ROLLEASE ACMEDA AUTOMATE Solar Powered Wind and Light Sensor Instruction Manual
- October 30, 2023
- ROLLEASE ACMEDA
Table of Contents
SOLAR POWERED WIND & LIGHT SENSOR
AUTOMATE™ | Wind-Light sensor is a device for measuring wind speed and light
intensity.
The information is transmitted to ARC outdoor motorized shades that will move
to their top or bottom limits.
FEATURES:
- Measure wind speed with an anemometer
- Measure light intensity with a Lux meter
- LCD display
- ARC compatibility
- USB-C Charging Port
- Solar Charging Panel
- Loss of communication Safeguard Technology
SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation and
use.
Incorrect installation or use can lead to serious injury and will void
manufacturer’s liability and warranty.
It is important for the safety of persons to follow the enclosed instructions.
Save these instructions for future reference.
- Do not submerge in water or expose to extreme temperatures.
- Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product.
- Use or modification outside the scope of this instruction manual will void warranty.
- Installation and programming to be performed by a suitably qualified installer.
- Follow installation instructions.
- For use with motorized shading devices.
- Keep away from children.
- Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.
- Keep clear when in operation.
- Replace battery with correctly specified type.
Rollease Acmeda declares this equipment is in compliance with the essential requirements and other relevant provisions of R&TTE Directive 2014/53/EU
Statement Regarding FCC Compliance
This device complies with Part 15 of the FCC Rules / Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
****Do not dispose of in general waste.
Please recycle batteries and damaged electrical products appropriately.
INSTALLATION
- Find an appropriate location with direct sunlight and in a location that will see the same wind conditions the paired device will see.
- Remove the base covers
- The solar panel must be face up and in direct sunlight
- Fix the sensor to a suitable surface
- Re-attach the base covers
- Ensure the three rotating cups are in an approximately horizontal position
Transmission Distance:
35 meters indoors
200 meters open space
OVERVIEW
2.1 COMPONENTS
2.2 LCD DISPLAY
- The LCD screen lighting stays active for 30 seconds. If there is no operation, the sensor automatically switches its screen off for energy saving, but the program will keep running for normal detection and command transmissions. When the screen is off, pressing any (non-reset) button triggers the screen to be on again for another minute.
- Sun icon: indicates the light intensity detection mode.
- Flag icon: indicates the wind speed detection mode.
- Battery icon: The voltage of the internal battery is checked by its inner program once every day. The appearance of this battery icon indicates that its voltage is below 2.7V. It is recommend that the sensor is placed in direct sunlight or plug in a USB-C cable to charge the sensor for minimum of 6 hours.
- RF signal icon: displayed when transmitting a signal.
2.3 SAFEGUARD TECHNOLOGY
Once the sensor is paired to an Automate external motor, the sensor will check
in with the motor every 30mins.
If the motor does not receive the signal at the checkpoint, the motor will
close as a protective measure.
Once the Safeguard feature has been triggered, motor will only move in small
increments.
This is a sign that there is a fault in the sensor or that the internal
battery has gone flat. If this happens, you will need to place the sensor in
direct sunlight or plug in a USB-C cable to charge the sensor for minimum of 6
hours.
SETUP
3.1 PAIR THE MOTOR TO A REMOTE (IF REQUIRED)
NOTE:
- Complete setup using motor programming instructions.
- The sensor will only work if the motor is configured with the upper and bottom limits.
3.2 CHECK MOTOR DIRECTION
Confirm that motor direction is setup as below so any paired sensors will
activate correctly.
DOWN on the remote OPENS the Awning (awning moves in an outward/downward
direction).
And UP on the remote CLOSES the Awning (awning moves in an inward/upward direction).
Note: Follow motor programming instructions to reverse motor direction if
necessary.
3.3 PAIR OR UNAPIR THE SENSOR TO A MOTOR USING A PRE-PAIRED
REMOTE
NOTE:
- If the pair is successfully done, the motor can be triggered to move upward by pressing the UP button on the sensor.
- Ensure the wind and light sensor functionality on the motor is enabled prior to pairing the wind and sun sensor.
- The pair relationship is kept even if the motor power is reset or the sensor is reset to its default setting.
3.4 SETUP WIND SPEED CONTROL
NOTE: The wind speed control function can be disabled by setting its
threshold to ZERO. Other threshold values enable this function.
3.5 SETUP LIGHT CONTROL
NOTE: The light intensity function can be disabled by setting its threshold to ZERO. Other threshold values enable this function.
Condition | klux (approximate) |
---|---|
Direct Sunlight | 100 |
Daylight | 10 |
Overcast | 1 |
ADDITIONAL FUNCTIONS
4.1 DISPLAY MEASURED WIND SPEED & LIGHT INTENSITY
In the sleep mode (blank screen), pressing the Adjust button (A) can loop
through light intensity or wind speed.
When the loop icon, , is present, the system will automatically display them
in a cycle (5 seconds). The sequence is light > wind > loop (light).
4.2 DISPLAY THE PRE-SET THRESHOLD VALUE
Press the MENU button (M) repeatedly to display the pre-set threshold values
in a cycle, the corresponding icon, , flashes to indicate that the pre-setting
value is displayed. Pressing the MENU button (M) again returns to the normal
mode. The sequence is: display the light intensity threshold value > display
the wind speed threshold value > return to normal mode.
4.3 WIND SENSOR FUNCTION
Wind speed continuously exceeds the threshold value of wind speed for
longer than 3 seconds
The sensor command is executed to control the motor “UP” action
To prevent the motorized shades from frequently opening and closing under a gust, the motor does not operate for next 8 minutes
4.4 LIGHT SENSOR FUNCTION
When the environmental light intensity is higher than the threshold for 15 minutes
The sensor command is executed to control the motor “DOWN” action
After this period, the sensor temporarily disables its light detection for the next 15 minutes
When the environmental light intensity is lower than the threshold for 15 minutes
The sensor command is executed to control the motor “UP” action
After this period, the sensor temporarily disables its light detection for the next 15 minutes
NOTE : Wind sensor trigger overrides light sensor, and moves motor up to
top limit, despite motor having moved down due to strong light.
4.5 ACTIVATE/DEACTIVATE SUN & WIND SENSOR FUNCTIONALITY ON THE MOTOR
Note: Functionality activated by default.
TROUBLESHOOTING
Problem | Cause | Remedy |
---|---|---|
Motor is not responding | Sensor battery is discharged | Recharge battery with a |
USB cable
Radio interference/Shielding| Ensure transmitter is positioned away from metal
objects and that the motor aeriaVreceiver is kept straight and away from metal
Receiver distance is too far from transmitter| Move transmitter to a closer position
Power failure| Check the connection from power 1 supply to motor
Incorrect wiring| Check if wiring is connected correctly
Pairing error| Press UP button on sensor to verify pairing .
The motor’s function of detectin.: wind/light is off| Turn on the function
Motor extends then constantly retracts unexpectedly| Wind or light threshold
is too toy.| Increase the threshold to reduce sensitivity
Extend motorized shade is casting shadow onto sensor| Check & reposition sensor if necessary
Motor does not react to wind or light setting| Wind sensitivity is too high or
toc low| Adjust sensitivity
*Time interval of strong wind is less than 8 minutes| The wind triggering time length must be over 8 minutes
Time interval of light is less than 15 minutes| The light triggering time
length must be over 15 minutes
Screen not turning on| Internal Battery Flat| Place sensor in direct sunlight
or plug in the USB-C connection to charge sensor for minimum of 6 hours.
Motor is only moving in small increments (after motor setup has been
completed)| Safeguard feature| Communication between motor and sensor has been
lost. Replace the 2 x alkaline batteries and check motion sensor is working
correctly.
Motor retracted and not operating
(not getting stepping mode function)| Wind Sensor has been triggered| Once the
Wind sensor has been triggered there is an 8min lockout as a protective
measure.
Safeguard feature is not triggering| Motor and Wind sensor checking timing|
Motor and Wind sensor need to have at least 1 check in before this feature is
enabled, this occurs every 30mins.
NOTES……………..
ROLLEASE ACMEDA | USA
Level 7 / 750 East Main Street
Stamford, CT 06902, USA
T +1 800 552 5100 | F +1 203 964 0513| ROLLEASE ACMEDA | AUSTRALIA
110 Northcorp Boulevard,
Broadmeadows VIC 3047, AUS
T +61 3 9355 0100 | F +61 3 9355 0110| ROLLEASE ACMEDA | EUROPE
Via Conca Del Naviglio 18,
Milan (Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
---|---|---
Automate™ Programming Instructions | MT02-0301-072001
ROLLEASE ACMEDA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>