Perenio PELUV01 Ultraviolet Lamp User Guide

June 5, 2024
Perenio

Perenio PELUV01 Ultraviolet Lamp User Guide

PELUV01 UV Lamp Ultraviolet Lamp Quick Start Guide

 PACKAGE CONTENTS

ASSEMBLY INSTRUCTION

Power Link device is sold separately

GENERAL INFO

Specification| 40V to 100V (Output), 100mA to 250mA, 220VAC to 240VAC (Input), 50/60Hz, 20W  Power), electrical ballast, UVC light, 260-275nm (Wavelength), 78μw/cm2 (Intensity), up to  30m2 (Coverage area), 240° (Coverage angle). Dimensions: 610 mm x 30 mm x 50 mm (Lamp bracket), Ø26 mm x 588 mm (UV tube)
---|---
Recommended
Exposure Time1| 15 minutes (for the area of up to 10 m2), 30 minutes (for the area of up to 20 m2), 45  minutes (for the area of up to 30 m2)
Casing2| IP20 Protection Class, base type G13, bulb type T8, pig iron (Lamp bracket), quartz glass (UV tube)
Scope of Supply| PELUV01 UV Lamp (UV tube ❶ and lamp bracket ❷), power cord ❸, screws and dowels ❹, mounting brackets ❺, Quick Start Guide, Warranty Card
Warranty| 2 years (UV tube lifespan: 6,000 hours)

INSTALLATION AND CONFIGURATION3

  1. Unpack the UV Lamp and accessories and mount brackets ❺ in the desired UV Lamp installation area using screws ❹ (See Figure ❻).
  2. Fix the lamp bracket ❷ into mounting brackets (See Figure ❼).
  3. Insert the UV tube ❶ into the lamp bracket (See Figure ❽).
  4. Connect the power cord ❸ to the UV Lamp (Don’t plug it into the source of power).
  5. Select one of two options to operate the UV Lamp.

Option 1 (See ❾a). Remote operation via a Perenio® Power Link device.

a. Activate the Power Link device in the Perenio Smart or Perenio Lite mobile application as described in a corresponding user  manual (Power Link device is sold separately);
b. Power off the activated Power Link device (Don’t unplug it from the source of power);
c. Connect the UV Lamp to the Power Link device using the power cord;
d. Use functionality of the Power Link device to switch on or off the UV Lamp remotely from the mobile app (e.g. timers,  scenarios, power on/off function).
NOTE  that if used with the Power Link device, the UV Lamp may additionally be managed from Google Home, Yandex Smart ome (Alice), Amazon Alexa, or Apple Siri apps. Follow instructions specified in corresponding guides of Apple, Google, or Yandex applications or refer to the FAQ Section of perenio.com website.

Option 2 (See ❾b). Manual operation.
a. Plug the UV Lamp into the mains socket to power it on;
b. Unplug the UV Lamp from the mains socket to power it off.

ATTENTION! ALWAYS PLUG AND UNPLUG THE DEVICE WITH DRY HANDS!

SAFETY OPERATION RULES

The device shall be used as described in this QSG and a complete manual only. Any other use not specified therein may cause fire,  electric shock, and other hazards, as well as injury to persons. The most effective way to use the device is in rooms with no air circulation at an ambient temperature of +25°C. The device must be installed a minimum of 1.8 m away from plastic and rubber materials such as flexible duct, wire insulation, filters, etc., because the UVC light may damage them. Otherwise, such materials must be protected from direct UVC light using aluminum foil tape. It is forbidden to operate the device if any part of the device is damaged or cracked. The device shall not be installed rooftop or outdoors, or near water including humidifiers. The device shall be kept away from direct sunlight, moisture, and vibration. It is not allowed to use the device with a damaged power cord, or put the power cord near radiators, stoves, or heaters. It is recommended to replace the UV tube once a year notwithstanding its good condition. Prior to powering on the device, the UV tube shall be cleaned with a cotton cloth to remove dirt and fingerprints,  otherwise, it may shorten the UV tube lifespan. It is not allowed to use any detergents to clean any part of the device. If the UV tube is broken, all particles shall be swept into a plastic bag, sealed, and disposed of properly, because the device contains mercury.  Do not use a vacuum cleaner to pick up the waste and glass particles. Contact your local waste collection agency for proper disposal procedures. Keep children away from the device, because it may emit a light attractive to them. Serious injury and electrocution might be possible. This device is intended to be operated by adults only.

WARNINGS AND PRECAUTIONS

UVC LIGHT IS HARMFUL TO THE EYES! DON’T LOOK AT THE UV TUBE DURING OPERATION!
The UV Lamp is not a medical device. People, pets, and plants must not be present in the room under UVC exposure. Read and understand all instructions and precautions in this QSG and a complete manual. Failure to follow manufacturer instructions may result in fire, electric shock, and other hazards,  as well as lead to serious injury to persons. Warnings, precautions, and instructions herein cannot cover all possible hazardous situations that may occur. Users must show common sense when using the device.
It is forbidden to look into operating UV tubes, because any UVC light exposure causes significant eye damage, as well as may cause skin damage. So, whenever the device is powered on, wear UV eye and skin protection.

To prevent exposure to UV light,  disconnect the device from the source of power as soon as the disinfection process is completed. Ingestion or contact with mercury or its vapor is hazardous to health. So, if the device is broken, avoid contact with mercury. It is forbidden to touch the UV Lamp with wet hands. The device is not intended to be used for the removal of active mold growth. The  UVC light exposure to existing mold growth can cause respiratory irritation and allergic symptoms. The UVC light exposure may also cause fabric discoloration, as well as damage to plastic and rubber materials. The UVC light of the device does not provide a  tanning effect, while its exposure to uncovered skin areas for more than 2-3 minutes will cause burns.

TROUBLESHOOTING

  1. The UV Lamp does not power on: The UV tube is not in close contact with the lamp bracket. Reassemble the UV Lamp device.
  2. The UV tube does not work: The UV tube is damaged, or the end of life of the UV tube occurred. Replace the UV tube.
    1. Please ventilate the room for at least 30 minutes after each UV lamp exposure. During UV Lamp exposure, all doors and windows in this room must be closed. Exposure time should be increased, if the room temperature is below +20°C or above  40°C, or when the device is operated in a wet environment like a bathroom. A single UVC light exposure period shall not exceed  90 minutes. It is recommended to use the UV Lamp once or twice a week for about 30 minutes each time.
    2. This device is for indoor installation only. Operating conditions: 0°C to +40°C, up to 75% RH.
    3. Manufactured by Perenio IoT spol s r.o. (Na Dlouhem 79, Ricany – Jazlovice 251 01, Czech Republic). Made in China. See operating conditions and date of manufacture on the individual packaging. All information contained herein is subject to amendments without prior notification of the User. For current information and details on the device description and specification, connection process, certificates, warranty and quality issues, as well as the Perenio Smart/Perenio Lite  app functionality, see relevant Installation and Operation Manuals available for downloading at  perenio.com/documents. All trademarks and names herein are the property of their respective owners.

Doc Date: 12/11/2020 Version: 2.0.0