ROLLEASE ACMEDA Automate Li-Ion Q10 DC ARC Tubular Motor User Manual

June 6, 2024
ROLLEASE ACMEDA

Automate Li-Ion Q10 DC ARC Tubular Motor

AUTOMATETM
DC ARCTM TUBULAR MOTOR

433 MHZ BI-DIRECTIONAL

ELECTRONIC LIMIT

SELECTABLE RPM

FAVORITE POSITION

LEVEL CONTROL

AUTOMATETM | DC ARCTM motors offer a low voltage easy to use and program solution to suit a large range of applications, torques and speeds.
Leveling Control allows for precise positioning of multiple shades ensuring perfect alignment.
Additionally, a favorite position can be pre-set and recalled at any time.

FEATURES: · Electronic Limits · 433 MHz Bi-Directional RF Communication · Leveling Control · 3 x Selectable Rpm · Favorite Position · Roller & Tilt Modes · Narrow Shade Options

INSTR. MTDCBRF_Automate_DC V1.1 MAY 2021

CONTENTS
1 ASSEMBLY 2 WIRING 2.1 Power options 3 P1 BUTTON FUNCTIONS 3.1 Motor state test 3.2 Motor configuartion options 4 INTIAL SET-UP 4.1 Pair motor with controller 4.2 Check motor direction 4.3 Set limits 5 ADJUSTING LIMITS 5.1 Adjust upper limit 5.2 Adjust lower limit 6 ADDING OR REMOVING CONTROLLERS AND CHANNELS 6.1 Using motor P1 button 6.2 Using a pre-existing controller 7 FAVORITE POSITIONING 7.1 Set a favorite position 7.2 Send shade to favorite position 7.3 Delete favorite position 8 ADJUSTING MOTOR SPEED 8.1 Increase or decrease motor speed 9 TILT & ROLLER MODE 9.1 Enter tilt mode 9.2 Enter roller mode (Default) 10 SLEEP MODE 11 TROUBLESHOOTING
2 | AutomateTM Programming Instructions | DC Tubular Motors

4 5 5 6 6 6 7 7 7 8 9 9 9 10 10 10 11 11 11 11 12 12 13 13 13 13 14
ROLLEASE ACMEDA

SAFTEY INSTRUCTIONS WARNING: Important safety instructions to be read before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.
CAUTION
· Do not expose to moisture or extreme temperatures. · Do not allow children to play with this device. · Use or modification outside the scope of this instruction manual will void warranty. · Installation and programming to be performed by a suitably qualified installer. · For use within tubular blinds. · Ensure correct crown and drive adaptors are used for the intended system. · Keep antenna straight and clear from metal objects · Do not cut the antenna. · Use only Rollease Acmeda hardware. · Before installation, remove any unnecessary cords and disable any equipment not needed for powered operation. · Ensure torque and operating time is compatible with end application. · Do not expose the motor to water or install in humid or damp environments. · Motor is to be installed in horizontal application only. · Do not drill into motor body. · The routing of cable through walls shall be protected by isolating bushes or grommets. · Ensure power cable and aerial is clear and protected from moving parts. · If cable or power connector is damaged do not use.
Important safety instructions to be read prior to operation.
· It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product.
· Keep remote controls away from children. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep motor away from acid and alkali. · Do not force the motor drive. · Keep clear when in operation.

3 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

1 ASSEMBLY
Please refer to Rollease Acmeda System Assembly Manual for full assembly instructions relevant to the hardware system being used.
Step 1. Cut roller tube to required length.
Step 2. Ensure roller tube is clean and free from burrs.

Step 3. Fit required crown, drive and bracket adapters.
Tube must be close fitting with chosen crown and drive adapters. Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive, and bracket adapter kits.
Step 4. Slide Motor into tube.
Insert by aligning keyway in crown and drive wheel to the tube.

Crown

Retaining Clip
Drive

Step 5. Mount motorized tube onto brackets.
Refer to Rollease Acmeda System Assembly Manual for recommended crown, drive, and bracket adapter kits.
4 | AutomateTM Programming Instructions | DC Tubular Motors

Motor Head

Bracket

Adapter

ROLLEASE ACMEDA

2 WIRING
2.1 Power options
AutomateTM DC motors are powered from a 12V DC power source. AA Battery wands, re-chargeable battery packs and A/C power supplies are available, with a variety of quick connect extension cords. For centralized installations, power supply range can be extended with 18/2 wire (not available through Acmeda Rollease).
· During operation, if voltage drops to less than 10V, the motor will beep 10 times to indicate a power supply issue.
· Motor will stop running when the voltage is lower than 7V and it will resume again when the voltage is greater than 7.5V.
DC Power Supply

Power Supply

Motor

MTBWAND18-25 Battery Tube for 18/25mm DCRF (no Battery) Mtrs (inc Mt clips)

MTDCRF18-0.2 – 18mm DCRF Motor, .2N/80 MTDCRF25-1.1 25mm DCRF Motor, 1.1N/40r

MTDCPS-18-25 Power Supply for 18/25-CL/Tilt DCRF (no Bttry) Mtr

MTDCRF18-0.2 – 18mm DCRF Motor, .2N/80 MTDCRF25-1.1 25mm DCRF Motor, 1.1N/40r

MTDCRFQ28-2 28mm DCRF Quiet Motor, 2N/28r

MTDCPS-28-35-45 Power Supply for 28/35/45mm DCRF (no Battery) Mtr 28mm DC ARC

MTDCRF35-3 35mm DCRF Motor, 3N/28r MTDCRFQ45-3 45mm DCRF Quiet Motor, 3N/28r

MTDCRF45-10 45mm DCRF Motor, 10N/9r

MTDCRF18-0.2

MTDCKR-28 Rechargeable Wand

MTDCRF25-1.1

MTDCRFQ28-2

Extension Cables
MTDC-CBLXT6 DC Battery Motor Cable extender 6″ / 155mm MTDC-CBLXT48 DC Battery Motor Cable extender 48″ / 1220mm MTDC-CBLXT96 DC Battery Motor Cable extender 96″ / 2440mm

Length
6 inch 48 inches 96 inches

Ensure cable is kept clear of fabric. Ensure antenna is kept straight and away from metal objects.

5 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

3 P1 BUTTON FUNCTIONS

3.1 Motor state test
This table describes the function of a short P1 button press/release (<2 seconds) depending on current motor configuration.

P1 Press

Condition

Function Achieved

Visual Feedback

Audible Function Described Feedback

Short Press

If limit is NOT set
If limits are set

None
Operational control of motor, run to limit.
Stop if running

If motor is in “Sleep Mode” &
limits are set

Wake and control

No Action
Motor runs
Motor wakes and runs in a
direction

None None None

No Action
Operational control of motor after pairing
and limit setting is completed first time
Motor is restored from Sleep Mode and RF control is active

3.2 Motor configuartion options
The P1 Button is utilized to administer motor configuration as described below and beginning in Section

Activate Pairing Mode
Approx.

Hold P1

P1

Motor Response

Sleep Mode

Approx.

Motor Response

Reverse Direction
Motor Response

Approx.

NOTE
Reverse motor direction from P1 button only when motor does not have any limits.

Reset To Factory Settings
Motor Response

Approx.

6 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

4 INTIAL SET-UP 4.1 Pair motor with controller

Select channel on controller.

Hold P1 button on motor head.

Hold STOP on controller.

IMPORTANT
Consult user manual for your controller for information on selecting channel.

Motor Response

Motor Response

Motor is now in step mode and ready for setting limits

4.2 Check motor direction
To check travel direction of shade, press UP or DOWN on controller.

To reverse shade direction, hold both UP and DOWN.
Until the motor responds.

Quick Press = Step Long Press = Continuous Travel

Motor Response

IMPORTANT Damage to shade may occur when operating motor prior to setting limits. Attention should be given.
7 | AutomateTM Programming Instructions | DC Tubular Motors

IMPORTANT Reversing motor direction using this method is only possible during initial set-up.
ROLLEASE ACMEDA

4.3 Set limits
Move shade to the desired highest or lowest position by pressing the UP or DOWN buttons
on controller.

To save upper limit, hold UP and STOP. To save lower limit, hold DOWN and STOP.

IMPORTANT Cycle shade up and down prior to setting limits to settle fabric
Initial set-up is now complete

Motor Response 5 SECS
IMPORTANT After setting limits, motor will automatically exit from initial set-up mode.

8 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

5 ADJUSTING LIMITS 5.1 Adjust upper limit

Hold UP and STOP on controller.

Move shade to the desired highest position by
pressing the UP button.

To save upper limit, hold UP and STOP.

Motor Response 5 SECS

5.2 Adjust lower limit
Hold DOWN and STOP on controller.

Move shade to the desired lowest position by pressing the DOWN
button.

Motor Response 5 SECS
To save lower limit, hold DOWN and STOP.

Motor Response 5 SECS

Motor Response 5 SECS

9 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

6 ADDING OR REMOVING CONTROLLERS AND CHANNELS

6.1 Using motor P1 button

Hold P1 button on motor head.

Hold STOP on controller to add or remove.

Motor Response

Motor Response

6.2 Using a pre-existing controller

Press P2 on existing controller.

Press P2 on existing controller.

Press P2 on new controller.

Motor Response

Motor Response

IMPORTANT Consult user manual for your controller or sensor.
10 | AutomateTM Programming Instructions | DC Tubular Motors

Motor Response ROLLEASE ACMEDA

7 FAVORITE POSITIONING 7.1 Set a favorite position
Move shade to the desired position by pressing the UP or DOWN button on the controller.

Press P2 on controller.

Press STOP on controller.

Press STOP on controller.

Motor Response

Motor Response

Motor Response

7.2 Send shade to favorite position
Hold STOP on controller.

7.3 Delete favorite position

Press P2 on controller.

Press STOP on controller.

Press STOP on controller.

Motor Response

Motor Response

11 | AutomateTM Programming Instructions | DC Tubular Motors

Motor Response ROLLEASE ACMEDA

8 ADJUSTING MOTOR SPEED 8.1 Increase or decrease motor speed
Press UP.

Press P2 on controller.

Press DOWN.

Press UP. Press DOWN.

Motor Response

Motor Response

Motor Response
IMPORTANT If motor does not react to speed adjustment, the maximum or minimum speed has already been reached.

12 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

9 TILT & ROLLER MODE
9.1 Enter tilt mode
For slat adjustment on venetians. Hold UP and DOWN on controller.

Press STOP.

Motor Response

5 SECS

9.2 Enter roller mode (Default)
Hold UP and DOWN on controller.

Motor Response Press STOP.

Motor Response

5 SECS

Motor Response

10 SLEEP MODE
Enter Sleep Mode Sleep mode is utilized to prevent a motor from moving during shipping of a fabricated shade
Hold P1 button on the motor head
Motor Response

Exit Sleep Mode Exit sleep mode once the shade is installed
Hold P1 button on the motor head
Motor Response

13 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

11 TROUBLESHOOTING

Problem

Cause

Remedy

Power supply not plugged in.

Check motor to power cable connection and power plug.

Transmitter battery is discharged Replace battery

Battery is inserted incorrectly into transmitter

Check battery polarity

Motor is not responding

Radio interference/shielding

Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal

Receiver distance is too far from Move transmitter to a closer

transmitter

position

Power failure

Check power supply to motor is connected and active

Incorrect wiring

Check that wiring is connected correctly (refer to motor installation instructions)
Replace batteries in battery wand

Motor beeps 10 times when in use Battery voltage is low.

-OR-
Recharge rechargable battery pack.

Always reserve an individual channel for programming functions

Cannot program a single Motor (multiple motors respond)

Multiple motors are paired to the same channel.

SYSTEM BEST PRACTICE – Provide an extra 15 channel controller in your multi motor projects, that provides individual control for each motor for programming purposes

Place all other motoprs into sleep mode (ref to P1 button function overview – Section 3)

14 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

FCC & ISED STATEMENT
FCC & ISED STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :

  1. L’appareil ne doit pas produire de brouillage.
  2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    · Reorient or relocate the receiving antenna.
    · Increase the separation between the equipment and receiver.
    · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    · Consult the dealer or an experienced radio/TV technician for help.

Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately.

5005833

15 | AutomateTM Programming Instructions | DC Tubular Motors

ROLLEASE ACMEDA

ROLLEASE ACMEDA AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047
T +61 3 9355 0100 | F +61 3 9355 0110
ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford, CT 06902 6320 T +1 203 964 1573 | F +1 203 964 0513

Western Australia Branch Unit 1, 41 Mulgul Road, Malaga WA 6090
T +61 8 9248 5571 | F +61 8 9248 5572

Queensland Branch Unit 2/62 Borthwick Avenue,
Murarrie QLD 4172

ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
info@rolleaseacmeda.com rolleaseacmeda.com

16 | AutomateTM Programming Instructions | DC Tubular Motors

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals