AUDIBAX Thunder 450 RGBW Strobo LED Cegadora Wash User Manual

June 3, 2024
AUDIBAX

AUDIBAX Thunder 450 RGBW Strobo LED Cegadora Wash

AUDIBAX Thunder 450 RGBW Strobo LED Cegadora Wash product-
img

Safety instruction

Please read the instruction carefully which includes important information

Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.

  1. Unpack and check carefully there is no transportation damage before using the unit.
  2. Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the unit.
  3. It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  4. The unit is for indoor use only. Use only in a dry location.
  5. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
  6. Disconnect main power before replacement or servicing.
  7. Make sure there are no flammable materials close to the unit while operating as it is fire hazard.
  8. Use safety cables when fixing this unit. DO NOT handle the unit by its head only, always carry by its base.
  9. Maximum ambient temperature is Ta: 40 degrees C. DO NOT operate it where the temperature is higher than this.
  10. Unit surface temperature may reach up to 75 degrees C. DO NOT touch the housing with bare hands during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
  11. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. in the installation, usage and maintenance.
  12. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
  13. DO NOT touch any wire during operation as high voltage may cause electric shock.

Warning:

  1. To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
  2. The housing and lenses must be replaced if they are visibly damaged.

Caution:

There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.

Installation:

The fixture should be mounted via its Omega Quick Release Clamp bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating and make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight. Always use a safety cable that can hold 12 times of the weight of the fixture when installing.
The equipment must be installed by professionals. It must be installed in a place where is out of the reach of people and no one can pass by or under it.

DMX CHART

6-channel mode

Channel Value Function
1 000-255 Master Dimmer
2 000-255 Strobe with increasing speed 0-100%
3 000-255 Red 0-100%
4 000-255 Green 0-100%
5 000-255 Blue 0-100%
6 000-255 White 0-100%

16-channel mode

Channel Value Function
1 000-255 Mater dimmer
2 000-255 Yellow 0-100%
3 000-255 Red 0-100%
4 000-255 Green 0-100%
5 000-255 Blue 0-100%
6 000-255 White 0-100%
7 000-255 Strobe & effect(White)
8 000-255 Strobe & effect (RGB)
9 000-255 Strobe duration
10 000-255 White color internal programs
11 000-255 Increasing speed(0-100%) of white running
12 000-255 RGB internal programs
13 000-255 Increasing speed(0-100%) of RGB running
14 000-255 Auto run color change
15 000-255 Color presets(RGB mixing)
16 000-255 Auto Run direction(L-R/R-L)

42-channel mode

Channel Value Function
1 000-255 Red 0-100%

LED Group 1

2| 000-255| Green 0-100%
3| 000-255| Blue 0-100%
4| 000-255| Red 0-100%| ****

LED Group 2

5| 000-255| Green 0-100%
6| 000-255| Blue 0-100%
7| 000-255| Red 0-100%| ****

LED Group 3

8| 000-255| Green 0-100%
9| 000-255| Blue 0-100%
10| 000-255| Red 0-100%| ****

LED Group 4

11| 000-255| Green 0-100%
12| 000-255| Blue 0-100%
13| 000-255| Red 0-100%| ****

LED Group 5

14| 000-255| Green 0-100%
15| 000-255| Blue 0-100%
16| 000-255| Red 0-100%| ****

LED Group 6

17| 000-255| Green 0-100%
18| 000-255| Blue 0-100%
19| 000-255| Red 0-100%| ****

LED Group 7

20| 000-255| Green 0-100%
21| 000-255| Blue 0-100%
22| 000-255| Red 0-100%| ****

LED Group 8

23| 000-255| Green 0-100%
24| 000-255| Blue 0-100%
25| 000-255| Red 0-100%| ****

LED Group 9

26| 000-255| Green 0-100%
27| 000-255| Blue 0-100%
28| 000-255| Red 0-100%|

LED Group 10

---|---|---|---
29| 000-255| Green 0-100%
30| 000-255| Blue 0-100%
31| 000-255| Red 0-100%|

LED Group 11

32| 000-255| Green 0-100%
33| 000-255| Blue 0-100%
34| 000-255| Red 0-100%|

LED Group 12

35| 000-255| Green 0-100%
36| 000-255| Blue 0-100%
37| 000-255| White group 1 dimming from 0-100%
38| 000-255| White group 2 dimming from 0-100%
39| 000-255| White group 3 dimming from 0-100%
40| 000-255| White group 4 dimming from 0-100%
41| 000-255| White group 5 dimming from 0-100%
42| 000-255| White group 6 dimming from 0-100%

Introduction

Thank you for selecting the Thunder 450 RGBW product. This versatile product can be used for a wide variety of effects:

  • Compact strobe fixture
  • Compact blinder fixture
  • Compact video pixel with 18 sections of individual control

As the fixture is IP20-rated, it is suitable for indoor applications,such as nightclubs, churches, and concerts…

Before using the product for the first time

  1. Read ‘Safety information’ before installing, operating or servicing the fixture.
  2. Unpack and ensure that there is no transportation damage before using the fixture. Do not attempt to operate a damaged fixture.
  3. Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the fixture.
  4. Obtain a power cable fitted with IP20 power connector.
  5. Obtain a DMX cable fitted with an IP20 connector

Fixture Overview

AUDIBAX Thunder 450 RGBW Strobo LED Cegadora Wash fig
\(1\)

MENU

1| Programming| Menu item| Description
2| DmxAdderss| A001-A512|

3

|

Run Mode

| D512| DMX

Auto

| Auto| 0-30
Speed 01 – 99

4

|

Channel

| 6ch|
16ch|
42ch|

5

|

Display

|

Light off

| light
1Min
2Min
3Min
Menu Back| light
 | 1Min
 | 2Min
 | 3Min
Light Flash| Off
 | On

6

|

Tool Balance

|

All Sw

|

Off/on







6

| ****



Balance

| Red(50-255)
---|---|---
Green(50-255)
Blue(50-255)
white(50-255)


Default

| Off
On


DMX Clea

| Off
On





7

| ****




Manual

| Dimmer| 0-255
Strobe| 0-255
Red| 0-255
Green| 0-255
Blue| 0-255
white| 0-255




8

| ****



Info

| Run Time| 0000-9999
Temperature| XXX


Disvers

| ****

Vx.xx

How to set unit

Function display: Shows the various menus and the selected functions

Button:

MODE To select the programming functions
ENTER To go forward to the selected functions
UP To the previous functions
DOWN To the next functions

MAINS IN:
Powercon connection from main power supply
DMX IN:
DMX512 link,use 3pin/5pin XLR cable to link the unit and DMX controller
DMX OUT:
DMX512 link,use 3pin/5pin XLR cable to link the next unit and output DMX signal.

MAIN FUNCTION

To select any of the given functions, press the MUSE button until the required function is showing on the display. Select the function by pressing the ENTER button again and the display will blink. Use the DOWN/UP buttons to change the mode. Once the required mode has been selected, press the ENTER button to setup, to go back to the functions without any change press the MUSE button.
The main functions are shown overleaf:

DMX Functions

Enter MUSE mode, select DMX Functions, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, DMX Channel Mode or View DMX Value.

DMX Address

To select DMX Address, press the MUSE button to show the DMX ADDRESS on the display. Use the UP/DOWN button to adjust the address from 001 to 512, press the button to setup. Press the MUSE button back to the last menu or let the unit idle one minute to exit menu mode.

DMX Channel Mode

To select DMX Channel Mode, press the ENTER button to show the DMX CHANNEL MODE on the display. Use the UP/DOWN button to select different channels, and press the ENTER button to setup. Press the MUSE button back to the last menu or let the unit idle one minute to exit menu mode.

CONTROL BY DMX

  1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter cable.
  2. The last units DMX cable has to be terminated with a 120 ohm 1/4W resistor between pin 2(DMX) and pin 3(DMX+) of a 3 pin XLR plug and plug it in the DMX output of the last unit.
  3. Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a Y cable. DMX 512 is a very high speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.
  4. The DMX output and input connectors are pass through to maintain the DMX circuit, when one of the units’ power is disconnected.
  5. Each fixture unit needs to have an address set to receive the data sent by the controller. The address number is between 1 512.
  6. The end of the DMX 512 system should be terminated to reduce signal errors.
  7. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal ( ), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal ( ), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used.

MAINTENANCE

Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:

  • A. The unit does not work, no light and the fan does not work
    • Check the connection of power and main fuse.
    • Measure the mains voltage on the main connector.
    • Check the power on LED.
  • B. Not responding to DMX controller
    • DMX LED should be on. If not, check DMX connectors and cables to see if link properly.
    • If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
    • 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one.
    • 4. Try to use another DMX controller.
    • 5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit.
  • C. One of the channels is not working well
    • The stepper motor might be damaged or the cable connected to the PCB is broken.

TECHNICAL SPECIFICATION

  • Voltage:AC100-240V/300W,50/60Hz
  • Light source: Mainly output is 216pcs of 1W white SMD LED, and aura light is used 768pcs RGB 3in1 SMD LED
  • Power consumption(Flashing mode):500W
  • Continuous lighting mode:300W
  • Lifespan:50,000 hours
  • Beam angle:80 degree for white color with optical reflecting patter,
  • 120 degree for aura
  • Dimming:0-100% linear electronic dimming
  • Strobe:0-30 times/sec
  • Control mode:DMX512,Master/slave,Auto run,manual
  • Channel:6/16/42CH
  • Cooling:silent fans keep fixtures cooling
  • 18 blocks individual controlled,can make hundreds of special effects
  • Color temperature:5000-6500K
  • Housing:Fire and explosion-proof Plastic
  • Size:460220125mm(fixture)
  • Weight:4.3kg

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AUDIBAX User Manuals

Related Manuals