ROLLEASE ACMEDA MTDCRF-CL-0.6-50 Automate ARC Cord Lift Motors Instruction Manual

June 5, 2024
ROLLEASE ACMEDA

MTDCRF-CL-0.6-50 Automate ARC Cord Lift Motors

AUTOMATETM
ARCTM CORD LIFT MOTORS

Part number MTDCRF-CL-0.6-50/MTDCRF-CL-0.6-50-A MT01-3001-069001

Description CL 0.6Nm Cord Lift Motor CL 0.8Nm Cord Lift Motor

433 MHZ BI-DIRECTIONAL

ELECTRONIC LIMIT

SELECTABLE RPM

FAVORITE POSITION

LEVEL CONTROL

AUTOMATETM | ARCTM Cord Lift motors enable motorized function of shades utilizing cord take up systems. The Leveling Control allows for precise positioning of individual or multiple shades ensuring perfect alignment every time. Additionally, a favorite position can be pre-set and recalled at any time.
FEATURES: · Smart Home Control · IOT Integration · Electronic Limits · 433 MHz Bi-Directional RF Communication · Leveling Control · 3 x Selectable Rpm · Favorite Position · Roller & Tilt Modes.

CL Motor_PRGM_GL_v1.0 DEC 2017

CONTENTS
1 ASSEMBLY 1.1 0.6 Nm Motor 1.2 0.8 Nm Motor 2 WIRING 2.1 Power Option 3 P1 BUTTON FUNCTIONS 3.1 Motor State Test 3.2 Motor Configuration Options 4 INITIAL SET-UP 4.1 Pair Motor with controller 4.2 Check motor direction 4.3 Set limits 5 ADJUSTING LIMITS 5.1 Adjust upper limit 5.2 Adjust lower limit 6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 6.1 Using motor P1 button 6.2 Using a pre-existing controller 7 FAVORITE POSITIONING 7.1 Set favorite position 7.2 Send shade to favorite position 7.3 Delete favorite position 8 ADJUSTING 0.8NM MOTOR SPEED 8.1 Increase or decrease 0.8Nm motor speed 9 TILT & ROLLER MODE 9.1 Enter tilt mode 9.2 Enter roller mode (Default) 10 SLEEP MODE 10.1 Enter sleep mode 10.2 Exit sleep mode 11 TROUBLESHOOTING
2 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

5 5 6 7 7 8 8 8 9 9 9 10 11 11 11 12 12 12 13 13 13 13 14 14 15 15 15 16 16 16 17
ROLLEASE ACMEDA

SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.

CAUTION
· Do not expose to moisture or extreme temperatures. · Do not allow children to play with this device. · Use or modification outside the scope of this instruction manual will void warranty. · Installation and programming to be performed by a suitably qualified installer. · For use within tubular blinds. · Ensure correct crown and drive adaptors are used for the intended system. · Keep antenna straight and clear from metal objects · Do not cut the antenna. · Use only Rollease Acmeda hardware. · Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. · Ensure torque and operating time is compatible with end application. · Do not expose the motor to water or install in humid or damp environments. · Motor is to be installed in horizontal application only. · Do not drill into motor body. · The routing of cable through walls shall be protected by isolating bushes or grommets. · Ensure power cable and aerial is clear and protected from moving parts. · If cable or power connector is damaged do not use.
Important safety instructions to be read prior to operation.
· It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product.
· Keep remote controls away from children. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep motor away from acid and alkali. · Do not force the motor drive. · Keep clear when in operation.

Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately.

5005833

3 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

1 ASSEMBLY 1.1 0.6 Nm Motor
The 0.6Nm Automate Cord Lift motor must be installed flush with the end cap.
Step 1. Secure the shaft adapter to the shaft with a grub
screw.
Step 2. Attach Headrail Adapters to the motor (2 each required).
Step 3. Attach the shaft with adapter to the Motor assembly.
Step 4. Insert Motor assembly into the headrail.
Ensure shaft adapter full engages motor drive recess.
Step 5. Ensure power cord and antenna extend freely from the
headrail. Anchor the Motor to the headrail.
4 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

1.2 0.8 Nm Motor
The 0.8Nm Automate Cord Lift motor can be installed at any position inside the aluminum extrusion.
Step 1. Secure the shaft adapter to the shaft with a grub
screw (2 assemblies required).
Step 2. Attach Headrail Adapters to the motor (2 each required).

Step 3. Attach the shaft with adapter to the Motor assembly.

Step 4. Insert Motor assembly into the headrail.
Ensure shaft adapter fully engages with the motor drive recess.
Step 5. Ensure power cord and antenna extend freely from
the headrail. Anchor the Motor to the headrail where desired.
5 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

2 WIRING
2.1 Power Option
Automate DC motors are powered from a 12V DC power source. AA Battery wands, re-chargeable battery packs and A/C Adapters are available, with a variety of quick connect extension cords. For centralized installations, power supply range can be extended with 18/2 wire (not available through Rollease Acmeda).
· During operation, if voltage drops to less than 10V, the motor will beep 10 times to indicate a power supply issue. · Motor will stop running when the voltage is lower than 7V and it will resume again when the voltage is greater than 7.5V.
DC Power Supply

Power Supply

Motor

MTBWAND18-25 Battery Tube for DCRF (no Battery) Motors
MTDCRF-CL-0.6-50 MTDCPS-18-25 Power Supply for 18/25-CL/Tilt DCRF (no Bttry) Motor
MT01-3001-069001
MTBPCKR-28 Rechargeable Battery Pack

Extension Cables
MTDC-CBLXT6 DC Battery Motor Cable extender 6″ / 155mm MTDC-CBLXT48 DC Battery Motor Cable extender 48″ / 1220mm MTDC-CBLXT96 DC Battery Motor Cable extender 96″ / 2440mm

Length
6 inch 48 inches 96 inches

Ensure cable is kept clear of fabric. Ensure antenna is kept straight and away from metal objects.

6 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

3 P1 BUTTON FUNCTIONS

3.1 Motor State Test

This table describes the function of a short P1 button press/release(<2 seconds) depending on current motor configuration.

P1 Press

Condition

Function Achieved

Visual Feedback

Audible Feedback

Function Described

Short Press then Release
(<2 sec)

If limit is NOT set

None

If limits are set

Operational control of motor, run to
limit. Stop if running

If motor is in “Sleep Mode” &
limits are set
(Refer to Sec.10)

Wake and control

No Action
Motor runs
Motor wakes and runs in a direction

None None None

No Action
Operational control of motor after pairing
and limit setting is completed first time
Motor is restored from Sleep mode and RF control is active

3.2 Motor Configuration Options

The P1 Button is utilized to administer motor configuration as described below and beginning in Section 4.

Activate Pairing Mode

Hold P1

P1

Approx.

Motor Response

RELEASE P1
Sleep Mode

Approx.

6 SECS

Motor Response

RELEASE P1

Reverse Direction

Approx.

0.6 Nm Motor

0.8 Nm Motor

Motor Response
RELEASE P1 Reset To Factory Settings
Approx. 14SECS

Motor Response

7 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

4 INITIAL SET-UP 4.1 Pair Motor with controller

Select channel on controller.
(Disregard if using single channel controller)

Hold P1 button on motor head

Hold STOP on controller

IMPORTANT

Motor Response

Consult user manual for your controller for information on
selecting channel.

Motor Response RELEASE P1

Motor is now in setup mode and ready for setting limits.

4.2 Check motor direction
To check travel direction of shade, press UP or DOWN on controller.

To reverse shade direction, hold both UP and DOWN until motor responds

Motor Reponse

Reversing motor direction using this method is only possible during initial set-up, prior to first time limit setting, or after a re-set of motor

8 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

4.3 Set limits
IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given.
To save upper limit, hold UP and STOP.
Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons
on controller.
To save lower limit, hold DOWN and STOP.

Quick Press = Step Long Press = Continuous Travel

Motor Response Approx. 5 SECS

Initial set-up is now complete
9 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

5 ADJUSTING LIMITS

5.1 Adjust upper limit

Hold UP and STOP on Controller until the motor responds.

Move shade to the desired upper position by pressing the UP or
DOWN button.

To save upper limit, hold UP and STOP until the motor responds.

Motor Response
SEC S
Approx.

Motor Response

5.2 Adjust lower limit

Hold DOWN and STOP on controller.

Move shade to the desired lowest position by pressing the UP or DOWN
button

To save lower limit, hold DOWN and STOP.

Motor Response

Approx.

SEC S

IMPORTANT Consult user manual for your controller or sensor.
10 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

Motor Response ROLLEASE ACMEDA

6 ADDING OR REMOVING CONTROLLERS AND CHANNELS

6.1 Using motor P1 button

Hold P1 button on motor head.

Hold STOP on controller to add or remove

Motor Response
RELEASE P1

Motor Response Approx.

6.2 Using a pre-existing controller
A= Existing controller or channel (to keep) B= Controller or channel or add or remove

Press P2 on existing controller.

Press P2 on existing controller.

Press P2 on new controller.

Motor Response

Motor Response

Motor Response

11 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

7 FAVORITE POSITIONING 7.1 Set favorite position
Move shade to the desired position by pressing the UP or DOWN button on the controller.

Press P2 on controller.

Press STOP on controller.

Press STOP on controller.

Motor Response

Motor Response

Motor Response

7.2 Send shade to favorite position
Hold STOP on controller.

Approx.

7.3 Delete favorite position
Press P2 on controller.

Press STOP on controller.

Press STOP on controller.

Motor Response

Motor Response

12 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

Motor Response ROLLEASE ACMEDA

8 ADJUSTING 0.8NM MOTOR SPEED 8.1 Increase or decrease 0.8Nm motor speed

Press P2 on controller.

Press DOWN

Press DOWN

Motor Response

Motor Response

Motor Response
IMPORTANT If motor does not react to speed adjustment, the maximum or minimum speed has already been reached.

13 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

9 TILT & ROLLER MODE 9.1 Enter tilt mode
Hold UP and DOWN on controller.

Press STOP

Motor Response Approx. 5 SECS
For slat adjustment on Venetians.
9.2 Enter roller mode (Default)
Hold UP and DOWN on controller.

Motor Response Press STOP

Motor Response

Approx.

5 SECS

Motor Response

14 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

10 SLEEP MODE 10.1 Enter sleep mode
Sleep mode is utilized to prevent a motor from moving during shipping of a fabricated shade.
Hold P1 button on motor head.

Motor Response Approx. 6 SECS Motor Response RELEASE P1
10.2 Exit sleep mode
Exit sleep mode once shade is installed. PRESS & RELEASE P1 button on motor head.

Motor Response Approx.
Motor Response MOTOR RUNS TO LIMIT
15 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

ROLLEASE ACMEDA

11 TROUBLESHOOTING

Problem
Motor is not responding
Unable to adjust or set limits. Cannot program a single Motor (multiple motors respond)

Cause A / C Adapter not plugged in. Battery in motor is depleted Power failure Transmitter battery is discharged Battery is inserted incorrectly into transmitter
Radio interference/shielding
Receiver distance is too far from transmitter Incorrect wiring
Remote is in a locked state.
Multiple motors are paired to the same channel.

Remedy
Check motor to power cable connection and AC plug.
Replace 8xAA alkaline batteries.
Check power supply to motor is connected and active
Replace battery
Check battery polarity
Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal
Move transmitter to a closer position
Check that wiring is connected correctly (refer to motor installation instructions)
Change remote status to an unlocked state
Always reserve an individual channel for programming functions
SYSTEM BEST PRACTICE – Provide an extra 15 channel remote in your multi motor projects, that provides individual control for each motor for programming purposes
Place all other motors into sleep mode (ref to P1 function overview – section 3.2 and 10.1)

info@rolleaseacmeda.com rolleaseacmeda.com
ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513

ROLLEASE ACMEDA EUROPE
Via Conca Del Naviglio 18, Milan (Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317

ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047 T +61 3 9355 0100 | F +61 3 9355 0110
Queensland Branch Unit 2/62 Borthwick Avenue, Murarrie QLD 4172

16 | AutomateTM Programming Instructions | ARCTM Cord Lift Motors

Caution: This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: –Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals