Read all instructions BEFORE assembly and USE of product.
KEEP INSTRUCTIONS FOR FUTURE USE.
Steam Sterilizer
Owner’s Manual
3-in-1 Steam Sterilizer
WARNING
WHEN USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS
BE FOLLOWED INCLUDING THE FOLLOWING:
BURN HAZARD
To avoid risk of burns:
- Sterilizer components and water temperature can be very hot. Avoid direct contact with water and steam. Handle with care.
- Do NOT touch surfaces that may be hot. Wait until all parts of the unit have cooled before touching them.
- During use, steam is released from the vent on top of the lid – Keep hands and face away from the vent.
- Do NOT cover the vent.
- Do NOT place Sterilizer under any object that could be damaged by steam.
- NEVER remove the lid when in use.
- It is recommended to wait before removing the lid. Make sure to open the lid away from you and slowly let out any residual steam.
- Do NOT move Sterilizer when in use or when contents are still hot.
- Use oven gloves to remove from the microwave and to remove the lid when using in microwave mode.
CAUTION
- NEVER use without water.
- Always measure water amount in a separate container, and pour directly into Sterilizer.
- This is NOT a toy. Keep out of reach of children.
- Adult supervision required.
- Close supervision is necessary when any appliance is used by or near children.
- For household use ONLY-Do NOT use outdoors.
- Do NOT use appliance for other than intended use.
- The use of accessory attachments is not recommended by Chicco and could cause injuries or damage.
- Do NOT use with any bottle or item that is not intended to be heated.
- Do not place on or near a hot gas or electric burner, or in a heated oven.
- NEVER use the Sterilizer without the Lower Rack – Objects placed directly on the heating plate will cause damage to the object and the plate.
- NEVER place items on top of the Sterilizer.
- Do NOT use chemical sterilizing solutions/tablets or bleach in the Sterilizer.
- Always clean and rinse the objects before placing them in the Sterilizer.
- Not for space heating purposes.
- Do NOT place metal objects into the Sterilizer when using in microwave mode.
CAUTION
-
For glass feeding bottles – make sure glass bottles are clearly marked as microwave safe before using in microwave mode.
-
If microwave is equipped with a grill function, make sure the grill function is turned off and has cooled down before using the Sterilizer.
-
For use with 600-1200W power microwaves.
-
Do NOT microwave longer than the recommended sanitizing time shown in the chart. This may cause damage to the Sterilizer.
-
Do NOT let cord hang over edge of table or counter or touch hot surfaces.
-
A short power cord has been provided to reduce the risk of it becoming entangled or being tripped over.
-
Extension cords may be used if care is exercised in their use.
-
If an extension cord is used, its electrical rating must be as great as the rating of the appliance and not draped over the edge of the countertop or tabletop where it could
be pulled by children or tripped over. The extension cord should be a grounded type 3 wire cord. -
ALWAYS attach plug to appliance first before plugging the cord into the wall outlet.
-
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, a polarized electrical outlet will only allow the plug to be inserted
one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to modify the plug in any way. -
Remove plug from outlet when the appliance is not in use, before putting on or taking off parts, and before cleaning. Allow to cool before handling.
-
Inspect carefully before each use. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or is dropped or damaged in any manner. If Sterilizer is faulty and/or not working correctly, switch it off immediately and unplug it from the wall outlet.
-
To protect against electrical shock do not immerse cord, plugs, or Sterilizer in water or other liquid.
-
Do NOT use if the Sterilizer, plug, or cord accidentally falls into water or becomes submerged.
Parts List
Configurations
FULL SIZE: Can be used to sterilize up to (6) Bottles and Nipples.
COMPACT SIZE: Can be used to sterilize up to (2) 11 oz (330 ml) feeding
bottles OR accessories and other small items like pacifiers.
MICROWAVE SIZE: Can be used to sterilize up to (2) 11 oz (330 ml) feeding
bottles OR accessories and other small items like pacifiers.
Before First Use
Remove Microwave Base (F) from Sterilizer Tank (D) before first use.
Before using this product, the sterilization cycle should be performed (Steps
1-4) in the FULL SIZE configuration without any bottles in the Sterilizer.
Step 1
Make sure Sterilizer is unplugged and placed on a flat, stable, heat resistant surface. Remove the Sterilizer Lid (A), Upper Rack (B) and Lower Rack (C).
Step 2
WATER FOR FULL SIZE: Measure out 4.5 oz (130 ml) of water into a separate
container. Pour directly into the Sterilizer Tank (D). Continue on to page 11.
WATER FOR COMPACT SIZE: Measure out 3 oz (90 ml) of water into a separate
container. Pour directly into the Sterilizer Tank (D). Continue on to page 12.
FOR MICROWAVE SIZE: Go to page 15.
(Note: Using distilled water considerably reduces the formation of
limescale on the heating plate.)
Step 3A
FOR FULL SIZE:
Always clean and rinse bottles and accessories before placing them in the
Sterilizer.
Place the Lower Rack (C) on the Sterilizer Tank (D) and arrange feeding
bottles neck down.
Replace the Upper Rack (B) and arrange bottle accessories.
Place the Sterilizer Lid (A) back onto the Sterilizer making sure that bottles
and accessories do not prevent the lid from fitting correctly.
(Note: The parts fit together in one direction. The broad flat sides must
line up.)
Step 3B
FOR COMPACT SIZE:
Always clean and rinse bottles and accessories before placing them in the
Sterilizer.
Place the Upper Rack (B) on the Sterilizer Tank (D) and arrange objects.
Up to two 11 oz (330 ml) feeding bottles can be placed horizontally.
Place the Sterilizer Lid (A) back onto the Sterilizer making sure that objects
do not prevent the lid from fitting correctly.
(Note: The parts fit together in one direction. The broad flat sides must
line up.)
Step 4
Attach the Power Cord (E) into the back of the Sterilizer Tank (D). Always
attach plug to appliance first, then plug cord into the wall outlet.
Plug the Sterilizer into an electrical outlet. Power on the appliance by
pressing the “ON/OFF” button on the back of the Sterilizer Tank.
Press the “CYCLE” button. A light will turn on indicating the cycle has
started.
Step 5
Sterilization times may vary. When the cycle is complete, the “CYCLE” button
light will turn off.
If there is a power outage during use of the Sterilizer the cycle must be
restarted. Allow the Sterilizer to cool completely before starting a new cycle
or if complete, pour out water and dry thoroughly before storing in a cool,
dry place.
Microwave
Step 1
Remove Lower Rack (C) and the Sterilizer Tank (D) from the assembly. For microwave mode you will need the Microwave Base (F), Upper Rack (B) and Sterilizer Lid (A).
Step 2
Measure out 2.75 oz (80 ml) of water into a separate container. Pour directly
into the Microwave Base (F).
Place the Upper Rack (B) and arrange accessories or pacifiers. Up to two 11 oz
(330 ml) feeding bottles can be placed horizontally.
Place the Sterilizer Lid (A) back onto the Upper Rack (B) making sure that
accessories do not prevent the lid from fitting correctly.
(Note: The parts fit together in one direction. The broad flat sides must
line up.)
Step 3
CAUTION: To prevent damage to bottles or other items, only use on a
microwave turntable set to rotate. Reference bottle manual for any additional
requirements.
Place the Sterilizer into the microwave and select the correct time for the
Microwave Watts.
MICROWAVE WATTS | TIME |
---|---|
1200W+ | 2 minutes |
1000W – 1150W | 3 minutes |
600W – 950W | 4 minutes |
440W – 550W | 5 minutes |
Microwave Step 4
When sterilization is complete, remove from the microwave. The components are
very hot. Handle with extreme care.
Allow Sterilizer to cool completely and dry thoroughly before storing in a
cool, dry place.
Always clean your hands thoroughly before touching the sanitized objects.
Sterilized items will remain sterile inside the Sterilizer with the lid on for
about 24 hours.
Care and Maintenance
CLEANING: Make sure the Sterilizer is unplugged and the power cord is
disconnected before cleaning. Clean Sterilizer regularly. After each use allow
to cool down completely, pour out leftover water and dry the inside
thoroughly. Use a soft damp cloth to clean the Sterilizer. Do NOT use bleach
or any other harsh chemicals. Sterilizer is NOT dishwasher safe. Dry
thoroughly before storing. Store in a cool, dry place. When cleaning the
Sterilizer Tank, never immerse it in water or any other liquid.
DESCALING: It is normal for deposits of limescale to form on the heating
plate/tank or in the microwave base. These can vary in size and intensity
according to the hardness of the water used in the appliance. Over time, an
excessive amount of limescale could reduce the performance or damage the
appliance if the deposits are not regularly descaled. It is recommended that
the appliance be descaled at least once a week, or each time deposits of
limescale are found on the heating plate/tank or on the microwave base.
Use a household descaling solution for the following steps.
- Unplug the unit and make sure it has cooled down completely.
- Pour 4.5 oz (130 ml) of descaling solution into the hotplate/tank or into the microwave base, following the instructions provided for the descaling solution.
- Based on the quantity of limescale to be removed, allow the solution to act for a maximum of 2 hours. Never switch the Sterilizer on when the container is being soaked in the descaling solution.
- Empty out the heating plate/tank or microwave base.
- Remove any residue with a soft cloth and rinse several times, pouring 7 oz (200 ml) of drinkable tap water into the heating plate/tank or microwave base and empty out. Finally, dry the appliance carefully with a soft dry cloth before using it again.
Trouble Shooting and Repair
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
The Sterilizer does not turn ON. | There is no power. |
The ON/OFF switch (located on the back of the appliance) is in the “OFF”
position.| Check that there is power in the electrical outlet.
Mow the switch to ON position.
The cord plug or the cord connector has not been plugged in correctly, or they
are damaged.| Check that the plug and connector have been plugged in
correctly, and that they are in good condition. Should the product still not
work, contact Customer Service.
Appliance was submerged in water.| Discard unit.
The feeding bottles are stained at the end of the sanitation cycle.| There are
scale deposits in the appliance.| The Sterilizer needs to be descaled. See
“Care and Maintenance” section for more details.
High mineral content in tap water.| Use distilled water.
Noise- Incomplete cycle.| Excessive scale deposits on heating plate.| The
Sterilizer needs to be descaled. See “Care and Maintenance” section for more
details.
The indicator light does not come ON when you press the ‘CYCLE’ button.| |
Power OFF the appliance by pressing the ON/OFF switch (located on the back of
the appliance). Unplug the cord from the wall outlet and allow the Sterilizer
to cool completely. Plug the cord into the wall outlet and power ON the
appliance by pressing the ON/OFF switch. Press the “CYCLE” button (located on
the front of the appliance).
Should the product still not work, contact Customer service.
Rapid scale build-up.| Use of tap water with high mineral
content, softened or treated water.| Use distilled water.
The Sterilizer needs to be descaled. See “Care and Maintenance” section for
more details.
For More Information
Please do not return this product to the store.
If you have any questions or comments about this product, or are missing any
of the parts, contact us in one of the following ways:
(877)-424-4226
info@chiccousa.com
www.chiccousa.com
1826 William Penn Way Lancaster, PA 17601
Technical Information
Reference/ 00007391100070
Electrical Ratings/650W 120V~ 60Hz
Model/ 06951_SU
Made In China
= WARNING
= WARNING! Hot Surface.
= WARNING! Hot Steam.