AES XXS-3 PROTEAM Swimming Pool Heat Pump Installation Guide

June 5, 2024
AES

Automated Environmental System Installation & Operation Manual AES
XXS 3 PROTEAM Swimming Pool Heat PumpModel: XXS-3
XXS-4
XXS-6
ProTeam XXS Swimming Pool Heat Pump 

Please keep the installation manual in a safe place and read it carefully before using it.

  • The unit must be installed by professional technicians according to this manual.
  • If the unit is installed in an area that is prone to lightning strikes, please ensure to take appropriate lightning protection measures.
  • The manufacturer shall not be responsible for any damage caused to people, objects, or equipment due to failure to follow the instructions and comply with the procedures contained in this manual. Any use of this product for functions other than described in the manual shall be considered as dangerous.
  • Make sure the heat pump is installed in a well-ventilated place, away from anything which could cause a fire.
  • Do not weld any pipes if there is refrigerant inside the machine. If you need to fill gas into the unit, make sure it is in an open, well-ventilated area and not in a confined space.
  • Always drain all water inside the heat pump during winter or when the ambient temperature drops below 0℃: failure to do so may result in damage to the titanium heat exchanger due to freezing, and it will not be covered by warranty.
  • Always disconnect the power supply if you want to open the cabinet to look inside the heat pump as there is high voltage electricity inside.
  • Make sure the display controller is in a dry area to prevent damage caused by humidity.
  • The filling of gas must be carried out by professionals with an R32 operating license.

Specifications

1.1 Technical data pool heat pumps

Model XXS-3 XXS-4 XXS-6
Advised pool volume(m3) ≤ 20 ≤ 28 ≤ 37
Power Supply 220V∼240V/1/50Hz

Heating Capacity at Air 26°C, Water 26°C Hygro 80%
Heating Capacity (kW)| 3.05| 4.00| 5.60
Power Input (kW)| 0.56| 0.73| 1.03
COP| 5.45| 5.45| 5.43
Heating Capacity at Air 15°C, Water 26°C Hygro 70%
Heating Capacity (kW)| 2.51| 3.10| 4.95
Power Input (kW)| 0.55| 0.69| 1.09
COP| 4.53| 4.52| 4.54
Max Power Input (kW)| 0.95| 1.28| 1.55
Max Current (A)| 4.4| 5.8| 7.0
Refrigerant| R32| R32| R32
Heat Exchanger| Titanium| Titanium| Titanium
Air Flow Direction| Horizontal| Horizontal| Horizontal
Water Flow Volume (m3/h)| 1.5| 2.0| 3.0
Net Dimensions (LWH) (mm)| 380280350| 380280350| 420360436
Package Dimensions (LWH) (mm)| 440355405| 440355405| 480435495
Working temperature range (°C)| 8∼43| 8∼43| 8∼43
Noise (dB)| 28| 29| 29
Net Weight (kg)| 18| 20| 24
Gross Weight (kg)| 20| 22| 26

*Above data is subject to modification without prior notice.

Dimensions

AES XXS 3 PROTEAM Swimming Pool Heat Pump - Dimensions

Installation and connection

Attention:
Please observe the following rules when installing the heat pump:

  1. Any addition of chemicals must take place in the piping located downstream (after) from the heat pump.
  2. Always keep the heat pump in an upright position. If the unit has been held at an angle, wait at least 24 hours before starting the heat pump.

3.1 Heat pump location
The unit will work properly in any desired location as long as the following three requirements are met:

1. Fresh air – 2. Electricity – 3. Swimming pool filters

The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other objects are maintained. Please consult your installer for installation on an indoor pool.

ATTENTION: Never install the unit in a closed room with limited space (air volume) in which the air expelled from the unit will be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous supply of fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output.

3.2 Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running so that water is circulated through the heat pump. The heat pump will not start up if the water is not circulating.

3.3 Electrical connection
Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat pump.

AES XXS 3 PROTEAM Swimming Pool Heat Pump - Electrical
connectionAn RCD plug has been included with the power cable to provide electrical protection.

Attention:

Ensure the power plug is secure

If the plug is not secure, it may cause an electric shock, overheating, or fire.

|

Never pull out the power plug during operation

This may cause an electric shock or a fire due to over-heating.

|

Never use damaged electric wires or unspecified electric wires.

This may cause an electric shock or a fire.

---|---|---
| |

After all, connections have been made and checked, carry out the following procedure:

  1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
  2. Connect power to the heat pump and press the On/Off button on the control panel. The unit will start up after the time delay expires (see below).
  3. After a few minutes, check whether the air blowing out of the unit is cooler.
  4. When you turn off the filter pump, the unit should also switch off automatically.

Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take some time to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce the required length of time to heat the pool and the energy required to maintain the desired temperature.

Time delay – The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive contact wear. The unit will restart automatically after this time delay expires.

The first time the unit power is switched on or after any power interruptions, the heat pump starts 10s after pressing the ‘ON/OFF’ button.

3.4 Condensation

The air drawn into the heat pump is quickly cooled by the operation of the heat pump to heat the pool water, which may cause condensation on the fins of the evaporator. The amount of condensation may be as much as several liters per hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.

Electrical wiring

4.1 Swimming pool heat pump wiring diagram

3kW

AES XXS 3 PROTEAM Swimming Pool Heat Pump - .Electrical
wiring NOTE:

  1. The above electrical wiring diagram is only for your reference, please check the wiring diagram on the unit.
  2. The swimming pool heat pump must be properly grounded/earthed. Even though the heat exchanger is electrically isolated from the rest of the unit, grounding the unit is still required to protect against short circuits inside the unit.

Disconnect: A disconnection device (circuit breaker, fused or un-fused switch) should be located within sight of and readily accessible from the unit. This is common practice on commercial and residential heat pumps. It prevents remotely energizing unattended equipment and permits turning off the power at the unit while the unit is being serviced.

Display controller operation

5.1 LED wire controller Interface

AES XXS 3 PROTEAM Swimming Pool Heat Pump - controller
operation * When the heat pump is running or on standby, the display shows the water inlet temperature.

  • When the heat pump is powered on, the display shows ‘OFF’
  • Red LED will go on when you turn on the machine.

5.2 Turn on/off the heat pump

Press to turn on the heat pump, and the LED display shows the water setting the temperature for 5s, and then shows the water inlet temperature.

Press  again to turn off the heat pump.

NOTE: There is a 3 min time delay at start-up to protect the compressor.

5.3 Set the desired water temperature

Press or directly to adjust the desired water temperature (parameter d, range:.15—40 ℃), the setting will be saved after 3 seconds.
You can also adjust Parameter d to set the desired water temperature.

NOTE: the heat pump can run only if the water circulation/filtration system is running.

5.4 Parameter checking & adjustment 

Hold button for 5 seconds to enter parameter checking mode, Press or  to check the Parameters shown below.

NOTE: The other parameters which are not shown below are reserved for other functions and are not applicable to this unit.

Press  again to enter the current parameter adjustment screen, press or to make the adjustment, then press  to save the setting.

Parameter Description Range Default Remark
A Inlet water temp. -19~99℃ Real data
C Ambient temp. -19~99℃ Real data
d Desired water temp. 15℃~40℃ 27℃ Adjustable
H Return ambient temp. difference 1℃~10℃ 2℃ Adjustable
J Power-failure protection 0~1 1 (Yes) Adjustable
O Lowest ambient temp. for operation 0℃~15℃ 10℃ Adjustable

5.5 Restore factory settings

Hold and for 10 seconds to restore the factory settings.

Troubleshooting

6.1 Error code on the LED controller

Malfunction Code Reason Solution
Water temperature sensor failure P1 Water temperature sensor open circuit or
short circuit. 1. Check the sensor wiring.

2. Replace the water temperature sensor.
Ambient temperature sensor failure| P5| Ambient temperature sensor open circuit or short circuit.| 1. Check the sensor wiring.
2. Replace the ambient temperature sensor.
Too low or too high ambient temperature protection| P7| 1. Ambient temperature is out of operating range:10°C- 42 C.
2. Controller failure.| 1. Wait until the ambient temperature rises to 12°C or cools down to 40°C to restart.
2. Replace the controller.
Water flow failure| E3| 1. Insufficient or no water flow.
2. The wiring of the water flow switch is loose.| 1. Check the water pump or water piping system.
2. Check the wiring or replace the water flow switch.

6.2 Other Malfunctions and Solutions (not displayed on LED wire controller)

Malfunctions Observing Reason Solution
LED wire controller no display. No power supply. Check that the power

cable and circuit breaker are connected properly.
A heat pump is not running| LED wire controller displays the actual water temperature.| 1. Water temperature is reaching the set value, and the unit is under constant temperature status.
2. Heat pump has just started running.| 1. Check the water temperature setting.
2. Start up the heat pump after a few minutes.
Short running| LED displays the actual water temperature, and no error code is displayed.| 1. Fan NOT running.
2. Air ventilation is not enough.
3. Refrigerant is not enough.| 1. Check the cable connections
between the motor and fan: reconnect or replace if necessary.
2. Check the location of the heat
pump and eliminate all obstacles to ensure good air ventilation.
3. Replace or repair the unit.
Water stains| Water stains on heat pump unit.| 1. Condensate water.
2. Water leakage.| 1. No action.
2. Check the titanium heat exchanger carefully for any defect.

Exploded diagram

AES XXS 3 PROTEAM Swimming Pool Heat Pump - Exploded
diagram

No. Name No. Name
1 Base tray 9 Titanium heat exchanger
2 Front panel 10 Water flow switch
3 Back support 11 Capacitor
4 Fan blade 12 Switch
5 Fan grill 13 Controller
6 M4 screw 14 Handle
7 Compressor 15 Handle
8 Evaporator 16 Top cover

Maintenance

  1. Check the water supply system regularly to make sure that no air is entering the system and to check for low water flow, as this could result in reduced performance and reliability of the unit.
  2. Clean your pool and filtration system regularly to prevent damage to the unit as a result of a dirty or clogged filter.
  3. Drain all water from the unit if it will not be used for a long time (especially during winter).
  4. Before restarting the unit, check that it is filled with water.
  5. When the unit is running, there is always some water discharge under the unit (due to condensation as described above).

Automated Environmental System
Unit 1A, Wimbledon Avenue, Brandon, Suffolk, IP27 0NZ
01842 819130 | sales@automatedenvironmentalsystems.co.uk