Instructions

FITTING/LUMINAIRE/LEUCHTE

THIS FITTING MUST BE EARTHED AND INSTALLED BY A QUALIFIED ELECTRICIAN OR A SUITABLY COMPETENT PERSON. MAXIMUM AMBIENT TEMPERATURE 35° C

  1. Fix the wall plate to the wall. Screws and wall plugs are supplied.
  2. Remove the connector from the spring clip.
  3. Fit the FL200 bracket to the wall plate.

WIRING/CÂBLAGE/VERKABELUNG

  1. Provide a mains supply via a suitable switch or dimmer.
  2. Loosen nut A.
  3. Remove nut B and cable gland C from the connector body.
  4. Push the cable through nut A to slide out connector d from the connector body.
  5. Feed nut B and gland C over the mains input cable.
  6. Connect mains input live, neutral and earth to the matching terminals of connector d.
  7. Pull the cable back through nut A to draw the connector back into the connector body.
  8. Firmly tighten nut A.
  9. Refit gland C to the connector body and firmly tighten.
  10.  Refit nut B to gland C and firmly tighten.
  11. Refit the connector into the spring clip.

DIMMING

  • A dimmer or dimming system suitable for electronic LEd drivers must  be used.

  • Collingwood Lighting advises the following maximum loads to assist functionality of the dimming driver when used with standard mains wall dimmers.
    – 1 x units on a 250W dimmer
    – 3 x units on a 500W dimmer
    – 5 x units on a 1000W dimmer

  • For the purpose of determining circuit breakers, 1 x FL200 unit is approx equivalent to 3 x 50W halogen lamps.

  • Information given is for guidance only. All installations must comply with appropriate standards.