Laserliner 080-985 Distance Master LiveCam Instructions

June 5, 2024
Laserliner

Laserliner 080-985 Distance Master LiveCam

Laserliner-080-985-Distance-Master-LiveCam-

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Function / Application

Laser distance meter with camera function
Perpendicular areas, circular areas, circular volumes, triangular areas and trapezoidal areas can be determined using this multi-functional laser rangefinder. It can also determine indirect heights and take point-to-point measurements. An HD camera also acts as a spotter during measurement. The measurement data can be transferred to mobile devices via the Bluetooth interface using the free MeasureNote app.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Clean and dry the device before use.
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Note local and national safety instructions to ensure proper use of the device.

Safety instructions Using class 2 lasers

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.

  • Local operating restrictions – for example, in hospitals, aircraft,
    petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & Co. KG hereby declares that the DistanceMaster LiveCam radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED).
    The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=AKK

DESCRIPTION

  1. Laser reception field
  2. Display
  3. Battery compartment (backside)
  4. Connection socket for USB charger
  5. Camera
  6. Laser outlet
KEYPAD:
  • a Function menu / Timer function
  • b Laser on / measure / min/max continuous measurement
  • c Subtraction function/back / View saved measured values and screenshots
  • d Camera function / Screenshot
  • e ON / OFF / back
  • f Addition function / before
  • g Settings menu
DISPLAY:
  • h Battery symbol
  • i Digital bubble level
  • j Set measuring function
  • k Measurement point (reference) front / thread / rear
  • I Intermediate values / min/max values
  • m Measurement values / Measurement results

Inserting rechargeable batteries

Open the battery compartment and insert the rechargeable batteries (3x NiMH, type AAA) as indicated by the installation symbols. Be sure to pay attention to polarity. The rechargeable batteries
can be charged in the device with the supplied USB charging cable. ****

Switch on, measure and switch off:

Settings menu:

Laserliner-080-985-Distance-Master-LiveCam-
FIG-6

  • Select setting option
  • Change value
  • Save setting (optional)
  • Exit menu / Delete the last measured value
Addition and subtraction of lengths:

Laserliner-080-985-Distance-
Master-LiveCam-FIG-8

Further lengths are added by pressing the DIST button.

min/max continuous measurement:Laserliner-080-985-Distance-Master-
LiveCam-FIG-9

The LC display shows the max value, the min value, the differential value and the current value.

Area measurement:

The room perimeter is additionally shown on the LC display.

Area calculation:Laserliner-080-985-Distance-Master-LiveCam-
FIG-11

Volume measurement:Laserliner-080-985-Distance-Master-LiveCam-
FIG-12 Volume calculation:Laserliner-080-985
-Distance-Master-LiveCam-FIG-13

Point-to-point measurement: 

Laserliner-080-985-Distance-Master-
LiveCam-FIG-14

Angle function:Laserliner-080-985-Distance-Master-LiveCam-
FIG-15

The measurement results are determined automatically by the 360° inclination sensor.

Automatic height:

Laserliner-080-985-Distance-Master-LiveCam-
FIG-16

Pythagoras function 1:Laserliner-080-985-Distance-Master-LiveCam-
FIG-17

Pythagoras function 2: Laserliner-080-985-Distance-Master-LiveCam-
FIG-18

Pythagoras function 3:Laserliner-080-985-Distance-Master-LiveCam-
FIG-19

Trapezoidal function 1:Laserliner-080-985-Distance-Master-LiveCam-
FIG-20

Trapezoidal function 2:Laserliner-080-985-Distance-Master-LiveCam-
FIG-21

Triangular area measurement:

Laserliner-080-985-Distance-Master-LiveCam-FIG-22

Circular area measurement:

The circumference is additionally shown on the LC display.

Circular volumes:

Circular area is additionally shown on the LC display.

Stake out function:Laserliner-080-985-Distance-Master-LiveCam-
FIG-25

  • Select value
  • Change value
  • Save setting (optional)
  • Exit menu
  • To reach the target move the device in the direction of the arrow

Timer function:

Camera function:

Memory function:
The device has 50 storage locations.

Reference point displacement:
The set tolerance is calculated directly from the result of the measurement.

  • Select value
  • Change value
  • Save setting (optional)
  • Exit menu

Data transfer

This device has digital connectivity which allows wireless data transfer to mobile devices such as smartphones or tablets with a wireless interface. The system prerequisites for a digital connection are specified at
http://laserliner.com/info?an=ble
This device can generate a wireless connection to devices that are compatible with the wireless standard IEEE 802.15.4. The wireless standard IEEE 802.15.4 is a transfer protocol for Wireless Personal Area Networks (WPAN). The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, so es of interference as well as the transmit/receive properties of the terminal vice.

Enable / disable Digital Connection:

  • Enable / disable
  • Save setting (optional)
  • Exit menu

The digital connection is activated as soon as the device is switched on as the wireless system is designed to use very little electricity. A mobile device can link up to the active measuring device via an app.

Application (app)
An app is required to use the digital connection You can download the app from the corresponding stores for the specific type of terminal device: Laserliner-080-985-Distance-Master-LiveCam-FIG-32

After starting the app and activating the digital connection, a connection can be set up between a mobile device and the measuring device.If the app detects several active measuring devices, select the matching device. This measuring device can be connected automatically the next time it is switched on.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration
The measuring device must be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend carrying out calibration once a year. Contact your distributor or the UMAREX-LASER LINER service department.

Error code:

  • 204: Calculation error
  • 208: Overcurrent
  • 220: Replace the battery
  • 255: Received signal too weak256: Received signal too strong
  • 261: Outside the measuring range
  • 500: Hardware fault

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals