Laserliner 080-937 DistanceMaster Compact Pro
Function / Application
Laser distance meter with colour display
- Point laser for optical extension of the spirit level
- Horizontal and vertical angle display
- The slope memory allows angles to be easily transferred
- Measured data transfer via Bluetooth® interface
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Tampering with (making changes to) the laser device is not permitted.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
Laser outlet
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
Dealing with RF radiation
- The measuring device is equipped with a wireless interface.
- The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
- Umarex GmbH & Co. KG hereby declares that the DistanceMaster Compact Pro radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=ACH
Inserting batteries
Open the battery compartment and insert batteries according to the symbols. Be sure to pay attention to polarity.
DISPLAY
- ON/OFF button / READ: Transfer measured data via Bluetooth® interface
- Angle reference value setting / 3 sec.: change sensitivity
- Set gradient function
- Laser ON/OFF
- Change units of measure
- Acoustic signal generator ON/OFF / Hold function
- Calibration
- Slope direction
- Bluetooth® function activated Gradient function set
- HOLD: current measured
- value is held
- Unit of measurement %
- Digital bubble level
- Unit of measurement mm/m Angle reference set
- Battery charge
- Unit of measurement ° degrees
- Acoustic signal generator active Slope angle
- Laser active
- Horizontal vial
- Vertical vial
- Laser outlet
- Magnets
- Battery compartment (Rear)
- Measuring surface
- Measuring scale (DigiLevel Pro 40 / 60 only
Switching on and measuring
Make sure that the reference function is deactivated before measuring.
The DigiLevel Pro 40/60/80 can measure angles continuously to 360°.
- Switch the DigiLevel Plus on using the on/off switch (1).
- The slope angle is shown in the display (l). If slopes are measured overhead, the direction of display adjusts automatically.
- The current slope direction is also shown by the symbol (a).
Selection of unit of measurement
Button (5) allows the desired unit of measurement to be selected (° degrees, %, mm/m).
Calibration
-
Place the unit with its measuring edge (13) down on a straight surface and mark the positions of the unit‘s ends on the under-lying surface (see Fig. below). Switch on device (1). To access calibration mode simultaneously press buttons 1 and 3. – 1- appears on the display.
-
Then press the READ button (1). -1- flashes.
The display then changes to -2-. -
Now turn the unit around horizontally (end-for-end) by 180° such that its ends are positioned opposite where they previously were but again exactly at the underlying surface marks (reverse measurement).
Then press the READ button (1) again. -2- flashes.
The subsequent acoustic signal concludes the process.The unit is properly calibrated when it displays the same measurement value, i.e. the underlying surface‘s deviation from absolute level, in both positions (0° and 180°).
HOLD
Hold down the HOLD button (6) to keep displaying the current measured value.
Changing the angle reference value
With button (2), it is possible to transfer angles elsewhere.
To do so, set the device to the desired slope and press button (2). The
display then changes to „0.00°“, „REF“ appears on the display and the required
reference angle is set. The slope can now be transferred to other objects.
Press button (2) again to deactivate the angle reference.
Gradient function
Preset gradients of 1%, 2%, 3% and 4% can be set using the button (3). Keep pressing the button until the required value is displayed. The gradient function is switched off by pressing and holding button (3).
Acoustic signal
The acoustic signal can be switched on or off with button (6). When the angle of slope stands at 0°, 45°, 90° or the most recently stored value, this is indicated by an acoustic signal. When working with a changed angle reference value, the acoustic signal is activated on reaching the new reference value (0°, 45°, 90° display).
AUTO OFF function
In order to preserve the batteries, the measuring device switches off
automatically if it is left idle for 10 minutes. The backlighting switches off
after 1 minute.
Data transfer
The laser distance meter features a Bluetooth® function that enables wireless
data transfer to mobile devices with a Bluetooth® interface (e.g.
smartphones, tablets).
The system prerequisites for a Bluetooth® connection are specified at
http://laserliner.com/info?an=ble
The device can set up a Bluetooth® connection with Bluetooth 4.0 compatible
devices.
The range is set to a maximum distance of 10 m from the terminal device and
greatly depends on the ambient conditions such as the thickness and
composition of walls, sources of interference as well as the transmit/receive
properties of the terminal device.
- The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.
Application (app)
An app is required to use the Bluetooth® function. You can download the app
from the corresponding stores for the specific type of terminal
device:Make sure that the Bluetooth® interface of
the mobile device is activated. After starting the app and activating the
Bluetooth®* function, a connection can be set up between a mobile device and
the laser distance meter.
If the app detects several active measuring devices, select the matching
device.
This measuring device can be connected automatically the next time it is
switched on.
- The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mecha-nics, hard disks). With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republic of Germany. To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm away from the magnet.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it
produces accurate measurement results. We recommend carrying out calibration
once a year.
Technical Data
(Subject to technical changes without notice. Rev18W48)
Technical Data
(Subject to technical changes without notice. Rev18W48)
Distance measurement
Precision (typical)*| ± 2 mm
Inside measurement range| 0,1 m – 50 m
Angle measurement**
Measuring range| ± 90°
Resolution| 0,1°
Precision| 0,1°
Laser class| 2 < 1 mW
Laser wavelength| 650 nm
Operating conditions
| -10°C … 40°C, max. humidity 80% rH, no condensation, max. working altitude
2000 m above sea level
Storage conditions| -20°C … 70°C, max. humidity 80% rH
Radio module operating data
| Bluetooth LE 4.x interface; Frequency band: ISM band 2400–2483.5 MHz, 40 channels; Transmission power: max. 10 mW; Bandwidth: 2 MHz;
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
Automatic switch-off| 30-sec laser / 10 min device
Power supply| 2 x AAA 1.5 Volt batteries
Technische Daten (Subject to technical changes without notice)
Dimensions (W x H x D)| 43 x 110 x 27 mm
Weight (incl. batteries)| 100 g
- measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces.
** at max. 5000 lux
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ACH
SERVICE
Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932
638-333 info@laserliner.com
Umarex GmbH & Co KG Donnerfeld 2 59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>