ROLLEASE ACMEDA 003B9ACA3E TDBU RF Controller User Guide
- June 5, 2024
- ROLLEASE ACMEDA
Table of Contents
- ROLLEASE ACMEDA 003B9ACA3E TDBU RF Controller
- SAFETY
- FCC & ISED STATEMENT
- INSTALLER BEST PRACTICES AND TIPS
- INSTALLER
- FACTORY RESET
- BUTTON OVERVIEW
- REPLACE BATTERY
- WALL MOUNTING
- HIDE UNUSED CHANNELS
- GROUP CONTROL
- DISABLE LIMIT SETTING
- SET A FAVORITE POSITION
- CREATE CUSTOM GROUPS
- Documents / Resources
ROLLEASE ACMEDA 003B9ACA3E TDBU RF Controller
SAFETY
WARNING:
Important safety instructions to be read before installation and use.
Incorrect installation or use can lead to serious injury and will void the manufacturer’s liability and warranty. It is important for the safety of persons to follow the enclosed instructions.
Save these instructions for future reference
- Do not expose to water, moisture, humid and damp environments, or extreme temperatures.
- Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, should not be allowed to use this product.
- Use or modification outside the scope of this instruction manual will void the warranty.
- Installation and programming are to be performed by a suitably qualified installer.
- Follow installation instructions.
- For use with motorized shading devices.
- Frequently inspect for improper operation. Do not use if repair or adjustment is necessary.
- Keep clear when in operation.
- Replace the battery with the correctly specified type.
WARNING: Do not ingest battery, Chemical Burn Hazard.
This product contains a coin/button cell battery. If the coin/button cell
battery is swallowed, it can cause severe internal burns in just 2 hours and
can lead to death.
Keep new and used batteries away from children. If the battery compartment
does not close securely, stop using the product and keep it away from
children.
If you think batteries might have been swallowed or placed inside any part of
the body, seek immediate medical attention.
Do not dispose of the general waste.
- FCC ID: 2AGGZ003B9ACA3E
- IC: 21769-003B9ACA3E
- Operation Temperature Range: -10°C to +50°C
- Ratings: 3VDC, 15mA
FCC & ISED STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequencyenergy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
BATTERY MANAGEMENT
For battery motors;
Prevent discharging the battery completely for extended periods, recharge as
soon as the battery is discharged
CHARGING NOTES
Charge your motor for 9-12 hours, depending on the motor model, as per motor
instructions.
During operation, if the battery is low, the Endcap LED indicator will flash red to prompt the user to charge the system.
INSTALLER BEST PRACTICES AND TIPS
SLEEP MODE
If pre-programmed: before shipping the motor ensure the motor is put into
sleep mode so it doesn’t activate during transit.
LOCK REMOTE
Prevent users from accidentally changing the limit; ensure the remote is
locked as your last step of programming.
ZONE/GROUPS
Ask the customer the day before to think how shades will be zoned on the
remote. This may save an extra call-out.
SETTLE FABRIC
Run the fabric up and down several times to ensure the fabric has settled to
some extent and re-adjust the limits if needed.
CHARGE 100%
For battery, motors ensure the motor is fully charged as per instructions.
INSTALLERS REMOTE
Use a spare remote to individually program each shade. Then use that remote to
group rooms as per the user’s needs. If you go back and service the
installation later then, that same remote can be used to check the individual
shades.
PRODUCT RANGE
This Quick Start Programming Guide is for the Top Down Bottom Up system
(controller and remote).
P1 LOCATIONS
LED Status:
USB Cable
USB Power Supply
INSTALLER
QUICK START PROGRAMMING
STEP 1 ON REMOTE
Press ˜˜ (lower channel) or (higher channel) buttons to select the channel that needs to be programmed
STEP 2 PAIRING REMOTE WITH MOTOR
- Press the P1 button on the motor for 2 Seconds until the motor response
- The motor will respond with Jog x1
- Within 10 seconds hold the Left STOP button on the remote until the motor Jogs x2:
STEP 3 CHECK DIRECTION
Press >< (Up) or <> (Down) to check the motor direction. If correct skip to step 5.
STEP 4 CHANGE DIRECTION
If the shade direction needs to be reversed; press and hold the >< (Up) &
The operation is only valid when there are no limits.
STEP 5 SET UPPER LIMIT
Move the middle member to the desired top limit by pressing the right >< (Up) button repeatedly.
Then press and hold right >< (Up) & right STOP buttons together for 2 seconds to save the top limit.
Repeat this process using the left >< (Up) button to set desired top limit and left >< (Up) & left STOP for 2 seconds to set the lower hembar top limit.
STEP 6 SET BOTTOM LIMIT
Move the middle hembar to the desired bottom limit by pressing the right <> (Down) button repeatedly.
Then press and hold right <> (Down) & right STOP buttons together for 2 seconds to save the bottom limit.
Repeat this process using the left <> (Down) button to set desired bottom limit and left <> (Down) & left STOP for 2 seconds to set the lower hembar top limit.
STEP 7 SAVE YOUR LIMIT
Repeat steps 1-6 for all motors. Once complete Press the lock button for 5 seconds to lock the remote, the L will briefly appear on the screen.
FACTORY RESET
MOTOR RESET PROCEDURE
To reset all settings in the motor press and hold the P1 Button for 14
seconds, you should see 4 independent jogs.
MOTOR RESPONSE
BUTTON OVERVIEW
REPLACE BATTERY
Remove Battery Isolation Tab
Remove cover
Use a tool (such as a SIM card pin, mini screwdriver, etc.) to push the
battery cover release button and simultaneously slide the battery cover down.
Install Battery
Note: Tools are not provided with the remote.
WALL MOUNTING
Use supplied fasteners and anchors to attach the base to wall.
HIDE UNUSED CHANNELS
Your multi-channel remote can be configured to have anywhere between 1 or 15 visible channels. Inactive channels will not be visible when scrolling through the Channel selection.
Hold STOP and Channel Button
Remote Response: Flashing Stops
Continue holding Channel Button and select the required channel qty by
pressing >< (UP) or <> (Down)
Press STOP to confirm
Remote Response: Flashing Stops
SELECTING A CHANNEL
STEP 1
Press left and right arrow; to scroll through channels as required.
STEP 2
READY FOR CONTROL
Now while the channel is active follow the control instructions.
If no button is pressed within 4 seconds, the channel slection will automatically be confirmed.
GROUP CONTROL
Channel “0” is pre-set to control ALL shades paired to your Muli-channel remote.
CONTROLLING A SHADE
CONTROL SHADE UP OR DOWN
Lower Hembar
Middle Hembar
While the channel is displayed press >< (Up) or <> (Down) to move shade accordingly.
STOPPING THE SHADE
Lower Hembar
Middle Hembar
Press the corresponding STOP button to stop the hembar at any point. Press and hold Left STOP for 2 seconds to send shade to favorite position (if set).
DISABLE LIMIT SETTING
This mode is intended to be used after all shade programming is completed. User Mode will prevent accidental or unintended changing of limits.
Press the lock button for 5 seconds to lock/unlock the remote
SET A FAVORITE POSITION
Repeating these steps after creating a favorite position will delete it. Move Hembar to desired position by pressing >< (Up) or <> (Down) on the remote .
Move shade to desired position by adjusting hembar positions by pressing the corresponding >< (Up) and <> (Down) buttons on the remote.
STEP 1 Press P2 on controller
STEP 2 Press Left STOP
on controller
STEP 3 Press Left STOP
on controller
CREATE CUSTOM GROUPS
It is possible to copy one channel to another channel to create custom groups
Select the channel
you want to transfer
STEP 1 Press P2 on the existing controller
STEP 2 Press P2 again on the existing controller
Step 3 to be completed within 4 seconds of Step 2
Select the channel
on the new controller
STEP 3 Press P2 on new controller
Documents / Resources
|
ROLLEASE ACMEDA 003B9ACA3E TDBU RF
Controller
[pdf] User Guide
003B9ACA3E, 2AGGZ003B9ACA3E, 003B9ACA3E TDBU RF Controller, 003B9ACA3E, TDBU
RF Controller, MT02-0101, MT02, 0101-060009
---|---
Read User Manual Online (PDF format)