Perenio PEMUV01 Mini Indigo Portable UV Lamp User Guide

June 5, 2024
Perenio

PEMUV01 Mini Indigo Portable UV Lamp
**User Guide

**

PEMUV01-PEMUV02 UV Mini Indigo
Portable UV Lamp

**GENERAL DRAWING

**

1 UV Tube
2 LED Indicator
3 Power Button
4 MicroUSB Port

GENERAL INFO

Article PEMUV01 (White), PEMUV02 (Black)
Specification

5VDC (Input), 3.7V max, 500mA, 50/60Hz, 2.5W (Power), UVC light, 187nm and 253.7nm (Wavelength), 2,100μw/cm2 (Intensity), up to 9m2 (Coverage area), 360° (Coverage angle), non-removable battery (Capacity: 2,000mAh, charging time: 4 hours, discharge time: 2 hours). Operating conditions: 0°C to +40°C, up to 50% RH (non-condensing). Dimensions (LxWxH): 50mm x 60mm x 182mm

Recommended  Exposure Time1| 30 minutes (for area of up to 2.5m2), 60 minutes (for area of up to 5m2), 90 minutes (for area of up to 7.5m2)
Casing2| IP20 Protection Class, bulb type T5, ABS plastic (Lamp casing), quartz glass (UV tube)
Scope of Supply| UV Mini Indigo Portable UV Lamp, USB-MicroUSB Cable (0.6 m), Quick Start Guide, Warranty Card
Warranty| 2 years (UV tube lifespan: 15,000 hours)

INSTALLATION AND CONFIGURATION3

  1. Unpack the UV Lamp and connect it to the source of power using USB-MicroUSB Cable.
    NOTE. Any suitable USB Charger (Output: 5V/0.5A) may be used to connect the device to the mains socket.

  2. Wait for the battery to be recharged (It will take no more than 4 hours, and when fully charged, the LED Indicator of the Power Button will stop flashing red).

  3. Disconnect the UV Lamp from the source of power and install it on a flat horizontal surface in the desired area to be UV-disinfected.

  4. Press the Power Button to start the UV exposure process.
    NOTE that the UV exposure will start 15 seconds after pressing the Power Button, which allows the User safely leave the room, or switch off the device during this period. The LED Indicator will be blinking blue during the 15-second delay period.

  5. The UV Lamp will be automatically switched off 30 minutes after the UV exposure process is started. Switch it on again, if required.

SAFETY OPERATION RULES

The device shall be used as described in this QSG and a complete manual only. Any other use not specified therein may cause fire and other hazards, as well as injury to persons. The most effective way to use the device is in rooms with no air circulation at an ambient temperature of +24°C to +26°C. It is forbidden to operate the device if any part of the device is damaged or cracked. The device shall not be installed outdoors, or near water including humidifiers. The device shall be kept away from direct sunlight, moisture, and vibration. It is not allowed to drop or throw the device, as well as attempt to repair it on one’s own. It is not allowed to use the device with a damaged USB MicroUSB cable, or put this cable near radiators, stoves or heaters. It is not allowed to use detergents to clean any part of the device. If the UV tube is broken, all particles shall be swept into a plastic bag, sealed, and disposed of properly, as well as the room must be well-ventilated because the device contains mercury. Do not use a vacuum cleaner to pick up the waste and glass particles. Contact your local waste collection agency for proper disposal procedures. Keep children away from the device, because it may emit a light attractive to them. Serious injury and electrocution might be possible. This device is intended to be operated by adults only.
WARNINGS AND PRECAUTIONS
UVC LIGHT IS HARMFUL TO THE EYES! DON’T LOOK AT THE UV TUBE DURING OPERATION! The Portable UV Lamp is not a medical device. People, pets, and plants must not be present in the room under UVC exposure. Read and understand all instructions and precautions in this QSG and a complete manual. Failure to follow manufacturer instructions may result in fire, electric shock, and other hazards, as well as lead to serious injury to persons. Warnings, precautions, and instructions herein cannot cover all possible hazardous situations that may occur. The user must show common sense when using the device. It is forbidden to look into operating UV tubes, because any UVC light exposure causes significant eye damage, as well as may cause skin damage. So, whenever the device is powered on, wear UV eye and skin protection. Ingestion or contact with mercury or its vapor is hazardous to health. So, if the device is broken, avoid contact with mercury. It is forbidden to touch the UV tube with wet hands. The device is not intended to be used for the removal of active mold growth. The UVC light exposure to existing mold growth can cause respiratory irritation and allergic symptoms. The UVC light exposure may also cause fabric and paint discoloration. The UVC light of the device does not provide a tanning effect, while its exposure to uncovered skin areas for more than 2-3 minutes will cause burns. Do not use an incompatible USB Charger to recharge the device.

TROUBLESHOOTING

  1. The UV Lamp does not power on Low battery level. Recharge the battery.
  2. The UV tube does not work: The UV tube is damaged, or the end of life of the UV tube occurred.

Replace the UV tube.

  1. Please ventilate the room for at least 30 minutes after each UV lamp exposure. During the UV Lamp exposure, all doors and windows in the room must be closed.
  2. This device is for indoor installation only.
  3. Manufactured by Perenio IoT spol s r.o. (Na Dlouhem 79, Ricany – Jazlovice 251 01, Czech Republic). Made in China. See operating conditions and date of manufacture on the individual packaging. All information contained herein is subject to amendments without prior notification of the User. For current information and details on the device description and specification, connection process, certificates, warranty, and quality issues, as well as the Perenio Smart/Perenio Lite app functionality, see relevant Installation and Operation Manuals available for downloading at perenio.com/documents. All trademarks and names herein are the property of their respective owners.

Doc Date: 25/5/2022
Version: 2.0.1
©Perenio IoT spo l s r.o.
All Rights Reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals