AES PROTEAM XS Pool Heat Pump User Manual
- June 4, 2024
- AES
Table of Contents
AES PROTEAM XS Pool Heat Pump
Foreword
Thank you for choosing our pool heat pump, which is designed for mo re silent
and energy-saving user experience. It is an ideal way for green pool heating.
We hope you’ll enjoy using our heat pumps.
Thank you!
Safety precautions
We have provided important safety messages in this manual and on your heat
pump.
Please always read and obey all safety messages.
This heat pump use eco-friendly R32 refrigerant gas
Warning
The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury or injury to a third party. These signs are rare, but are extremely important.
| a. Keep the heat pump away from fire source.
---|---
| b. It must be placed in well ventilated area, indoor or closed area is not
allowed.
| c. Repair and disposal must be carried out by trained service personnel
| d. Vacuumize completely before welding. Welding can only be carried out by
professional personnel in service center.
Attention
- Please read the following instructions before installation, use and maintenance
- Installation must be done by professional staff only in accordance with this manual
- A leakage test must be performed after installation.
- Please don’t stack substances, which will block airflow near inlet or outlet area, otherwise, the efficiency of the heater will be reduced or even stopped
- Set proper temperature in order to get comfortable water temperature to avoid overheating or overcooling
- In order to optimize the heating effect, please install heat preservation insulation on pipes between swimming pool and the heat pump, and p lea se use a recomme nded cover on the swimming pool
- Connecting pipes of the swimming pool and the heater should be ≤10m
- Except for the methods recommended by the manufacturer, do not use any methods to accelerate the defrosting process or clean the frosted parts.
- If a repair is required, please contact the nearest after-sales service center. The repair process must be strictly in accordance with manual. All repair practice by non professional is prohibited
- Don’t use or stock combustible gas or liquid such as thinners, paint and fuel to avoid fire.
- Safety
- Please keep the main power supply switch far away from the children
- When a power cut happens during operation, and later the power is restored, the heater will start up
- Please switch off the main power supply in light e ning and storm weather to prevent from machine damage caused by lightning;
- To reduce the safety risk, a safety check should be done before maintenance or repair.
- Any repairing should be conducted in an area with good ventilation. The ignition source is prohibited during the inspection
- If a leakage of refrigerant gas happens, all operations must be stopped and call for emergency service immediately.
About your heat pump
Transportation
- Always keep u pright
- Do not lift the water union (Otherwise, the titanium heat exchanger inside the heat pump may be damaged
Accessories
Operating condition and range:
The heat pump will have ideal performance in the operation range Air 1 0 43
Technical parameter
Model | XS04 | XS06 | XS08 |
---|
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)| 3.5| 5.6| 7.7
COP| 5| 5.1| 5.3
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)| 2.3| 4.0| 5.4
COP| 4.0| 4.1| 4.3
TECHNICAL SPECIFICATIONS
Advised pool volume (m 3 **) *| 0~12| 5~20| 10~35
Operating air temperature ( ℃ )| 10℃~43℃
Rated input power (kW)| 0.58| 0.98| 1.26
Rated input current (A)| 2.5| 4.2| 5.5
Sound level at 10m dB(A)| 26| 27| 28
Advised water flux (m³/h)| 1~2| 2~2.5| 2.5~3.5
Water connection (mm)**| 32/38
Remarks:
This heat pump is able to perform normal within air temp 1 0 ℃℃~~+43 ℃℃,
efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heat pump performance and parameters are different
under various conditions.
Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details please refer to nameplate.
Dimension
Size (mm) Name Model| ****
A
| ****
B
| ****
C
| ****
D
| ****
E
| ****
F
| ****
G
| ****
H
---|---|---|---|---|---|---|---|---
XS04| 184| 457| 316| 209| 523| 190| 421| 490
XS06| 184| 634| 316| 209| 703| 280| 421| 490
XS08| 184| 644| 316| 209| 713| 300| 571| 640
Above data is subject to modification without notice.
Note: The picture above is the specification diagram of the pool heater, for technician’s installation and layout reference only. The product is subject to adjustment periodically for improvement without further notice.
Installation guidance
Installation reminder
Attention:
- Any chemical products should be added in the outlet tube of heatpump, even it doesn’t entre the heatpump.
- Location and dimension
The pool heat pump should be installed in a good ventilation place, with stable power supply and filter.The distance between heat pump and other objects like wall, bush or devices should be at least 50 cm, the distance between heat pump and the pool should be atleast2 meters. For indoor pool, please consult the installation technician.
- The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong enough and antirust treated;
- Please don’t stack substances that will block airflow near inlet or outlet area, and there is no barrier within 50cm behind the main machine, or the efficiency of the heater will be reduced or even stopped;
- The machine needs an appended pump (Supplied by the user). The recommended pump specification-flux: refer to Technical Parameter, Max. lift ≥10m;
- When the machine is running, there will be condensation water discharged from the bottom, please pay attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then connect a pipe to drain the condensation water out.
To use the machine, please make sure follow the order:
- Open water pump → Open heat pump
- Close heat pump → Close water pump
Wiring
- Connect to appropriate power supply, the voltage should comply with the rated voltage of the products.
- Earth the machine well.
- Wiring must be handled by a professional technician according to the circuit diagram.
- Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
- The layout of power cable and signal cable should be orderly and not affecting each other.
Reference for protecting devices and cable specification
MODEL | XS04 | XS06 | XS08 |
---|
Breaker
| ****
Rated Current (A)
| ****
4.5
| ****
8.0
| ****
9.0
Rated Residual Action Current (mA)| 30| 30| 30
Fuse(A)| 4.5| 8.0| 9.0
Power Cord(mm2)| 3×1.5| 3×1.5| 3×1.5
Signal Cable(mm2)| 3×0.5| 3×0.5| 3×0.5
R32 Gas Weight (g)| 250| 460| 550
Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire diameter must be increased.
Attention:
Make sure the plug is not damaged If the plug is not safe, it might cause electric attack, overheat, or fire ****
| Do not pull out the plug when its functioning
It might cause electric attack, overheat, or fire
| Do not use damaged or inappropriate wire
It might cause electric attack, overheat, or fire
---|---|---
Testing
Inspect heat pump before use
- The ventilating device and outlets are operating adequately and are not obstructed.
- It’s prohibited to install refrigeration pipe or components in corrosive environment.
- Inspect the electric wiring on basis of the electric wiring diagram and earthing connection.
- Double confirm the main machine power switch should be off.
- Inspect the air inlet and outlet.
Leakage detection notice and method
- Leakage checking is prohibited in closed area.
- The ignition source is prohibited during the leakage inspection. A halide torch (or any other detector using a naked flame) shall not be used.
- Leakage detection fluids can be applied with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe.
- Vacuumize completely before welding. Welding can only be carried out by professional personnel in service center.
- Please stop using while gas leakage occur, and contact professional personnel in service center.
Trial
- The user must “Start the Pump before the Machine, and Turn off the Machine before the Pump”, or the machine will be damaged.
- Before start the heat pump, please check for any leakage of water.
- In order to protect the swimming pool heater, the machine is equipped with a time lag starting function, the fan will run 1 minute earlier than the compressor when starting the machine, and it will stop running 1 minute later than the compressor when power off the machine.
- After the swimming pool heater start up, please kindly checking for any abnormal noise from the machine.
condensate water
It might have condensate water on evaporator, especially in an humid
environment, it could have liters of water, sometimes it will be mistaken as a
leakage.
Operation Guidance
-
Key function
Symbol| Designation| Function
---|---|---
****| ON/OFF| Power On/Off
| UP/DOWN| Temperature Setting From 18~40°C -
Temperature display
Celsius degree display:
means 28℃ -
Operation instruction
-
Turn on/off
Press ****to turn on/off the machine -
Temperature Setting
When the machine is on, press to set temperature.
-
-
Defrosting
Automatic defrosting: When machine is auto defrosting, will flash, and return to previous working mode when it finishes.
( Remarks: the interval between forced defrosting should be more than 30 minutes.)
Maintenance
“CUT OFF” power supply of the heat pump before cleaning, examination and repairing
-
In winter season when you don’t swim:
- Cut off power supply to prevent any machine damage.
- Drain water clear of the machine.
- Cover the machine body when not in use.
Important:
Unscrew the water nozzle of inlet pipe to let the water flow out.
When the water in machine freezes in winter season, the titanium heat exchanger may be damaged.
-
Please clean this machine with household detergents or clean water, NEVER use gasoline, thinnersor any similar fuel.
-
Check bolts, cables and connections regularly.
-
If repair or scrap is required, please contact authorized service center nearby.
-
Do not attempt to work on the equipment by yourself. Improper operation may cause danger.
Troubleshooting for common faults
Repairing Guidance
WARNING:
- If repair or scrap is required, please contact authorized service center nearby.
- Requirements for Service Personnel
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.
- Do not attempt to work on the equipment by yourself. Improper operation may cause danger.
- Strictly comply with the manufacturer’s requirements when charging R32 gas and equipment maintenance. This chapter focuses on special maintenance requirements for swimming pool heat pump with R32 gas. Please refer to the technical service manual for detailed maintenance operation.
- Vacuumize completely before welding. Welding can only be carried out by professional personnel in service center.
Failure solution and code
Failure | Reason | Solution |
---|
Heat pump doesn’t run
| No power| Wait until the power recovers
Power switch is off| Switch on the power
Fuse burned| Check and change the fuse
The breaker is off| Check and turn on the breaker
Fan running but with insufficient heating| evaporator blocked| Remove
the obstacles
Air outlet blocked| Remove the obstacles
3 minutes start delay| Wait patiently
Display normal, but no heating| Set temp. too low| Set proper heating
temp.
3 minutes start delay| Wait patiently
If above solutions don’t work, please contact your installer with detailed
information and your model
number. Don’t try to repair it yourself.
Note: If the following conditions happen, please stop the machine immediately, and cut off the power supply immediately, then contact your dealer:
- Inaccurate switch action.
- The fuse is frequently broken or leakage circuit breaker jumped.
Error code
Error code | Description |
---|---|
PP1 | Inlet water temperature sensor malfunction |
PP2 | AIN2 connected temperature sensor malfunction |
PP3 | AIN3 connected temperature sensor malfunction |
PP4 | Gas return temp sensor malfunction |
PP5 | Environment temperature sensor malfunction |
PP7 | Over low temperature of environment |
EE1 | Overhighpressure protection |
EE2 | Over low pressure protection |
EE3 | Water flux switch malfunction |