BOYA PM500 USB Table Microphone Instruction Manual
- June 5, 2024
- Boya
Table of Contents
BOYA PM500 USB Table Microphone
Introduction
- The BOYA Walimex pro PM500 USB desktop microphone is a professional microphone for recording broadcast quality sound. It is perfect for home studio recording, podcasting, video conferencing and for recording vocals and musical instruments. It connects to a recording device via USB.
- The microphone is easy to use and can also be operated by the speaker alone via the multifunctional rotary knob.
- The external microphone is connected to your recording device with one of the connection cables. It provides crystal clear sound of the highest quality.
- The microphone features ottom of the case that factory-mounted, removable solid table stand. There is also a 5/8 inch thread in the bottom of the case that allows the microphone to be screwed onto common microphone stands.
Warning :
- Read these instructions carefully before using your new device for the first time. They contain everything you need to know to avoid personal injury and damage to property.
- Observe all safety instructions in this user manual.
- Keep these instructions in a safe place. Pass these instructions on to the new owner if you sell or otherwise transfer the device.
How to understand the instruction manual
Markings on the device
This marking means that your device should only be disposed of in local disposal points.
Markings in the manual
Intended use
The BOYA Walimex pro PM500 USB table microphone is a versatile microphone with table stand for sound recordings in particularly high quality. It can be set up quickly and without tools, is sturdy and can be adjusted individually. It is connected to a recording device via USB.
Your microphone features the following main characteristics:
- Switchable polar pattern between cardioid and omnidirectional
- Easy operation by the speaker thanks to the multifunctional knob
- Can be used either with a table stand or via a 5/8 inch thread on a microphone stand (not included)
- .High-quality workmanship, metal housing and table stand
Important satety notes
CAUTION
Danger due to humidity
- Do not use the microphone in rain or snowfall.
- Moisture ingress can impair the functionality of the microphone.
Unpacking and checking the device
- Carefully unpack the scope of delivery.
- Check that all the items are included in the delivery:
- 1x Boya Walimex pro PM500 table microphone with USB-C port
- 1x Variable table stand
- 1x Connection cable USB-C to USB-A, 3 metres
- 1x Connection cable USB-C to USB-C, 2 metres
- 1x Satety instruction sheet
- Check whether all parts of the unit are undamaged.
NOTE : If the scope of delivery is incomplete or damaged, please contact info@foto-walser.de.
Overview of the components
- Table microphone
- Ports
- Multifunctional knob
- Polar pattern switch
- LED for cardioid pattern
- LED for omnidirectional pattern
- Mesh grille
- Table stand
- Fastening screw
- Headphone port (3,5 mm jack)
- USB-C-port
- 5/8 inch threaded bore
- USB-C to USB-C cable
- USB-C to USB-A cable
Operation
WARNING: Observe the safety instructions in the respective sections for all activities.
Using the multifunctional knob
You operate the microphone mainly with the multifunctional knob (3). This is a rotary control that can be pressed. The functions in detail:
Action | Light color | Function |
---|---|---|
Short press | Red | Mute |
Long press | Violet | Gain control |
Long press | Blue | Headphone volume |
You can then change the level as well as the headphone volume with the rotary control.
Using the polar pattern switch
By simply pressing the polar pattern switch (4), you can switch the microphone characteristic between cardioid and omnidirectional. The omnidirectional characteristic allows you to record sound from all directions. Use this function, for example, when interviewing one or more people or when recording several musical instruments at the same time. The cardioid pattern focuses the recording on sound coming from in front of the microphone. Sound from the side or rear is not picked up, or only to a limited extent. Use the cardioid pattern for specific recordings of individual sound sources such as people or musical instruments. To do this, point the microphone with the protective mesh grille (7) directly at the sound source.
Using the table stand
The table stand (8) carries the microphone ex works. Adjust the angle of the microphone by loosening the two fastening screws (9) simultaneously and tighten them again after adjustment. Always use both screws at the same time.
Mounting the microphone on a microphone stand
Remove the microphone from the table stand by loosening the two fastening screws (9) and unscrewing them completely. Gently spread the arms of the table stand and remove the microphone. Be careful not to drop it.Place the microphone on the 5/8 inch thread of your microphone stand and screw it tight. Use it as described in this manual.
Connecting to a computer
When connecting the microphone to a computer, be sure to select it as both a sound input device and a sound output device, otherwise the headphones will not work.
Tips for use
Perform a microphone test before you plan to record. Have the sound played or generated at minimum and maximum expected volume. Select a suitable level and microphone location.
Transporting and storing the unit
Transport and store the components of the set in a dry and dust-free place.
Cleaning
NOTE: Only use the cleaning agents specified in the table below.
Table Microphone | Cleaning |
---|---|
Table stand | Remove light and stubborn dirt with a |
dry or, if necessary, moistened
microfibre cloth.
Microphone
| Dab with a dusting brush or dry, soft cloth. For heavy stains, use a
slightly damp cloth, then allow to dry
completely.
NOTE : Do not use any cleaning agents or solvents! Make sure that no
moisture penetrates the housing!
Technical Specifications
Microphone|
---|---
Frequency| 20 Hz -20 kHz (+/-3dB)
Sensitivity| -36 dB +/-3 dB , OdB-1V/Pa, 1kHz
Resolution| 48 kHz/ 24 bit
Signalto-noise ratio (SNR)| 80 dB
Polar pattern| omnidirectional and cardioid
Power Supply| via connected device
Connections| USB-C, 3,5 mm headphone jack
Total weight with stand| 703 g
Disposal and environmental protection
Please dispose of the appliance at one of the local disposal points. This
service is free of charge for you.