Laserliner 080 836 LaserRange-Master Gi3 Distance Meter Instruction Manual

June 5, 2024
Laserliner

Laserliner 080 836 LaserRange-Master Gi3 Distance

MeterLaserliner-080-836-LaserRange-Master-Gi3-Distance-Meter-
product

Overview

Laserliner-080-836-LaserRange-Master-Gi3-Distance-Meter-
fig-1

How to use

Laserliner-080-836-LaserRange-Master-Gi3-Distance-Meter-
fig-2 Laserliner-080-836
-LaserRange-Master-Gi3-Distance-Meter-fig-3

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Function/Application

Laser distance meter – with green laser technology. Functions: distances, area, volume, min./max. measurement

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The following persons may use the device only when they are either supervised by a person who is responsible for their safety or have received instruction from this person on how to use the device:
    • Persons with restricted physical, sensory or mental abilities
    • Persons with no knowledge and/or experience in the use of the device
    • Children (under the age of 14)
  • The device and its accessories are not toys.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.

Safety instructions

Using class 2 lasers

Laser radiation
Do not stare into the beam!Class 2 laser < 1 mW · 515 nm EN 60825-1:2014/AC:2017.

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Tampering with (making changes to) the laser device is not permitted.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits values in accordance with EMC-Directive 2014/30/EU.

  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers –may apply. Electronic devices can potentially cause hazards
    or interference or be subject to hazards or interference.

  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Inserting batteries
Open the battery compartment and insert batteries (2 x type AAA) according to the symbols. Be sure to pay attention to polarity.

DISPLAY

  • a Measurement point (reference) rear/front
  • b Display length/area/volume
  • c Measurement values/Measurement results Unit m
  • d Intermediate values/min/max values
  • e Battery symbol
  • f Min./max. measurement
  • g Malfunction/service required

KEYPAD

  1. ON / Measure / OFF
  2. Length, area, volume, min./max. measurement Measurement point (reference) rear / frontLaserliner-080-836-LaserRange-Master-Gi3-Distance-Meter-fig-6

Measurement

Switch on, measure, and switch off:Laserliner-080-836-LaserRange-Master-
Gi3-Distance-Meter-fig-7

Change measurement point (reference):Laserliner-080-836-LaserRange-
Master-Gi3-Distance-Meter-fig-8

Change measurement function:Laserliner-080-836-LaserRange-Master-Gi3
-Distance-Meter-fig-9

Length measurementLaserliner-080-836-LaserRange-Master-Gi3-Distance-
Meter-fig-10

Area measurementLaserliner-080-836-LaserRange-Master-Gi3-Distance-Meter-
fig-11

Volume measurementLaserliner-080-836-LaserRange-Master-Gi3-Distance-
Meter-fig-12

Min./max. measurementLaserliner-080-836-LaserRange-Master-Gi3-Distance-
Meter-fig-13

Min. measurement
The LC display shows the lowest value (min.) and the current value.

Max. measurement
The LC display shows the highest value (max.) and the current value.

Important notices

  • – The laser points to the location that will be measured. No objects may get into the laser‘s line of measurement.
    – The device compensates the measurement for different room temperatures. Therefore allows the device a brief adaptation period when changing locations with large temperature differences.
    – The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
    – The measurement results of outdoor measurements may be influenced or falsified by rain, fog, and snow.
    – In unfavorable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.
    – Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.
    – Measurements made through glass (window panes) can falsify measurement results.
    – An energy-saving function switches the device off automatically.
    – Clean with a soft cloth. Water may not be allowed to penetrate the housing.

Error codes

  • Err08: Pythagorean measurement error
  • Err10: Replace the battery
  • Err11: Data transfer error
  • Err14: Calculation error
  • Err15: Outside the measuring range
  • Err16: Received signal too weak
  • Err26: Value outside the display range

Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

Technical Data

(Subject to technical changes without notice. 21W08)

Technische Daten (Technische Änderungen vorbehalten. 21W08)

Genauigkeit (typisch)*| ± 2 mm
Messbereich (innen)**| 0,3 m – 30 m
Laserklasse| 2 < 1 mW
Laserwellenlänge| 515 nm

Arbeitsbedingungen

| -10°C … 40°C, Luftfeuchtigkeit

max. 20 … 85% rH, nicht kondensierend, Arbeitshöhe max. 2000 m über NN (Normalnull)

Lagerbedingungen| -20°C … 70°C,

Luftfeuchtigkeit max. 80% rH

Automatische Abschaltung| 30 Sek. Laser / 3 Min. Gerät
Stromversorgung| 2 x 1,5V LR03 (AAA)
Abmessungen (B x H x T)| 40 x 110 x 24 mm
Gewicht (inkl. Batterien)| 90 g

  • measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for weakly reflective target surfaces.
  • at max. 5000 lux

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: http://laserliner.com/info?an=AIB.Laserliner-080-836-LaserRange-
Master-Gi3-Distance-Meter-fig-14

SERVICE

Umarex GmbH & Co. KG

Laserliner
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932 638-333 info@laserliner.com. Umarex GmbH & Co. KG Donnerfeld 2 59757 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: -333 www.laserliner.com.

References