of applications. The UV-C batten provides universal UV-C irradiance with homogenous distribution. Its disinfection capability is based on wattage used and a specific exposure time for a given distance from that surface. No person should be present at the time of usage, due to high risk of harm to eyes and skin. The performance is enhanced by a highly-reflective and durable aluminum body, which improves its efficacy even further and directs the UV-C light to the to-be-irradiated surfaces. The lamp holders and end caps are protected against UV-C thanks to dedicated shielding. There is a 1- and 2-lamp version available, for both the bare batten and reflector batten. This offers even a greater flexibility.
Benefits
- UVC Disinfection Batten
- The UV-C batten is designed for the disinfection of surfaces and is suitable for a wide range of applications. The UV-C batten provides universal UV-C irradiance with homogenous distribution. Its disinfection capability is based on wattage used and a specific exposure time for a given distance from that surface. No person should be present at the time of usage, due to high risk of harm to eyes and skin. The performance is enhanced by a highly-reflective and durable aluminum body, which improves its efficacy even further and directs the UV-C light to the to-be-irradiated surfaces. The lamp holders and end caps are protected against UV-C thanks to dedicated shielding.
- There is a 1- and 2-lamp version available, for both the bare batten and reflector batten. This offers even a greater flexibility.
Features
- Lamp configurations possible: 1-lamp or 2-lamps version.
- Available with or without reflectors.
- Philips T8 TUV lamp included: 36W.
- Shortwave UV radiation peak at 253.7 nm (UVC).
- High reflective aluminum housing for better reflectivity and performance.
- Various mounting option
- Complies with all applicable regulations and standards
Application
- Retail: Keep shopping carts, shelves and counters free from contamination
- Schools: Disinfect classroom walls, floors, desks and surfaces
- Banking: Disinfect counters, cash machines and work surfaces
- Food outlets: Eliminate bacteria on preparation surfaces and equipment
- Hair and beauty salons: Disinfect client rooms, operating floor, mirrors, chairs surfaces, and other sensitive areas
- Offices: Neutralize work rooms, meeting spaces and corridors
- Hospitality: Disinfect guest rooms, reception areas and health facilities
- Washrooms: Disinfect vanity units, basins and mirrors
Warnings and Safety
- DANGER: Risk Group 3 UV product. Like any disinfection system, UV-C devices must be installed and used in the correct way. Direct exposure to UV-C can be dangerous and result in a sunburn-like reaction to the skin and serious damage to the cornea. As UV-C is invisible to the eye, the UV-C batten must be installed with adequate safeguards to ensure that the UV-C batten can be operated in a safe way. The UV-C battens are only to be used as components in a system that consists of adequate safeguards such as, but not limited to, those indicated in the mounting instruction and/or user manual.
- Philips UV-C products must only be sold through qualified partners and installed by professionals according to our stringent safety and legal requirements. Our UV-C products are not meant to be used in applications or activities which may cause and/or lead to death, personal injury and/or damage to the environment.
- The UV-C battens’ effectiveness in the inactivation of certain viruses, bacteria, protozoa, fungi or other harmful micro-organisms is as described under “Benefits”. Signify and its group of companies do not promise or warrant that the use of UV-C battens will protect or prevent any user from infection and/or contamination with any harmful micro-organisms, illness or disease. The UV-C battens are not approved for, are not intended and must not be used as medical devices, as such term may be defined under the applicable laws of the countries in which the battens are made available. In addition to and without limitation of any exclusions or limitations of liability of Signify and its group of companies as set forth in any agreement for sale, distribution or otherwise making available of the UV-C battens, Signify and its group of companies shall have no responsibility or liability whatsoever for any claim or damage that may arise from or relate to any use of the UV-C battens outside of their intended use or contrary to their installation and operation instructions, each as described under “Application”, the user manual and/or the mounting instruction.
Versions
UVC Disinfection Batten
Application conditions
Ambient temperature range| -10 to +45 °C
Suitable for random switching| No
|
Approval and application|
Mech. impact protection code| IK02
Ingress protection code| IP20
|
Controls and dimming|
Dimmable| No
|
Operating and electrical|
Inrush current| 18 A
Inrush time| 0.25 ms
Power Factor (Min)| 0.95
|
General information|
Cable| –
CE mark| CE mark
Protection class IEC| Safety class I (I)
Connection| SI
ENEC mark| –
Flammability mark| NO
Gear| HFP
Glow-wire test| 650/30
Number of gear units| 1 unit
Number of products on MCB of 16 A
type B
| 28
Optic type| No
EU RoHS compliant| Yes
Warranty period| 1 years
|
Initial performance (IEC compliant)|
Power consumption tolerance| +/-10%
|
Mechanical and housing|
Color| White and black
Housing Material| Steel
Optic material| Aluminum
Reflector material| Aluminum
Overall height| 80 mm
|
UV|
UV-C irradiance defined at 20cm| 57.6 µW/cm²
Operating and electrical
Order Code| Full Product Name| Input Frequency|
Input Voltage
---|---|---|---
911401524471| TMS160C 1X36W TUV SLV/6| 52 or 60 Hz| 222 to 240 V
911401524571| TMS160C 1X36W TUV SLV/6 R| 53 or 60 Hz| 223 to 240 V
911401524871| TMS160C 2X36W TUV SLV/6| 54 or 60 Hz| 224 to 240 V
911401524971| TMS160C 2X36W TUV SLV/6 R| 55 or 60 Hz| 225 to 240 V
General information
Initial performance (IEC compliant)
© 2021 Signify Holding All rights reserved. Signify does not give any
representation or warranty as to the accuracy or completeness of the
information included herein and shall not be liable for any action in reliance
thereon. The information presented in this document is not intended as any
commercial offer and does not form part of any quotation or contract, unless
otherwise agreed by Signify. All trademarks are owned by Signify Holding or
their respective owners.
www.lighting.philips.com
2021, December 9 – data subject to change
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>