WISI OH50A COMPACT HEADEND Basic unit Instructions
- June 5, 2024
- WISI
Table of Contents
WISI OH50A COMPACT HEADEND Basic unit
Safety and installation notes
-
Caution
The mains voltage must match the rated input voltage of the unit (230 VAC). -
CAUTION GROUNDING!!
Chassis must be grounded and disconnected from line power before any RF connections are made. Improper grounding may result in irreversible damage of the equipment. -
Connecting cable
- Lay the cable so that no-one can trip over it.
- Lay the cable with a downward loop so that any water condensing on it can drip on the floor instead of running into the unit.
Selecting the installation location
-
Excessive temperatures will reduce the operating lifetime of the unit. Don’t install the unit directly above or in the vicinity of radiators or heating systems where it would be subjected to thermal radiation or oil vapours.
-
Moisture Water dripping or splashing onto the unit will damage it. If there is condensation on the unit, wait until this has evaporated before switching the unit on.
-
Caution – danger! In accordance with EN 60728-1, the satellite antenna system must comply with the safety requirements with respect to grounding, potential equalisation, etc.
-
Service work Service work may be carried out only by qualified personal. Always disconnect the supply voltage before starting any such work.
Ambient temperature – Not greater than 50 °C. -
Thunderstorms Avoid carrying out service work on the antenna system during thunder-storms.
-
Caution – danger! Fuses may be replaced only by qualified personnel. Only fuses of the same type and rating may be used.
-
Batteries Do not throw exhausted batteries in the garbage. They must be disposed of separately.
All of our packing materials (cardboard boxes, packing notes, plastic films and plastic bags) can be recycled.
Connectors
Description of connectors
-
RF out = RF output; sum signal from the modules for injection into the distribution system
-
TP -20 = Test output -20 dB
-
FM in = Input FM amplifier, 25 dB
-
Handset OH 41 (Accessory) for setting all parameters
-
LED “Status” =
-
The global alarm status display shows the alarm level of all OH modules. It blinks the during communication with the modules.
The colour indicates the status of the modules (green: ok, red: alarm, yellow: first scan) -
In the bootloader mode (flashing red)
-
-
LED “Power” = – Status depends on the temperature of the OH50A and the power
input of all modules (green: ok, yellow: warning, red: alarm). -
LAN = – Interface to connect the unit to a ethernet network for remote control
-
USB update interface
-
Backside:
AC 230V = Mains connection -
Potential equalization terminal
Wall Mounting/ Hole Distances
For wall mounting of the OH50 chassis please use the supplied angle brackets, and fix it at both sides (see drawing). Use only the supplied screws (M4x6).
Wall Mounting versions
- If the cables are fed from above the basic unit choose this wall mounting version.
- If the cables are fed from below the basic unit choose this wall mounting version to maintain the min. bending radius of the coaxial cable.
Dust protection cover
To protect the basic unit during the mounting process from dust, please leave the carton as a cover at the front of the housing.
Assembly 19“-Rack
For 19”- mounting of the OH50 chassis please use the supplied angle brackets, and fix it at both sides (see drawing). Use only the supplied screws (M4x6).
Mounting 19″ angle brackets
-
Standard mounting (use front holes of the brackets)
-
Mounting for a bigger bending radius of the connection cables (use rear holes of the brackets)
-
Recommendation For operation all slots need to be equipped with a module, or covered with a blanking plate. Modules with a CI-slot need to carry the supplied covers, even without CA-module. This is necessary to assure proper air flow for cooling.
-
Short Circuit In case of a short circuit or an overload of the power supply, the system reboots permanently (hiccup mode). The front LEDs of the modules and the display of the handset start to flash. After elimination of the malfunction the power supply switches back to the normal mode.
Handset OH 41 (Accessory)
-
Standby
Mains connected to basic unit and the mode „Initializing the modules “has finished (see next page). Plug the handset into the socket on the basic unit. Press the ► key to enter the module menu and system menu. -
Modul menu
Press the ► key
▲▼ keys — Select module 1-14
► key — Move to parameter menu
◄ key — Back. -
Parameter menu
▲▼ keys — Select parameter
► key — Move to parameter sub-menu
◄ key — Back -
Parameter sub-menu
◄► keys — Select the digit to be changed Cursor blinks below the digit, e.g. 1894
If the permissible range is exceeded, the unit returns to the parameter menu
▲▼ keys — Change the value, e.g. change 1894 to 1834- Saving data: Data are saved automatically after leaving the parameter menu, or 60 seconds after the last entry.
Note: After programming remove the handset from the connector.
Initializing the modules
- Connect OH 50 A to mains power
- Connect the handset OH 41
- Modules are scanned in the background (can take up to 1 min!)
The description of the menu structures can be found in the related manual of the module.
The system menu of the basic unit
The menu item “System settings“ offers the parameter setup of the basic unit.
By selecting “System settings“ the user accesses the following OH 50 A system
parameters:
-
Update OH50A Insert USB memory stick > Select OH50A-File (Image)
-
Multi Update Mod Insert USB memory stick > Modules will be successively updated with latest software
-
UID License Code UID for Remote
-
License: 8C061251 (example)
-
The Web-UI (optional feature) is locked by default.
-
The UID License Code is needed to purchase and obtain a license key.
-
This key is to be entered via Web-UI or USB memory stick.
-
LIC Load OH50A Insert USB memory stick > Search for Unlock code and activate it
-
LIC Load Module Insert USB memory stick > Search for License-File and transfer it to selected module.
-
LIC to: 2 OH77 (example) > Insert USB memory stick
-
NIT Load Module NIT Load (Import external NIT) NIT to: 2 OH77 (example) > Insert USB memory stick
-
CfgLoad Insert USB memory stick > config. file is uploaded, the modules are configured accordingly (the modules have to remain at the same plug-in positions as in CfgSave)
-
CfgSave Insert USB memory stick > the configuration of all modules is described in the config. file
-
StatSave Insert USB memory stick > status (e.g. PLL-lock) of all modules is decribed in the status file
-
IP-Addr IP address setting, e.g. 192.168.000.100
-
ETH-NetMask Subnet-Mask, e.g. 255.255.255.000
-
ETH-Gateway Gateway address setting, e.g. 192.168.000.001 (router/server for internet)
-
Port Standard-Port for http = 80
-
FM-Att FM-Attenuation
0…30 dB (attenuation at the FM input)
Out-Att Out-Attenuation
0…15 dB (attenuation at the FM output) -
I-Supply Current
I: <8750 mA (power consumption of installed modules) -
SW-Version Displays the current software version of OH 50 A
-
HW-Version Displays the current hardware version of OH 50 A
-
BL-Version Displays the current boot loader version of OH 50 A
-
Factory Reset Reset OH 50 A to delivery status (all settings are deleted, the activation key remains)
-
Restart OH50A Software-Reset OH50A
-
Restart System Reset OH50 Headend (all modules)
-
Restore Web SW Restore the factory default settings of the web interface
With the ◄ key, you step back from the “System settings” menu to the module selection menu. When the entry “system settings” is selected in the module selection menu and the ◄ button pushed afterwards, the device will move to standby immediately. Saving changes: By leaving the “System settings” menu. Without any user setting the standby display appears after 60 seconds, settings are not being stored.
Update function basic unit and modules
System recovery
Press the buttons ◄ ► simultaneously when power supply is applied. Then press
► button and choose Backup SW “yes”, to start emergency application.
Update functions in the OH 50A menu “system settings”
The following steps are required for an software update:
- Connect handset to the base unit, the handset must display the standby message.
- Plug an USB memory stick into the USB port.
- The following options are selectable:
- Multiupdate Mod All modules are updated automatically, if a newer software is available on the USB memory stick. The update process starts. After the update the modules will be rebooted.
- completed, the device will be rebooted. Be sure that a file with the name “OH50A__HW_Vx_xx_SW_Vx_xx.bin” is only present once on the USB memory stick.
- Cfgload The settings from a configuration file on the USB memory stick are uploaded into the modules. Please note: the module types and their slot order have to be the same as those in the configuration file!
- Cfgsave The display shows “Checking file”. The current configuration of the modules is uploaded and saved to the USB memory stick (Config.OH50A_2014_05_01_14_15).
If an module update fails, the module remains in the bootloader. This is displayed on the web interface and on the handset. The module can be programmed again from the web interface. To program the module with the handset “Multidate Mod.” has to be selected in the menu “System Settings” .
Update function Basic unit and modules
Note: You will find the latest firmware here: http://wisi.de/en/business/products/compact-headend/
- Don’t interrupt the power supply of the device during the update
- The used USB memory stick needs to be FAT32 formatted and must not be removed during the update is running.
- It is not allowed to change the names of the update or config files.
- The update or config files must be located in the root directory of the USB memory stick.
System configurations example
Channel processing for analogue and digital satellite programmes
The WISI COMPACT HEADEND permits the processing of analogue and digital TV
programmes in networks.
Adjusting the system levels
The output level must always be set to the permissible system output level.
For every module the output level can be adjusted by the parameter menu “Out-
Att”.
Default factory IP parameter values and SNMP community strings
- IP address 192.168.0.20
- Netmask 255.255.255.0
- Gateway 192.168.0.1
- DHCP disabled (DHCP functionality is disabled)
- E-Mail disabled
- HTTP Port 80 (standard)
- SNTP disabled (time syncronisation server disabled)
- Sync Install Time 24 (time syncronisation all 24 hours)
OH-Setup Windows Tool
The WISI tool named “WISI OH-Setup” (filename ‘OHSetup.exe’) has to be copied
on a PC with operating system Windows XP / 7. An ethernet connection between
this PC and the OH50A unit is required. Start the program. Complete the four
fields with the correct Ethernet MAC Address of the OH50A unit (see label at
OH rack: 00-03-98-…) and the wanted IP parameters (IP-Address, Network mask,
Gateway).
Now press the button “Assign” for setting these parameters. The tool checks
first, if the IP address is valid and still free. Afterwards the IP parameters
of the OH50A unit will be set and stored. Please check the message in the
lower status line of the window, if the assignment has succeeded or not.
OH 41 Handset
While the handset is being used (Modul Menü) the web interface is disabled and displays “Handset in use”. After 60 seconds the handset automatically returns to the standby display. The web interface is now enabled again. The handset has higher priority than the web interface.
Activation of the web interface:
The Web UI of the newly purchased OH 50 A is locked. After login with the
username “user” the following message will appear:
WISI converts the Unique ID (UID) into an unlock code for a license fee:
After entering the unlock code the device is permanently unlocked.
Web Interface
An ethernet connection between the PC (with an installed webbrowser) and the OH50A unit is required. One of the following webbrowsers are recommended:
- Internet Explorer from v8, v9 recommended
- Firefox from version 15
- Safari from version 5.1.7
- Opera from version 12.15
- Google Chrome from version 27.0.1453.116
- In order to set up the chassis via web interface, the current IP address of the OH50A module has to be known. Setting the address is possible with the handset
- Read write access: Log in under user name “user”. Enter password (“wisi” is used as factory setting). Read only access: Log in under user name “read”. No password needed.
- Select tab “Network settings” under “OH50A”.
- If changes in the IP parameters are necessary, the button “save” has to be pressed.
- The browser is being redirected to the new address.
The tab “E-Mail setup” allows up to 3 addresses to which fault reports
concerning the modules or the OH 50A base unit are sent (alarm). The OH50A can
request server-side authentication (user name, password).
Please note: Transmitted data is not encrypted.
The tab “update” gives the abillity to update the modules software. The
software has to suit the type of module and the hardware version has to match.
Modules of the same type ca be programmed simultaneously. Select all modules
of the same type, select the software on the computer and choose
“program Module”. The programming process for all modules is being started.
Extended updates for the MPEG decoder etc. (filename.zli) as well as the NIT
table of a module (filename.nit) can be transferred through the website. A new
website can be programmed as well. The activation code (*. Onl file) for the
modules (ex.: to utilize the external Nit) can be transmitted in the same way.
Select “Websoftware update”, choose websoftware (filename.tar) and select
“program Module”. Run a firmware update by selecting “OH50A Firmware” > Datei
laden > “program Module”. OH50A reboots. To save the module configuration
select the checkboxes for the modules and click “save configuration”. To
upload config files to the modules select the file on your PC and click “load
configuration”. You do not have to tick the checkboxes. The sequence and type
of the modules in the chassis has to correspond to the sequence of the modules
on the update file.
Specifications
-
Booster / Booster amplifier
Frequency range TV 47–862 MHz -
Frequency range FM 87,5–108 MHz
-
Output impedance 75 Ω
-
Output return loss > 14 dB
-
Output level 110 dBμV
-
Output attenuator 0-15 dB / 1 dB steps
-
Input level (FM) 70–100 dBμV
-
FM attenuator 0-30 dB / 1dB steps
-
CTB / CTB > 60 dB
-
CSO / CSO > 60 dB
-
Test output – 20 dB
-
Power supply
-
Input voltage 180… 265 VAC (47… 63 Hz)
-
Max. power consumption < 185 W
-
Efficiency ≤ 89 %
-
Output voltage 12,5 V
-
Output current 12 A
-
LNB power 12,5 V 1,2 A
-
PFC / PFC EN 61000-3-2
-
Ethernet (“LAN”) / Ethernet (‚LAN’)
-
Interface 10/100 Base-T, RJ-45 Buchse / female jack
-
2 LEDs green for link/activity, yellow for speed
-
Protocol
- Data Link Layer Ethernet
- Network Layer IP, ICMP
- Transport Layer UDP, TCP
- Application Layer DHCP
(for automatic IP address assignments),
(UDP Port 123, for time and date ), SNTP, RFC 4330 HTTP (Webserver-Zugriff / web server access)
-
Speed 10/100 Mbps
-
Duplex / Duplex half-duplex/full-duplex, autosensing
-
IP Version / IP Version 4
Remote Bus (OH backplane, communicates with all connected OH modules)
- Interface board connector, 20 pins, RS-485
- Protocol Module ASCII
- Speed 115 kbaud
- Duplex half-duplex
General specifications
- Dimensions 443 (19“) x 132 (3HU) x 351 mm
- Connectors
- FM-input 1 x F-connector
- RF-output 1 x F-connector
- Test-output 1 x F-connector
- Handset control RJ 11
- Software update USB-A
- Remote connection RJ 45
- Operating temperature range – 20 °C to + 50 °C
- Nominal temperature range + 5 °C to + 50 °C