Laserliner 080.936A DistanceMaster Compact Laser Range Finder Device Instruction Manual
- June 5, 2024
- Laserliner
Table of Contents
Instruction Manual
DistanceMaster Compact
|
---|---
**** Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.
Function / Application
Laser distance meter with color display
- For measuring length, area, and volume
- Min/Max function for determining diagonals, verticals, and horizontals
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise, invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture, or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
- Attention: Do not look into the direct or reflected beam.
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Tampering with (making changes to) the laser device is not permitted.
- Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
DISPLAY:
a Measurement point (reference) rear / front
b Display length / area / volume
c Measurement values / Measurement results Unit m / ft / inch / ‘ “
d Intermediate values / min/max values
e The bar diagram shows how well suited the reflection surface is for
measurement. This is particularly useful for measuring over long distances, on
dark surfaces, or on bright ambient light.
f Battery symbol
g Min/max continuous measurement
h Memory
I Malfunction/service required
KEYPAD:
- ON / Measure / min/max continuous measurement
- Length, area, volume / Memory
- Measurement point (reference) rear / front / Unit of measure m / ft / inch / ‘ “
- OFF / delete last measurement values
Inserting batteries (see Fig. A)
Open the battery compartment and insert batteries according to the symbols. Be
sure to pay attention to polarity.
Switch on, measure, and switch off:
Change unit of measure: m / ft / inch / ‘ “| Delete the last
measured value:
---|---
|
Change measurement point (reference):
Change measurement function:
Length measurement:
Area measurement:
Volume measurement:
Min/max continuous measurement:
The LC display shows the max value, the min value, and the current value.
Memory function:
Error codes:
Err101: Replace the battery
Err104: Calculation error
Err152: Temperature is too high: > 40°C
Err153: Temperature is too low: < 0°C
Err154: Outside the measuring range
Err155: Received signal too weak
Err156: Received signal too strong
Err157: Incorrect measurement or background is too bright
Err160: The device is moving too much to measure.
Important notices
-
The laser points to the location that will be measured.
No objects may get into the laser‘s line of measurement. -
The device compensates for the measurement of different room temperatures. Therefore allows the device a brief adaptation period when changing locations with large temperature differences.
-
The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
-
The measurement results of outdoor measurements may be influenced or falsified by rain, fog, and snow.
-
In unfavorable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.
-
Carpeting, upholstery, or curtains will not reflect the laser optimally.
Measure to flat surfaces. -
Measurements made through glass (window panes) can falsify measurement results.
-
An energy-saving function switches the device off automatically.
-
Clean with a soft cloth. Water may not be allowed to penetrate the housing.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents, or solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it
produces accurate measurement results. We recommend carrying out calibration
once a year.
Technical Data
(Subject to technical changes without notice. Rev18W46)
Precision (typical)* | ± 2 mm |
---|
Measurement range
(inside)**| 0,1 m – 25 m
Laser class| 2 < 1 mW
Laser wavelength| 650 nm
Operating conditions| -10°C … 40°C, max. humidity 80% RH, no condensation,
max. working altitude 2000 m above sea level
Storage conditions| -20°C … 70°C, max. humidity 80% RH
Automatic switch-off| 30-sec laser / 3 min device
Power supply| 2 x AAA 1.5 Volt batteries
Dimensions (W x H x D)| 43 x 110 x 27 mm
Weight (incl. batteries)| 100 g
- measuring distance up to 10 m with strongly reflective target surface and at room temperature.
The measurement deviation may increase by +/-0.2 mm/m for weakly reflective target surfaces.
at max. 5000 lux
EU directives and disposal**
This device complies with all necessary standards for the free movement of
goods within the EU.
This product is an electric device and must be collected separately for
disposal according to the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ACF
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com