COLLINGWOOD LIGHTING FL01 PIR Sensor Instruction Manual

June 3, 2024
COLLINGWOOD LIGHTING

COLLINGWOOD LIGHTING FL01 PIR Sensor

Installation instructions

COLLINGWOOD-LIGHTING-FL01-PIR-Sensor-01

Installation
  1. Set A – motion sensitivity, B – Lux level sensitivity, C -Time to required levels

  2. Set required colour temperature for all units. Switch is located at the back of the floodlight under rubber cover. Use small screwdriver to lever the cover to access the switch.
    Note: Ensure the rubber cover is fitted correctly after selecting the colour temperature.

  3. Fix the circular wall bracket to the wall. Screws and wall plugs are supplied.

  4. Locate the floodlight over the circular wall bracket and tighten the screw to secure it in the required position. The aim of the floodlight can be adjusted by turning/tilting the unit.

  5. Connect the flying lead to the mains supply. A suitable waterproof junction box or enclosure must be used to maintain the IP65 rating of the product.

  6. Tighten the two side screws to clamp the floodlight in the required position.

Note: When the floodlight is switched on for the first time, you may notice a slight presence of condensation behind the glass.
The product is fitted with a breathable gland and any condensation will disappear after several hours of use.

Manual override the PIR sensor
To disable the PIR sensor, switch the floodlight on and off twice within 2 seconds. In this mode, the floodlight will remain illuminated until the PIR is activated again.
To reactivate the PIR sensor, switch the floodlight off for 10 seconds. When turned back on, the floodlight will be controlled by the

PIR sensor.
Note: Each time the floodlight is switched on single flicker is visible.

3 year warranty

t +44 (0) 1604 495 151 f +44 (0) 1604 495 095 e [email protected] w collingwoodlighting.com Collingwood Lighting, Brooklands House, Sywell Aerodrome, Sywell, Northampton NN6 0BT, United Kingdom

Installation data
  • Isolate the mains supply, prior to wiring.
  • This unit must be wired by a qualified electrician or suitable competent person.
  • The light source of this luminaire is not replaceable. When the light source reaches it’s end of life the whole luminaire shall be replaced.
Product / Produit / Produkt FL01 FL02 FL03
Input voltage / Tension / Nennspannung 220-240V AC 50/60Hz 220-240V AC
50/60Hz 220-240V AC 50/60Hz
Input current / Courant d’entrée / Eingangsstrom
0.088A 0.165A 0.145A
Input power / Puissance / Eingangsleistung 10W 20W 30W

Power factor / Facteur de puissance / Leistungsfaktor| >0.5| >0.5| >0.9
Inrush current / Courant d’appel / Einschaltstrom| 10A/0.3ms| 11A/0.5ms| 30A/5μs

Disposal of this product should be separate from household waste. Please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resource. Household users should contact their local government office for details of where and how they can take these items for environmentally safe recycling.