ORION ORCAN3 LED Flat Par Can Party Light Owner’s Manual

June 5, 2024
Orion

Owner’s Manual
SAVE THIS MANUAL FOR FUTURE REFERENCE

ORION ORCAN3 LED Flat Par Can Party Light -

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER ON THIS LIGHT. THERE ARE NO  USER-SERVICEABLE PARTS INSIDE. REFER ALL SERVICING TO QUALIFIED TECHNICIANS.
 NEVER look directly at the laser emitters serious eye injury can occur.
This symbol indicates that there is laser radiation emitted from this unit.
The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user of Othe presence of “dangerous” voltage within the product’s enclosure that may be sufficient magnitude to constitute a risk of electric shock to humans. Users should exhibit extra safety when this symbol appears in this instruction manual and follow all precautions as they are stated.

  1. Read these instructions thoroughly before using this item. Heed all warnings. Follow all instructions.

  2. Disconnect from thepower source before servicing.

  3. REPLACE FUSE WITH SAME TYPE AND RATING.

  4. This product is for indoor use only! To prevent fire or electric shock, do not expose this equipment to rain or moisture. Don’t store or operate this product near any liquids.

  5. Do not store or operate this product near any heat sourcessuchasradiators, heat registers, stoves, or other apparatus(including
    amplifiers)that produce heat.

  6. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has twobladeswithone wider than the other. A grounding plug has two blades and around a grounding prong. The wide blade or third prong is provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.

  7. Protect all wires connected to this unit from beingwalkedonorpinched, particularlyplugs and the point wheretheyexit from the unit. When removing the cord from the power outlet, remove it by holding the plug not by pullingthe cord.

  8. Unplug the unit during lightning storms or when unused for long period of time.

  9. Allow the unit to cool down after1or 2hours of continuous operation to prevent heat stress damage.

  10. Whenwiringthisunit and all other equipment used in connection to this unit make sure that all of your equipment is turned OFF.

  11. Make sure the distance between the fixture and the lighted object is not less than 0.5meters. Keep combustible and/or explosive materials away from this unit.Donot blockthe ventilation slots.

  12. Inthe event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please return the unit to the nearest authorized technical assistance center.

  13. The unit should never be connected to anykindofexternalACdimmer. Operateonlyatintendedvoltage.

  14. Make sure thepower cord is never pinched or damaged.

  15. Never disconnect thepower cord by pulling or tugging on the cord.

  16. Never carry the fixture directly from the cord. Always use the hanging/mounting bracket.

  17. Before placing, installing, rigging, or suspending any product, inspect all hardware, suspension, cabinets, transducers, brackets, and associated equipment for damage. Any missing, corroded, deformed, or non-load-rated component could significantly reduce the strength of the installation, placement or array. Anysuchcondition severely reduces the safety of the installation and should be immediatelycorrected. Useonlyhardwarewhich is rated forthe loading conditions of the installation and any possible short-term, unexpected overloading. Never exceed the rating of the hardware or equipment.

  18. ALWAYS use a safety chain or cable between the unit and overhead suspension trusstoensur esafetytopersons.

  19. Consult a licensed, Professional Engineer regarding physical equipment installation. Ensure that all local, state, and national regulations regarding the safety and operation of the equipment are understood and adhered to.

  20. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or object shavefalleninto the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

UNPACKING

Thank you for choosing our LED Flat Par Can (ORCAN3). For your own safety, please read this manual before installing the device. This manual covers the important information on installation and applications. Please install and operate the fixture with the following instructions.
This LED Flat Par Can (ORCAN3) uses 6 x 10W LEDs, the LEDs are used for their long life, low power consumption, high brightness, and excellent color.
The LED Flat Par Can (ORCAN3) can be controlled by DMX512, sound-activated, automatic, or as a Primary/Secondary device. It can be used for many different scenarios including stage lighting, theatre lighting, or anywhere that needs lighting.

ORION ORCAN3 LED Flat Par Can Party Light - UNPACKING

FEATURES & SPECIFICATIONS

Functions

  1. Primary/Secondary
  2. Sound activated
  3. Automatic
  4. DMX 512
  5. IR remote control (optional)
  6. Color mixing
  7. Color change
  8. 0~100% dimmable
  9. Strobe effect

Specifications
LED quantities: 6 pcs x 10W
Input Voltage: 100V-240V~, 50/60Hz
Power consumption: 70W
Channel: 6/10 CH
Beam Angle: 40°
Display Screen: LCD display
Color: RGBWA+UV 6 in 1
Material Science: Iron alloy

Packing & weight:
Size: 180mm x 180mm x 75mm
Net Weight: 1.2kg
Packing: 190mm x 190mm x 110mm
Gross Weight: 1.4kg

ORION ORCAN3 LED Flat Par Can Party Light -
Specifications

OPERATION INSTRUCTIONS

  1. Don’t turn on the device if it’s been through severe temperature changes, especially after transportation. Operate at a stable temperature, avoiding drastic temperature changes to help avoid damage to the LEDs (etc) due to these environmental changes.
  2. Avoid excessive shock or vibration of this device during transportation or when being moved.
  3. Do not handle the light by the head only to help stop any damage to the mechanical parts.
  4. Do not expose the device to excessive heat, moisture or environments with dust, especially during installation. Also, to avoid electric shock, do not run the power lines across the floor.
  5. Make sure the location of installation is in safe and in good condition before installing the device.
  6. Ensure the safety chain is secured properly and check whether the screws are fastened properly.
  7. Make sure the lenses are in good condition, it’s recommended to replace any lens if there is any damage or scratches.
  8. Make sure the device is operated by qualified personnel who know how to operate the device.
  9. It’s recommended to keep the original packaging.
  10. Do not try to change or modify the device without any instruction by the manufacturer, a qualified technician an authorized service agent.
  11. The warranty is void if there are any malfunctions due to not following the owner’s manual instructions or if operated if not in fully working condition (short circuit, electronic shock, lamp broke, etc.).

ORION ORCAN3 LED Flat Par Can Party Light -
INSTRUCTIONS

MENU OPERATIONS
MENU: Access the menu.
UP: Add a key or selection on the key; increase the value function, and shift on the menu.
DOWN: Reduction key or key under the selected; decrease the value function down menu.
ENTER: It is used to select and confirm/store the current selection.

MENU DISPLAY INSTRUCTIONS
A001 (A001 – A512) DMX512 address setting
CHND (6CH/8CH/10CH) DMX Channel mode
CLO1 (CLO1 -CL32) Single-color mode (32 colors). Select color with “UP”

and “DOWN”.
CC99 (CC01 CC99)| Color-changing mode. Press “ENTER” to adjust the speed.
EE99 (EE01 – EE99)| Color pulsing mode. Press “ENTER” to adjust the speed.
FF99 (FF01 – FF99)| Fade mode. Press “ENTER” to adjust the speed.
STO1 (STO1 – ST32)| Strobe with the selected color. Select color with “UP” and “DOWN”. Press “ENTER” to adjust speed.
SOU1 (SOU1/2/3/4)| Sound activated mode. Press “ENTER” to adjust the speed.
“SOUN1”: Sound-activated color changing
“SOUN2”: Sound-activated color pulsing
“SOUN3”: Sound-activated color changing with strobe effect
“SOUN4”: Sound activated color-changing + pulsing + strobe effect
Press “ENTER” to adjust the sensitivity. (se01-99)
NANU| Manual mode. R/G/B/W/A/UV (0-255)
IRCL (ON/OFF)| IR remote control ON/OFF
LED (ON/OFF)| Display ON/OFF
T000 (OFF/40-100)| Thermal setting (OFF/40-100)

DMX CHANNELS

Channel 6-Channel Mode 8-Channel Mode 10-Channel Mode
CH1 0-255 Red dimming 0-255 Master dimming 0-255 Master dimming
CH2 0-255 Green dimming 0-9 Ught off; 10-255 strobe (slow to fast)

0-255 Red dimming
CH3| 0-255 Blue dimming| 0-255 Red dimming| 0-255 Green dimming
CH4| 0-255 White dimming| 0-255 Green dimming| 0-255 Blue dimming
CHS| 0-255 Yellow dimming| 0-255 Blue dimming| 0-255 White dimming
CH6| 0-255 UV dimming| 0-255 White dimming| 0-255 Yellow dimming
CH7| | 0-255 Yellow dimming| 0-255 UV dimming
CH8| | 0-255 UV dimming| 0-9 Ught off; 10-255 strobe (slow to fast)
CH9| | | 0-9 Light off
| | 10-50 Single color mode. Adjust CH10 for color selection.
| | 51-100 Color-changing mode. Adjust CH10 for speed.
| | 101-150 Fade mode. Adjust CH10 for speed.
| | 151-200 Color pulsing mode. Adjust CH10 for speed.
| | 201-220 Sound-activated color changing
| | 221-240 Sound-activated color pulsing
| | 241-255 Sound-activated color changing with strobe effect
CH1o| | | 0 Light off; 1-255 speed setting

REMOTE CONTROL

ORION ORCAN3 LED Flat Par Can Party Light - REMOTE
CONTROL

Up and Down Buttons: Adjust the intensity
ON/OFF buttons: Light ON/OFF
R/G/B/W/A/UV: single colors
Number 1-9: 9 preset colors
Number 0: Choose 1 of 32 colors by pressing the up and down buttons on the remote
AUTO: Color-changing mode. Adjust speed by pressing the up and down buttons.
STROBE: Strobe mode with 32 available colors. Adjust speed by pressing the up and down buttons.
FADE: Fade mode. Adjust speed by pressing the up and down buttons.
SOUND: Sound activated mode. Select modes by pressing the up and down buttons.

ORION ORCAN3 LED Flat Par Can Party Light - Up and Down
Buttons

MAINTENANCE AND CLEANING

The following need to be considered during inspection:

  1. There must not be any deformations on the housing (ceiling, suspension, trussing).
  2. The electric power supply cables must not show any damage, material fatigue or sediments.

Further instructions, depending on the installation area and usage, have to be adhered to by a skilled installer and any safety concerns must be removed.
CAUTION! Disconnect from mains before starting maintenance operation.
In order to keep the device in good condition and extend the lifetime, we suggest regular cleaning.

  1. Clean the lenses each week to avoid the lights being affected due to the accumulation of dust.
  2. Clean frequently using a moist, lint-free cloth, and never use alcohol or solvents. Should you need spare parts, please order genuine parts from your local dealer.

CASCADE INSTALLATION

The ORCAN3 provides a convenient outlet that can minimize wiring and improve overall safety when used properly. Please carefully read all of the important safety tips shown below for long and safe use of your lighting equipment.

IMPORTANT

  1. Do not overload the convenience outlet. Make sure power drawn from the first outlet does not exceed the limits shown on the chassis.
  2. Always inspect the cords and plugs before use. Do not use outlets or cords that have exposed wiring, or are worn or damaged. Replace electrical cords that have worn or damaged insulation and remember to pull the plug, not the cord to extend the life of the cord itself.
  3. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The main plug of the power supply cord shall remain readily operable. Unplug this apparatus during lightning storms or when unused for long periods of time. Route cords away from traffic to avoid tripping hazards and unnecessary wear on the power cord.
  4. Never Break Off the Third Prong on a Plug. Replace broken 3-prong plugs and make sure the third prong is properly grounded.
  5. Keep line cords away from heat, water and oil. They can damage the insulation and create a shock hazard.
  6. Do not tie cords in tight knots. Knots can cause short circuits and shocks. Loop the cords or use a twist lock plug.
  7. Be aware that unusually warm or hot outlets or cords may be a sign that an unsafe wiring condition exists. Unplug any cords or extension cords from these outlets and do not use them until a qualified electrician has checked the wiring.

The AC power cords supplied purposefully have 2 blades and one grounding prong. If your outlet is not equipped to handle this type of plug, do not attempt to forcefully plug this AC power cord into the outlet, and do not alter the plug so that it can fit in the outlet. The only course of action you can take is to find another outlet that is properly equipped to handle a grounded plug or have an electrician upgrade your electrical outlet. Be sure that the plug is well connected so that it does not disconnect in the middle of usage. If at any point in time the supplied AC power cord is punctured or damaged replace it with a new power cord from a local electrician.
Always connect the fixture to a circuit with a suitable electrical ground.
To determine the power requirements for a particular fixture, see the label current rating at the ratings plate of the fixture. A fixture’s listed current rating indicates its average current draw under normal conditions.

To ensure the convenience outlet is never overloaded follow the following steps:
(a) Mark down the RATED INPUT current for all devices connected to the convenience outlet.
(b) Calculate the sum of all of these currents to get the total current drawn from the outlet.
(c) Make sure this total current is less than the MAX current rating marked below the outlet. Keep in mind the MAX current is the power available from the very first convenience outlet.

Orion Lighting – One (1) Year Manufacturer’s Defect
One Year Limited Warranty: If this product should fail within one year of the original purchase date due to a manufacturing defect, simply return the product to your Orion dealer with the original proof of purchase and it will be repaired free of charge. This warranty excludes damage considered by the vendor to be the result of improper installation, normal wear, abuse or shipping damage. See your Orion dealer for details. Warranty valid in Canada and the United States. Other territories may vary.

www.orion-fxlights.com
Distributed in the US by: Yorkville Sound
4625 Witmer Industrial Estate
Niagara Fall, New York
14305
Printed in China
Manual-Owners-ORION-ORCAN3-00-2v3
October 13, 2021

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Orion User Manuals

Related Manuals